Using a TOUCH SCREEN

Please take a moment to try out your touch screen itself.
To test a simple function on the touch screen, place your finger on the time display and give a short firm push. Try a “tap” of the finger or stylus. Your input must last long enough for the system to determine it is not an accidental ‘bump’.
Using the stylus is more comfortable for some users. Again allow the system enough time to recognize your inputs.
When you are comfortable with touch inputs, proceed.
Statement of use: The 6080 can be used with millivolt, 24VAC, single and 2 stage conventional systems, gas/oil/electric heat, 1 stage heat pumps, 2 stage heat pumps, zoned hot water (2 or 3 wire), zoned forced air, single and 2 stage cooling and hybrid systems.Ritetemp-6080-Programmable-thermostat-fig-1

Basic Screens

The MODE SWITCH of the 6080 must be in the HEAT or the COOL position to access all control functions. The 6080 Thermostat has 4 basic screens – HOME, MENU, PROGRAM and MANUAL. The HOME screen is displayed when unit is operating your system. Touching theRitetemp-6080-Programmable-thermostat-fig-2will always return you to this screen. Ritetemp-6080-Programmable-thermostat-fig-3

HOME screen

MENU screen
Displayed when the MENU button is pressed.

Ritetemp-6080-Programmable-thermostat-fig-4

PROGRAM screen
Displayed when the PROGRAM button is pressed.Ritetemp-6080-Programmable-thermostat-fig-5

Configure

Note: The Mode Switch must be in HEAT or COOL mode to configure.

Press MENU to configure the thermostat (from HOME screen). Set day of the week –
Touch the Day of the week area to cycle through the days of the week to select the current day.Ritetemp-6080-Programmable-thermostat-fig-6

Set time of day 
Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for faster setting.

Set oC -oF display
Touch the oF and it will toggle to oC.Ritetemp-6080-Programmable-thermostat-fig-7

Set audible chirp 
Touch the the musical note icon to select the chirp or no chirp.
Return HOME by pressing the home button.

Auto-run

This Thermostat comes preprogrammed with an Energy-StarTM-approved program. This program is recommended by the EPA for energy efficiency.
We strongly recommend that you Auto-Run this program for one week, and see if it works for you. If it does not fit your needs you can always input a custom program.

  • To Auto-Run the Energy-StarTM program, select HEAT or COOL with the mode switch. The unit is now running the Energy-StarTM program.
  • The clock is displayed on the left. The ambient temperature is displayed in the center of the LCD touchscreen. The TIME SLOT icon indicates the TIME SLOT active in the Energy-StarTm program.
  • The programmed temperature is shown on the lower right. For program details refer to the Energy-StarTM program chart below.
EPA MORN DAY EVEN NITE MORN DAY EVEN NITE
HEAT 6:00am 8:00am 6:00pm 10:00pm COOL 6:00am 8:00am 6:00pm 10:00pm
All Days 70oF 62oF 70oF 62oF All Days 78oF 85oF 78oF 82oF

Program

NOTE: 60 Second Rule-During programming, if a button is not pushed in 60 seconds, the unit will return to the home screen. Everything you have changed while programming will be saved.
Select Program you want set – B, C, D, or EPA Prog B has 2 periods, C 4 periods, D 6 periods.
Select HEAT with the HEAT/Cool MODE switch. Press PROG to go to the programming screen.

Select the day you want to program-
Touch the Day of the week area to cycle through the days of the week to select the desired day.

Select the time slot you want to program –
Touch the Time slot area to cycle through the 4 time slots, until it displays the desired time slot.

Select the time of day –
Touch the Time of Day arrows to move the time selection forward or backward until it displays the desired time. Touch and hold for faster time set.Ritetemp-6080-Programmable-thermostat-fig-8

Select the desired temperature 

  • Press the + temp / – temp buttons.
  • Repeat the above procedures for each day of the week and each time slot of the day as desired.
  • To REVIEW your program touch REVIEW. Each time slot for each day or set of identical days, will be displayed every 3 seconds.
  • Return HOME by pressing the home button.

To COPY the program from the current day to another day 

  • Touch COPY on the program screen. The current day will remain solid, the destination day will flash.
  • Touch the day area to advance the day and select a copy destination.
  • Touch COPY again to copy all settings to the destination day.

To program for cooling 
Select COOL with the Heat/Cool MODE switch and repeat the above procedure.Ritetemp-6080-Programmable-thermostat-fig-9

Manual

The 6080 has 2 manual override commands. These are accessed by pressing the + Temp / – Temp buttons.Ritetemp-6080-Programmable-thermostat-fig-10

MANUAL override screen

Note: The Mode Switch must be in HEAT or COOL mode to override.

Temporary OVERRIDE 

  • Press the + Temp / – Temp buttons to select your desired temporary Target Temperature.
  • Press HOME to return to operation.
  • The TEMPORARY icon will go on indicating you have modified the Target Temp for the current Time Slot only (see PG7-Time Slot).

HOLD 

  • At the Manual override screen, Touch HOLD to initiate a hold temperature.
  • Press the + Temp / – Temp buttons to select your hold temperature.
  • Press HOME to return to operation.
  • The ON HOLD icon will flash indicating you have changed the Target Temp. The system will HOLD this temperature until you return to this screen and de-select HOLD, by touching the HOLD icon again.Ritetemp-6080-Programmable-thermostat-fig-11

Special Features

Comfort Level 
There are three COMFORT level selections ECON, NORM , and LX. We recommend the NORM for most areas, LX for severely cold areas (particularly with heat
pumps) and ECON for warm climates (uses less energy). To change the setting, with the MODE switch in heat or cool, press the MENU button. The touch COMFORT level you want unitl it is selected. Ritetemp-6080-Programmable-thermostat-fig-12

Low Battery
When the batteries are low, the battery icon will flash. The two AA Batteries in the unit need to be replaced. In some installations your heater system will stop functioning when the thermostat loses power. Replace batteries as soon as you see this warning. The thermostat programs will remain for 60 seconds while the batteries are changed.
Do not take longer than 30 sec to change the batteries in your unit or you will lose all custom settings and all programming. Only the Energy-StarTM program will remain. Once the batteries are replaced, the system will return to normal in 2 seconds.Ritetemp-6080-Programmable-thermostat-fig-13

Lock Allows you to to prevent any changes in custom settings.
To Lock Level1, touch the LOCK icon on the MENU screen for 2 sec. Level1 allows temporary target adjustments but no program changes To Lock Level2, touch LOCK icon for 2 sec.Ritetemp-6080-Programmable-thermostat-fig-14 Level2 allows no changes. To unlock, Touch the locked icon for 2 secRitetemp-6080-Programmable-thermostat-fig-15.

12/24 hour
The thermostat can display time in 12 or 24 hour formats. At the HOME screen touch the time to toggle from 12 to 24 hr display.

Filter
The 6080 has a feature that keeps track of actual furnace run time and reminds you to periodically replace your systems air FILTER.
Press MENU and touch the FILTER icon.This will display your filter run-time to date in weeks. To zero the FILTER timer for a new FILTER, touch the run-time time display. To input a new FILTER life time, touch the FILTER icon for 3 seconds. Input the life time in weeks for your new FILTER to activate a reminder (FILTER icon on home screen).
To leave the FILTER display, touch the HOME button.Ritetemp-6080-Programmable-thermostat-fig-16

Heat Pump Features
If you have a heat pump with Auxiliary heat, the new sequential staging will give you faster recovery from set backs. The thermostat can be configured for Electric aux or gas/oil aux heat (see installation). If the heat pump cannot maintain your desired room temperature, the new system allows the Aux heat to help maintain your heat all the way to your desired room temperature.
When using a heat pump with Auxiliary heat, if the heat pump is not working, you can shut off the heat pump and use just your auxiliary heat; assuming the 6080 is set up for a heat pump (see installation jumper set up for heat pump). While at HOME screen, push the MENU button. The ON HEAT PUMP icon will be shown (bottom of screen). Touch the HEAT PUMP ICON and it will change to HEAT PUMP OFF. Then push HOME. Auxiliary heat is more expensive than the heat pump, so turn the heat pump back on as soon as possible.

UV BULB
The 6080 allows you to keep track of the actual real time of your Ultra Violet air purifier and can remind you to periodically replace your UV-BULB.
Press MENU and touch UV-BULB icon.
This will display your accumulated bulb running time in weeks. To zero the UV-BULB timer for a new bulb, touch the accumulated time display. To input a new UV-BULB life time, touch the UV-BULB icon for 3 seconds. Input the life time in weeks for your new UV-BULB to activate a reminder (UV-BULB icon on home screen)
To leave the UV-BULB display, touch the HOME button.

H-PAD 
The 6080 allows you to keep track of the actual humidifeir run time of your humidifier pad and can remind you to periodically replace your H-PAD.
Press MENU and touch H-PAD icon. This will display your accumulated humidifier running time in weeks. To zero the H-PAD timer for a new bulb, touch the accumulated time display. To input a new H-PAD life time, touch the H-PAD icon for 3 seconds. Input the life time in weeks for your new H-PAD to activate a reminder (H-PAD icon on home screen). To leave the H-PAD display, touch the HOME button.

RANDOM FAN 
The RANDOM FAN function allows your fan to circulate air for at least 5 minutes per hour for better indoor air quality.
To turn it on or off, touch the MENU button, and touch the RANDOM FAN icon: the ON icon will come be displayed, touch again to turn it off. When the thermostat is controlling the fan, the fan icon will indicate it is running.

TRUE AUTO MODE
The 6080 can automatically switch from HEAT to COOL. In addition to COOL and HEAT modes, the 6080 TRUE AUTO mode switches automatically between heat and cool. Auto switching is normally limited in two ways. The COOL target cannot be any closer than 2F or 3F above the heat target, and the COOL programmed times must be the same as the HEAT programmed times. Unlike all other manufactures, the 6080 TRUE AUTO has no such temperature or time limitations (Patent pending).

REMOTE CONTROL

Note: The remote control cannot work unless the C wire is connected from your HVAC (see installation guide)
The 6080 comes with a 3 channel remote control with a range of as much as 50 feet (walls may reduce this range). If there is interference with the remote, or you are using more than one 6080, you can select a different channel on the remote. The thermostat’s receive channel must then be changed to match that channel by pushing the MENU button and then touching the channel icon at the top right side of the screen. Each time you touch it, it toggles to the next channel.
To use the remote, press up or down, there will be a delay, and then the thermostats target temperature will temporally change one degree per push of the remote. If you wish to restore the target to its program setting, press the RESET button on the remote. If you do not use the RESET button, your change will stay until the next programmed period and go back to the programmed target.
To activate the remote pull out the plastic tab on the back to connect its battery (Battery Type A23 (MN21) 12V).Ritetemp-6080-Programmable-thermostat-fig-17Ritetemp-6080-Programmable-thermostat-fig-18

Remote Control frequency 312MHZ
This device complies with Part 15 of the FCC Rules. Operation is subject to the follow two conditions: (1) This device may not casue harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user`s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, this is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televsion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

HUMIDISTAT

The 6080 has a built in humidistat to control an external humidifier for humidifying. To set a minimum humidity level (with a humidifier installed) from the HOME screen, touch the MENU button then touch the HUMIDITY icon. Touch MIN and use the +/- buttons to set the desired minimum humidity level. The 6080 can be set up to run the humidifier whenever the humidistat calls for humidity (fan also runs) or can be set to run only when the humidistat is calling for humidity and the heat is also running. (Refer installation instruction humidistat).

De-humidifying
The 6080’s built in humidistat can also control the Air Conditioner for de-humidifying. To set a maximum humidity level (using the air conditioner) from the HOME screen, touch the MENU button then touch the HUMIDITY icon. Touch MAX and use the +/- buttons to set the desired maximum humidity level. The 6080 can be set up to run the air conditioner whenever the humidistat calls to de-humidify or can be set to run the air conditioner only when the humidistat calls to de-humidify and the thermostat is also calling for COOL. (Refer installation instruction Humidistat).

6080 Features

This thermostat can be used with all millivolt and 24VAC heating and cooling systems. It cannot be used with line voltage systems. This thermostat is digital and your desired heat or cool temperatures can be easily be set on the large touch screen with the UP/DOWN arrows. A minimum 4 minute off time protects heating and cooling systems from damage. When using a heat pump with Auxiliary heat, if the heat pump is not working, you can shut off the heat pump and use just your auxiliary heat; assuming the 6080 is set up for a heat pump (see installation jumper set up for heat pump). While at HOME screen, push the MENU button. The ON HEAT PUMP icon will be shown (bottom of screen). Touch the HEAT PUMP ICON and it will change to HEAT PUMP OFF. Then push HOME. Auxiliary heat is more expensive than the heat pump, so turn the heat pump back on as soon as possible. Ritetemp-6080-Programmable-thermostat-fig-21

Calibration

NOTE: Your thermostat comes from the factory calibrated to + or – 1oF actual temperature. It is an accurate instrument. If you want your thermostat to display the same temperature as another thermometer in your home, you can adjust it. Maximum calibration is +/-6o .

To change the calibration:

  • Press the MENU button nad touch CALIBRATE.
  • Press the Temp+/- buttons to adjust the temperature reading. CALIBRATE ON will appear on the MENU screen.
  • Press HOME to save the new setting.Ritetemp-6080-Programmable-thermostat-fig-20

Customer Support: 877-505-2353 or
Visit our website www.ritetemp-thermostats.com

REFERENCE:

DOWNLOAD MANUALS:

Ritetemp 6080 Programable thermostat Operational Manual

OTHER MANUALS:

Ritetemp 6080 Programable thermostat Installational Guide

Ritetemp-LOGO

Ritetemp 6080 Programable thermostat Operational Manual


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *