SIEMENS-RDE100-Room-thermostat-Operating-Manual-FEATURED

SIEMENS RDE100 Room Thermostat Operating Manual

SIEMENS-logo

SIEMENS RDE100 Room Thermostat

SIEMENS-RDE100-Room-thermostat-Operating-Manual-PRODUCT

Operating Instructions

RDE100.. – the room thermostat that allows you to set the ideal room temperature at the time you want. There are several switching patterns available that can be set to your specific needs

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-2

Display

1. Display
SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-3Indicating that batteries need to be replaced (only with battery-powered version)  

 

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-13Digits for time

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-4

Frost protection (heating) is active

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-14Morning: 12-hour

format

Afternoon: 12-hour format

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-5Auto Timer mode SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-15Confirmation
View and set Auto time switch SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-16Room temperature in degrees Fahrenheit
SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-6Comfort mode SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-17Room temperature in degrees Celsius
SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-7Economy mode SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-18Button lock activated
SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-8Escape SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-19Display of room tem- perature, setpoint, etc.
SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-9External input enabled SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-20Heating ON
SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-10Permanent setpoint                         setting SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-21Weekday

1 = Monday

7 = Sunday

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-11Day and time setting                       SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-21Timer bar
SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-12Holiday mode setting SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-22Current room temperature
2. Change operating mode
3. Set
4. OK
5. Decrease value
6. Increase value
7. Battery holder

Do you want to adjust the time and day? 

set ok

+

mode

Proceed as follows:

·        Press set and selectSIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-23

·        Press ok and the time flashes for setting

·        Press + or to adjust the time

·        Press ok to confirm

·        The weekday flashes, press + or to select the desired day

·        Press ok to save the value

·        Press mode to exit or wait for the program to exit automatically

Do you want to lock the buttons?

mode Press and hold mode for at least 7 seconds to activate a button lock. Repeat to unlock.

The unit operates normally when the buttons are locked, but no changes are possible while the buttons are locked.

Are your rooms too warm/too cold?

+

ok set

mode

Press + or to increase or decrease the room temperature setpoint in increments of 0.5 °C / 1 °F. Proceed as follows:

·        Press + or to adjust the setpoint temporarily. This adjustment is reset as soon as the operating mode changes.

·        Press ok, set or mode to save the value or wait for the program to exit automatically

·        To lock the setpoints, use parameters P06 and P08.

Do you want to change the operating mode?

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

!

The thermostat provides Comfort mode, Economy mode, and Auto mode. Changeover between the operating modes can be made manually by pressing mode.

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-6Comfort mode is the permanent (24 h) selection of Comfort. Select this mode to maintain Comfort temperature permanently without any time switch. It is used during occupancy periods, for example.

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-7 Economy mode is the permanent (24 h) selection of Economy. Select this mode to maintain the Economy temperature permanently without any time switch.

It is used during non-occupancy periods, for example at night.

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-23AUTO In Auto timer mode, operating modes (Comfort, Economy) are changed automatically according to the time switch set.

Note:

Frost protection is a function always active in the background. As soon the room temperature falls below 5 °C, the unit automatically activates the

heating .

Do you want to set permanent temperature setpoints?

set ok

+

mode

 

 

!

·        Press set and selectSIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-24

·        Press ok to confirm

·        Press mode to select an operating mode, Comfort or Economy

·        Press + or to adjust the setpoint permanently.

·        Press ok to confirm

·        Press mode to exit or wait for the program to exit automatically

Note: This permanent setpoint is used during Auto timer mode.

Energy saving tips without sacrificing comfort

  • Select Auto timer mode during the heating period, and set the time switch according to your normal habits at home
  • Select Economy mode or Holiday mode for long periods of non-occupancy and during summer period

Do you want to set your Holiday mode?

set ok

+

mode

 

 

 

 

 

!

Use the Holiday mode to set the thermostat to a constant temperature while absent.

·        Press set and selectSIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-25

·        Press ok to confirm

·        Press + or to adjust the temperature setpoint

·        Press ok to confirm

·        Press + or to adjust the number of days for holidays (Note: 0 = Holiday mode OFF)

·        Press ok to save the value

·        When Holiday mode is activated, the remaining days are displayed on the screen

Note: If you press mode while Holiday mode is active, the function is turned off and the SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-25 symbol disappears.

If the Comfort and Economy setpoint values are both locked, the lowest locked setpoint value is the Holiday mode setpoint value. You can adjust the setpoint temperature from 5 °C up to the lowest locked setpoint value.

Do you want to enter your own time switch?
Option 1: Time switch with individual day selection (P11=0)

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-1

Option 2: Time switch with the same 7 day selection (P11=1) 

set ok

+

mode

You can set all the 7 day time switches at the same time.

Example:

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-26

 Visible bars: Control to Comfort temperature

‚ Invisible bars: Control to Economy temperature

 

Proceed as follows:

1)  Set the parameter (P11=1). Please refer to the section “Do you want to change parameters“.

2)  Press set and select SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-5

3)  Press ok to confirm.

4)   Time switch for period Mon (1) – Sun (7) is displayed.

5)  Press ok to initiate time programming.

 

During programming step:

6)  Press mode to select an operating mode, (Comfort or Economy) or

7)  Press + or to adjust time setpoint by 15 minutes for the selected mode.

 

8)  Press ok to save the time switch.

9)  Press mode or wait for the program to exit automatically.

 Option 3: Time switch with 5-2 day selection (P11=2)

set ok

+

mode

You can set Monday – Friday time switch at once and Saturday – Sunday time switch at once.
Example:SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-26
 Visible bars: Control to Comfort temperature
‚ Invisible bars: Control to Economy temperature
Proceed as follows:
1)  Set the parameter (P11=2). Please refer to the section “Do you want to change parameters“.

2)  Press set and select SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-5

3)  Press ok to confirm.
4)   Time switch for period Mon(1) – Fri(5) is displayed.
5)  Press + or to select the period, Mon (1) – Fri( 5) or Sat (6) – Sun (7).
6)  Press ok to confirm the selected period and initiate time programming.
During the programming step:
7)  Press mode to select an operating mode, (Comfort or Economy) or
8)  Press + or to adjust the time setpoint by 15 minutes for the selected mode.
9)  Press ok to save the time switch.
0)  Repeat the steps 5-9 for the other period if necessary; or
1)  Press mode or wait for the program to exit automatically.

The factory default for 7-day time switch

Default value Day/s Comfort mode Economy mode
Mo (1) – Fr (5) 6:00 – 8:00 hr

17:00 – 22:00 hr

22:00 – 6:00 hr

8:00 – 17:00 hr

Sa (6) – Su (7) 7:00 – 22:00 hr 22:00 – 7:00 hr

Does symbolSIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-27 appear on the display?
(Only with battery-powered versions) SymbolSIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-27 is displayed when the batteries are low. Replace them  with 2 new alkaline batteries type AAA. Proceed as follows:

  • Get 2 new alkaline batteries type AAA
  • Remove the battery holder, then the batteries, insert the new batteries and, within 1.5 minutes, replace the battery holder
  • Ensure the exhausted batteries are disposed of correctly, in compliance with environmental requirements

Do you want to change the parameters?

+

ok mode

If you want to change control parameters, proceed as follows:

·        Press + and simultaneously for 5 seconds

·        Release them and parameter “P01” is displayed on the bottom segment

·        Press + or to scroll to the parameter that needs to be adjusted

·        Press ok to select this parameter

·        Press + or to adjust the value

·        Press ok to confirm the adjusted value

·        Press mode to exit the parameters without saving or wait for the program to exit automatically

Parameter list

Parameter no. Description Setting range (default)
P01 Time format 1 = 24:00 hours (default)

2 = 12:00 AM/PM

P02 Selection of °C or °F 1 = °C (default) 2 = °F
P03 Standard temperature display 1 = room temperature (default)

2 = setpoint

P04 Temperature sensor calibration -3…3 °C

Step 0.5 °C

(-6…6 °F, step 1 °F)

Default: 0 °C

P06 Comfort setpoint lock 0 = OFF (default)

1 = ON è locked according to setting in permanent temperature setpoint

P08 Economy setpoint lock 0 = OFF (default)

1 = ON è locked according to setting in permanent temperature setpoint

P09 Buzzer 0 = OFF

1 = ON (default)

P10 Show frost protection icon 0 = OFF (default) 1 = ON
P11 Time switch type for auto timer 0 = Individual Days (default)

1 = All 7 days 2 = 5/2 days

P12 Periodic pump run 0 = OFF (default) 1 = ON
P14 X1 External input (only for RDE100.1) 0 = No input

1 = External sensor 2 = Digital Input

P15 Temperature limitation (only for RDE100.1) 0 = OFF (default) 1 = ON
P16 Max limitation temperature for underfloor heating (only for RDE100.1) 25…60 °C, step 1 °C or 77…140 °F, step 1 °F Default: 30 °C
P17 Window contact features (only for RDE 100.1) 0 = Normally Open Contact (default)

1 = Normally Closed Contact

P21 Button scanning rate for the capacitive buttons

(RDE100.1 only)

Note: a shorter scanning rate means shorter battery life.

0.2 = 0.25 s

0.5 = 0.5 s

1.0 = 1.0 s (default) 1.5 = 1.5 s

P22 Reload factory settings 0 = OFF (default) 1 = reload
P23 Software version information No adjustment possible
P78 Control behavior 0 = On/Off, 1.0K

1 = On/Off, 0.3K 2 = TPI fast

3 = TPI medium

4 = TPI slow (default)

P89 Forward shift on max 0, 0.5,…24 h

Default: 0 h

P90 Early shutdown max 0, 0.5,…6 h

Default: 0 h

Disposal of electrical and electronic equipment

SIEMENS-RDE100-Room-thermostat-Operating-Manual-FIG-28
The symbol with the crossed-out waste container means that electrical and electronic products and batteries may not be disposed of in the normal household waste. They must be placed in separate collection and recycling containers according to the applicable laws. Please also refer to any applicable national labeling requirements. Proper disposal helps save valuable resources and prevents potentially harmful effects to people and the environment. Spent batteries and accumulators that can be removed from old devices for disposal, must be removed and placed in the indicated disposal channels. You are responsible for deleting any personal data from old devices for disposal. The registered manufacturers or distributors of electrical and electronic devices have established a common system for returning old devices. Suppliers of electrical devices must accept the returned devices at no charge. You can return old devices to the original sales location or to recycling or collection centers for old electrical devices. Please contact your regional or municipal offices/authorities for information on recycling centers or collection centers for old electrical devices.

REFERENCE:

DOWNLOAD MANUALS:

SIEMENS RDE100 Room thermostat Operating Manual

OTHER MANUALS:

SIEMENS RDE100 Room Thermostat Product Specifications Guide

SIEMENS-logo

SIEMENS RDE100 Room Thermostat Operating Manual


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)