Rointe ST.2 Digital Programmable Thermostat
INTRODUCTION
This thermostat is designed to aid in the comfort of your home by providing timed regulation of your heating system. The thermostat is designed to receive temperature input signals from the following sensors:
- Air sensor located inside thermostat.
- Floor sensor installed in floor (see heater instructions for details).
The thermostat is not a safety device and should only be used with Rointe heating products. In order to avoid damaging your flooring the correct floor type must be selected during the thermostat programming process.
WARNING – Important safety note
This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should always isolate the power supply before attempting to install or repair the thermostat. The thermostat should not be put into operation unless you are certain that the entire heating installation complies with current general requirements for electrical installations. Electrical installation must be in accordance with the latest wiring regulations.
LOCATION
The thermostat should be installed inside a single electrical wall box that is at least 35mm deep. For optimal performance the thermostat should be located in an area with good ventilation. It should not be beside a window/door, in direct sunlight or above heat generating device (e.g. radiator or TV). The thermostat is designed for operation between 0ºC and 55ºC with relative humidity less than 80%.
INSTALLATION
Separate the front housing of thermostat from wall module:
- Unscrew both closing screws (bottom of thermostat) until they will not turn any further.
- Release front housing by gripping lower half of outer frame and pulling outwards.
- Place front housing somewhere safe.
- Run all wires to the wall box. Check to ensure that you have included the following:
- Power (Live and Neutral)
- Heater (Live and Neutral or Switch Live only)
- Floor sensor
- Pull wires through wall box and complete terminal wiring.
IMPORTANT: Ensure that multi stranded wires are fully inserted into the terminals and secured tightly. Any loose strands should be trimmed as they could cause a short-circuit. If connecting more than two heaters, an electricial junction box will be required.
Note: Always ensure that the sensor cable is installed in a separate conduit to the power supplying the thermostat and heating system.
MOUNTING STEPS
- Release the front cover by inserting a screwdriver into bottom crack.
- Take the backing plate apart according to the following diagram.
- Mount the backing plate on the wall socket using a screwdriver.
- After connecting the wires (see connection diagram), mount the thermostat to the backplate and remount the cover and frame.
CONNECTION DIAGRAM
ELECTRICAL SPECIFICATION
- Supply voltage: 230V +/- 10% at 50Hz
- Thermostat is not designed for use with intermittent power supply.
- Maximum Switch Load: 16A resistive
- Insulation Class: II
- IP20
- Standards: EN60730-1 & EN60730-2-9
DISPLAY SYMBOLS
DIMENSIONS
USER OPERATION
- On / Off
- Press to increase or decrease the temperature.
- Press hold for 5 seconds at the same time to adjust time. Press to choose object to adjust; Pressto increase or decrease your set values; Press “ ” to confirm and exit.
- Press key to select manual mode or clock-controlled program mode.
- It displays the time or the temperature alternatively, and it displays the measured temperature directly.
- When you press at the same time and hold for 5 seconds, the thermostat will be locked/unlocked. When it is locked, no operation can be carried out until it is unlocked.
PERIOD PROGRAMMING
Press key and hold for 5s to start programming.
SENSOR FAILURE
- E0: Built-in sensor short-circuited or disconnected.
- E1: External sensor short-circuited or disconnected.
When shows E0/E1 error, thermostat must be checked until the error is eliminated.
ADVANCED SETTINGS
When the thermostat is powered off, press keys simultaneously.
- 1ADJ: Temperature calibration
Press key to adjust present checked value, adjustable scale: ±9,9ºC
Press key to enter to next step. - 2SEN: Sensor mode
Press key to choose sensor working mode IN: built-in (air). OUT: floor sensor. All: both sensors, in this mode floor sensor will be the limit sensor.
Press key to enter to next step. - 3LIT: Max. floor temperature
Press key to set the temperature floor. Range: 5~60ºC
Press key to enter to next step. - 4DIF: Sensor tolerance
Press key to set your sensor tolerance. Range: 0,5~10ºC
Press key to enter to next step. - 5LTP: Anti-frost mode
Press key turn on/off.
If you activate it, the anti-frost will start when the thermostat is off.
Press key to enter to next step. - 6PRG: Set program day mode
Press key to choose your program day cycles: 5/2 days; 6/1 days; 7 days.
Press key to enter to next step.
Not applicable to electric systems.
For Rointe electric systems, please skip this step. - 7RLE: Potential-free output and main power output in same/different way
Press key to change the present linkage state. 00: in same way; 01: in different way.
Press key to enter to next step.Not applicable to electric systems.
For Rointe electric systems, please skip this step. - 8DLY: Delay time of potential-free output
Press key to change the present linkage delay time.
Range: 0~5min
Press key to enter to next step. - 9HIT: Max. air temperature
Press key to set the temperature air.
Range: 35~90ºC
Presskey to enter to next step. - AFAC: Reset to factory settings
Press key for 5 seconds until the screen shows Range: 35~90ºC
Switch thermostat off to save your settings.
GUARANTEE
Rointe guarantees this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of two (2) years from the date of purchase by the consumer. If at any time during the guarantee period the product is determined to be defective, Rointe shall repair or replace it, at Rointe’s discretion.
If the product is defective, please either,
- return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it or
- contact Rointe. Rointe will determine whether the product should be returned, or replaced.
This guarantee does not cover removal or reinstallation cost, and shall not apply if it is shown by Rointe that the defect or malfunction was caused by damage which ocurred while the product was in the possession of the end user.
Rointe’s sole responsibility shall be to repair or replace the product within the terms stated above.
ROINTE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESSED OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY ECPRESS WARRANTY ROINTE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING WARRANTIES FOR COMMERCIAL USE OR FIT FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE TWO-YEAR DURATION OF THIS WARRANTY.
This Warranty does not affect your statutory rights.
Please register your product at: www.rointe.co.uk
REFERENCE
DOWNLOAD MANUAL:
Leave a Reply