SALUS EP110 Single Channel Programmable Thermostat
INTRODUCTION
Programmable timers EP110, EP210, and EP310 are used to switch ON/OFF the heating system, the hot water or any electronic device like pumps or lights as needed. It works by controlling with programmed schedules (24H or 5-2 schedule types) which contain 3-time programs each.
PRODUCT COMPLIANCE
EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU.
Please check www.saluslegal.com for the full information.
SAFETY INFORMATION
Use in accordance with the regulations. Indoor use only. Keep your equipment completely dry. Disconnect your equipment before cleaning it with a dry towel. The unit is to be used for the control of room temperature inside the house.
INSTALLATION
Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely dry.
This product must be installed by a competent person and in accordance with all the EU and national regulations.
Technical data
EP110 | EP210 | EP310 | |
Power Supply | 230 V AC | 230 V AC | 230 V AC |
Max load | 3 (1) A | 3 (1) A | 3 (1) A |
Output | NO / COM / NC
volt free |
2 x SPDT 230V AC | 3 x SPDT 230V AC |
Number of channels | 1 | 2 | 3 |
Dimensions [mm] | 120 x 98 x 27 | 120 x 98 x 27 | 120 x 98 x 27 |
Button | Function |
MODE | Select operating mode (ON, ONCE, AUTO, ADV, OFF) |
+HR | Activate/deactivate BOOST function |
![]() |
Turn on the LCD backlight |
Press for 3 sec to activate HOLIDAY mode | |
![]() |
Increases the selected setting |
![]() |
Decreases the selected setting |
![]() |
Select a clock or program setting |
![]() |
Sets a clock or programme setting |
![]() |
Reset to Factory settings |
LCD display icon description
- Device operation (animated icon)
- Number of hours for the BOOST function
- ON/OFF indicator
- Work mode
- AM/PM
- Holiday mode
- Clock
- The day of the week
- Program number
- 1. Zone I operation mode
- Day of the week
- Program number
- ON/OFF indicator
- Zone II operation mode
- Zone II work status
- AM/PM
- Number of hours for the BOOST function for Zone II
- Number of hours for the BOOST function for Zone I
- Zone I work status
- Clock
- Holiday mode
- Zone I operation mode
- Zone II operation mode
- Zone III operation mode
- Program number
- ON/OFF indicator
- Holiday mode
- AM/PM
- Number of hours for the BOOST function for Zone III
- Zone III work status
- Zone I work status
- Number of hours for the BOOST function for Zone II
- Zone II work status
- Number of hours for the BOOST function for Zone I
- Clock
- Day of the week
Jumpers settings
The parameters can be changed using the jumpers on the back of the device.
Note: Disconnect the power supply before working with the device.
Note: After changing the settings, it is necessary to reset the device using the button.
Wiring diagram
All wire connectors are located on the back of the device. To remove the cover, loose two screws located at the bottom of the device and then remove the back of the housing.
Note: Disconnect power supply before working with the device.
Setting time and date
Operation modes
There are 5 different work modes available. Using MODE button, you can change modes directly according to the following sequence:
- ON mode
- ONCE mode
- AUTO mode
- ADV mode
The ADV mode can be activated if the ONCE or AUTO mode is selected when it is activated - OFF mode
Programming EP110 controller
You can create 3 independent time schedules. There are 2 work models to choose from:
- business days + weekends (5-2)
- each day separately (24 hours)
The controller works by default in working days + weekend mode (5-2).
To set each day separately (24 hours), change the jumper position according to the diagram on the previous page.
Programming EP210/EP310 controller
You can create 3 independent time schedules for each zone. There are 2 work models to choose from:
- business days + weekend (5-2)
- each day separately (24 hours)
The controller works by default in working days + weekend mode (5-2).
To set each day separately (24 hours), change the jumper position according to the diagram on the previous page
HOLIDAY mode
Holiday mode is used to disable all controller outputs for a specified number of days (up to 31 days).
When HOLIDAYS mode is active, aircraft icon will appear on the display.
BOOST Function
BOOST function extends the active program time to 1-9 hours. Press the +Hr button to activate BOOST mode (each press of the button extends the active program by 1 hour
Factory Settings
If you made a mistake, want to change controller parameters or return to its factory settings, you can reset the controller with button
SALUS Controls plc
SALUS House Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP UK.
SALES: T: +44 (0) 1226 323961
E: [email protected]
TECHNICAL: T: +44 (0) 1226 323961
E: [email protected]
Issue Date: Feb 2014
Maintaining a policy of continued product development SALUS Controls plc reserves the right to change the specification, design, and materials of products listed in this brochure without prior notice. SALUS Controls is a member of the Computime Group 00089.
REFERENCE:
Download Manual:
SALUS EP110 Single channel programmable Thermostat Quick Guide
Other manuals:
SALUS EP110 Single Channel Programmable Thermostat Installation Manual
SALUS EP110 Single Channel Programmable Thermostat Quick Guide
Leave a Reply