Roth Minishunt Wireless Thermostat
Mounting
Wiring
- Connect to 230V power, Controller is ready for pairing with the sensor Please see the thermostat/sensor operation manual.
- B: 230V pump output, max. load 0,5 A. Connect “brown” to L and “blue” to N. Cables must be secured.
- C: Actuator. Connect “brown” to L and “blue” to N. Cables must be secured. Use Roth Project actuators 230V 1 Watt, HVAC no. 7466275430.
Glass fuse WT 6.3 A (5 x 20 mm). Turn off 230V power before replacing
Connection
Roth room thermostat
- Remove screw and slide backplate off.
- Insert batteries (included), be aware of +/- polarity.
- Mount backplate on the wall (screws not incl.) thermostat slides onto back plate
Pairing/registering the thermostat. All connections must be made to the Controller (pump, actuator before start-up. Please see controller manual for details. Press the registration button on the left side of the control unit (see picture 5) and then press the registration button on the room thermostat (see picture 6). The temperature is now shown in the display.
Attention! Do not press the buttons on the front of the thermostat whilst pushing the pairing button on the rear (see picture 6).
Operation of thermostat