Using a TOUCH SCREEN

Please take a moment to try out your touch screen itself. To select a function on the touch screen, place your finger on the main temp display and give a short firm push. Try a “tap” of the finger or stylus. Your input must last long enough for the system to determine it is not an accidental ‘bump’. Using the stylus is more comfortable for some users. Again allow the system enough time to recognize your inputs. When you are comfortable with touch inputs, proceed.Ritetemp-8085C-Programmable-Thermostat-FIG.1

Basic Screens

  • The MODE SWITCH of the 8030 must be in the HEAT or the COOL position to access all control functions. The 8030 Thermostat has 3 basic screens.
  • The HOME screen is displayed when unit is operating your system. Touching the Ritetemp- 8030-programmable- Thermostat -2 will always return you to this screenRitetemp-8085C-Programmable-Thermostat-FIG.2

MENU screen

Displayed when the MENU button is pressed from the HOME screenRitetemp-8085C-Programmable-Thermostat-FIG.3

PROGRAM screen

Displayed when the PROGRAM button is pressed from the HOME screenRitetemp-8085C-Programmable-Thermostat-FIG.05

Configure

  • Press MENU, from the home screen, to configure the thermostat.
  • Set day of the weekRitetemp-8085C-Programmable-Thermostat-FIG.5Touch the Day of the week area to cycle through the days of the week to select the current day.
  • Set time of day –Ritetemp-8085C-Programmable-Thermostat-FIG.6
  • Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for a faster setting.
  • Set oC -oF displayRitetemp-8085C-Programmable-Thermostat-FIG.7
    Touch the oF and it will toggle to oC.
  • Set audible chirp –Ritetemp-8085C-Programmable-Thermostat-FIG.8
    Touch the musical note icon to select the chirp or no chirp.
  • Return HOME by touching the home icon.Ritetemp-8085C-Programmable-Thermostat-FIG.9

Auto-run

  • This Thermostat comes preprogrammed with an Energy- ~ Star™ approved program. This program is recommended by ~ the EPA for energy efficiency.
  • We strongly recommend that you Auto-Run this program for one week, and see if it works for you. If it does not fit your needs you can always input a custom program.
  • To Auto-Run the Energy-Star™ program, select HEAT or COOL with the mode switch. The unit is now running the Energy-Star™program.
  • The clock is displayed on the left. The ambient temperature is displayed in the center of the LCD touchscreen. The TIME SLOT icon indicates the
  • TIME SLOT is active in the Energy-StarTmprogram.
  • The programmed temperature is shown on the lower right. For program details refer to the Energy-Star™ program chart below.Ritetemp- 8085C-programmable- Thermostat -30

Program

Press PROGRAM, from the HOME screen, to go to the program screen –
Select HEAT with the HEAT/COOL MODE switch
Select the PROGRAM (A or B) you want to set Ritetemp-8085C-Programmable-Thermostat-FIG.10

  • Touch the PROGRAM icon to select A or B.
    NOTE: Program A has 4 time slots, B can have 2 or 6 time slots.

Select the day you want to programRitetemp-8085C-Programmable-Thermostat-FIG.11
Touch the Day of the week area to cycle through the days of the week to select the desired day.

Select the time slot you want to program Ritetemp-8085C-Programmable-Thermostat-FIG.12

  • Touch the Time slot area to cycle through the available time slots, until it displays the desired time slot.

Select the time of day (must be done in HEAT mode)Ritetemp-8085C-Programmable-Thermostat-FIG.13

  • Touch the Time of Day arrows to move the time selection forward or backward until it displays the desired time. COOL times will be the same as these HEAT times.
  • Select the desired temperature Ritetemp-8085C-Programmable-Thermostat-FIG.14
  • Touch the UP temp / Down temp arrows.
    Repeat the above procedures for each day of the week and each time slot of the day as desired.
    To REVIEW your program touch REVIEW. Each time slot for each day or set of identical days, will be displayed every 3 seconds.
    Return HOME by touching the home icon.

To COPY the program from the current day to another day Ritetemp-8085C-Programmable-Thermostat-FIG.15

  • Touch COPY on the program screen. The current day will remain solid, the destination day will flash.
  • Touch the day area to advance the day and select a copy destination.
  • Touch COPY again to copy all settings to the destination day.

To program for cooling –Ritetemp-8082C-Programmable-Thermostat-FIG.16
Select COOL with the Heat/Cool MODE switch and repeat the above procedure.
NOTE: Due to the requirements of AUTO mode, Time of Day will not be available in COOL programming, and all temperatures must be 3oF or more above the HEAT temp for that time slot. This avoids HEAT – COOL control conflicts over time or target temperature.

Manual

The 8030 has 3 manual override commands. These are accessed by touching the Current Temp Display at the HOME screen (center of the screen).Ritetemp-8085C-Programmable-Thermostat-FIG.17

MANUAL override screen

  • At the Manual override screen, Touch the Temp Up /Temp Down arrows to select your desired temporary Target Temperature. Ritetemp-8085C-Programmable-Thermostat-FIG.14
  •  Touch HOME to return to operation.
  • The OVERRIDE icon will go on indicating you have modified
  • Target Temp for the current Time Slot only (see PG9-Time Slot

HOLD Ritetemp-8085C-Programmable-Thermostat-FIG.18

  •  At the Manual override screen, Touch HOLD to initiate a hold temperature.
  • Touch the Temp Up /Temp Down arrows to select your hold temperature.
  • Touch HOME to return to operation.
  • The HOLD icon will flash indicating you have changed the Target Temp.
  • The system will HOLD this temperature until you return to this screen and de-select HOLD, by touching the HOLD icon again

AWAY – Energy Efficient Pre-set – 

Ritetemp- 8085C-programmable- Thermostat -18

  •  At the Manual override screen, touch AWAY to initiate the away temperature.
  •  HEAT 45F or COOL 90F will be displayed, you can modify this temperature.
  • Your system is in AWAY mode. Touch HOME to return to operation.
  • The AWAY icon will flash indicating you have changed the Target Temp.
  • The system will maintain the AWAY temperature until you return to this screen and de-select AWAY, by touching the AWAY icon again.

Special Features

Swing

  • Swing setting determines the temperature difference from ON to OFF that the thermostat will command the HVAC system to run.Ritetemp-8085C-Programmable-Thermostat-FIG.19
  • With the MODE switch in HEAT or COOL, press the MENU button.Ritetemp-8085C-Programmable-Thermostat-FIG.20
  •  Touch the SWING icon and the current setting of temp swing is shown on the display (default at 3 ).
  •  To change the swing, touch the left or right arrows.
  • The furnace will cycle more at the lower numbers as it tries to keep your set point constant

Low BatteryRitetemp-8085C-Programmable-Thermostat-FIG.21

  • When the batteries are low, the battery icon will come on and flash.
  • The two AA Batteries in the unit need to be replaced. In some installations, your heater system will stop functioning when the thermostat loses power.
  • Replace batteries as soon as you see this warning. The thermostat programs will remain for 60 seconds while the batteries are changed.
  • Do not take longer than 60 sec to change the batteries in your unit or you will lose all custom settings and all programming. Only the EnergyStar ™ program will remain. Once the batteries are replaced, the system will return to normal in 2 seconds.

Filter

  • Press MENU (from HOME screen) and touch FILTER icon.Ritetemp-8085C-programmable- Thermostat -27
  • This will display your accumulated filter run time.
  • To input a new filter life time, touch the FILTER icon for 3 seconds.
  • Input the lifetime hours for your new filter.
  • To zero the filter timer for a new filter, touch the accumulated time display
  • To leave the filter display, touch HOME

Lock

  • Allows you to to prevent any changes in custom settings.Ritetemp- 8085C-programmable- Thermostat -28
  •  To lock, touch the LOCK icon on the MENU screen for 5 sec.
  •  To unlock, Touch the locked icon for 5 sec

12/24 hour

The thermostat can display time in 12 or 24-hour formats. At the HOME screen touch the time display to toggle from 12 to 24-hour display.
E.L. Backlight Backlight comes on automatically when the touch screen is touched or press the Backlight button for 16 sec of illumination.
DST Setting At the MENU screen, the DST toggles the clock on and off.

HUMIDITY

On the HOME screen, the humidity in the room is displayed. This thermostat can control the humidity level  with the proper equipment installed in the HVAC system.
Maximum Humidity setting (Requires air conditioning and COOL mode)-This thermostat can be used to de-humidify by turning on the air conditioning as a function of humidity. Cooler air cannot hold as much moisture.
To set the MAX humidity level desired –Ritetemp-8085C-Programmable-Thermostat-FIG.28

  • From the MENU screen and touch MAX.
  • Use the up/down arrows to set the maximum humidity level you desire.

NOTE: The air conditioner will then be controlled by both humidity and/or temperature. Either one coming on will reduce the temperature and humidity.
Minimum Humidity setting (requires a built-in humidifier and HEAT mode)-This thermostat can be used to humidify by turning on a humidifier in the furnace. Connect the H terminal on the 8082C to the humidifier control relay. To set the MIN humidity level desired –Ritetemp-8085C-Programmable-Thermostat-FIG.29

  • From the MENU screen and touch MIN.
  • Use the up/down arrows to set the MIN humidity level you desire.
    NOTE: When the humidifier is turned on, the fan will also come on automatically.

REFERENCE:

Download MANUALS:

Ritetemp 8085C programmable Thermostat Operational Manual

OTHER MANUALS:

Ritetemp 8085C programmable Thermostat Installational Guide

Ritetemp-LOGO

Ritetemp 8085C programmable Thermostat Operational Manual


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *