Pro1 Technologies Z955W Wireless Non-Programmable Thermostat
Pro1 Technologies, Inc.
PO Box 3377
Springfield, MO 65804
Toll-Free: 888-776-1427 Web: www.pro1iaq.com Hours of Operation: M-F 9 AM – 6 PM Eastern
This manual covers: Z955W Master Zoning Thermostat
This Z955W Master Thermostat communicates with all components of our wireless zoning system.
Caution
Equipment damage hazard Do not operate the cooling system if the outdoor temperature is below 50 ˚ F (10˚ C) to prevent possible compressor damage.
THERMOSTAT QUICK REFERENCE
Getting to know your thermostat
- LCD (right)
- Glow in the Dark Light Button
- Fan Button
- System Button
- Temperature
- setpoint Buttons
- Menu Button
NOTE ABOUT THE LIGHT BUTTON: This button is used to light up the display, but it is also used to set up communication with the base module. DO NOT hold the light button down for more than 10 seconds, unless you are performing the initial communication setup steps.
Important:
The low battery indicator is displayed when the AA battery power is low. If the user fails to replace the battery within 21 days, the thermostat display will only show the low battery indicator as a final warning before the thermostat becomes inoperable. The batteries are located on the back of the thermostat.
Battery information
On the back of the thermostat insert 2 AA Alkaline batteries (included). Pull the thermostat directly away from the wall to access the batteries. A firm tug will be required to remove the thermostat from the subbase mounted on the wall.
Battery Tip The Master Thermostat must be hardwired (R and C terminals connected to 24 VAC). Batteries may be used for clock backup during power outages, batteries are also recommended to simplify establishing communication process. This allows the installer to take the master thermostat to each zone they are connecting.
THERMOSTAT OPERATION
THERMOSTAT OPERATION
- LCD Display:
See page 2 for details about this display
readout and icons. - Glow in the Dark Light Button:
Press and release the light button to turn on the display light. The glow-in-the-dark light button will self-illuminate for several hours after exposure to ambient light. DO NOT hold down the light button for more than 10 seconds. This will break the communication link between the Z955W and the base module. - Fan Key:
Select ON or AUTO. The ON key will run the fan continuously. The AUTO key will cycle the fan on only when the heating or cooling system is on. - A Note About Programmable Fan:
The programmable fan feature will run the fan continuously during any time period it is programmed to be on. This is the best way to keep the air circulated and to eliminate hot and cold spots in your building. The programmable fan is available for Zone 1, the Local (Master) zone. - System Key:
Selects the operation mode of your HVAC system. Selecting HEAT turns on the heat mode. Selecting COOL turns on the air conditioning mode. Selecting OFF turns both heating and cooling off.
Temperature Setpoint Buttons:
Press the + or – buttons to select the desired room temperature. - Menu Keys:
Use these keys to set up your programming options. Refer to the next page for instructions. - Next Zone:
By selecting NEXT ZONE you can cycle through each of the zones set up during the initial installation.
Caution
When the battery icon appears replace your AA batteries immediately. Failure to do so may result in your heating and cooling system becoming inoperable.
A Note About Zone Control
The Master Thermostat operates as Zone 1 of the Zoning System. Additional zones are controlled by Zone Thermostats. Use the Next Zone key to view the status of additional zones. The Zone Name, Ambient Temperature, System Mode & Setpoint are displayed. Control of additional zones can be given to the zone thermostat or the Z955W Master Thermostat.
Important
You will see a TECHNICIAN SETUP option after the MENU key is pressed.
This TECHNICIAN SETUP key is for installer configuration and should NOT be changed unless you consult your Professional Heating and Air Conditioning Technician.
Keypad Lockout Note
If appears in the display then the keypad is locked. All or some of the keys will not work. Hold the
keys
for 3 seconds to remove the lock.
A Note About Programmable Fan
The programmable fan feature will run the fan continuously during any time period it is programmed to be on. This is the best way to keep the air circulated and to eliminate hot & cold spots in your building. The programmable fan is available for Zone 1, the Local (Master) zone.
Set Time
Follow the steps below to set the current time:
- Press MENU
- Press SET TIME
- The day of the week will be ashing.
- Use the
or
key to select the current day of the week.
- Press NEXT STEP The current hour is ashing. Use the
or
key to select the current hour. When using 12-hour time, make sure the correct a.m. or p.m. choice is selected.
- Press NEXT STEP Minutes are now ashing. Use the
or
key to select current minutes.
- Press DONE when completed
PROGRAMMING THE THERMOSTAT
Set 5+1+1 Program Schedule
To customize your 5+1+1 program schedule, follow these steps
Weekdays:
- Select HEAT or COOL using the SYSTEM key.
Note: You have to program heat and cool each separately. - Press MENU
- Press SET SCHED. Note: Monday-Friday is displayed and the WAKE icon is shown. You are now programming the WAKE time period for the weekday setting. Additional Step for Independent Zone Programming The NEXT ZONE key can be pressed to select each zone to be programmed. The system information will display the name of the zone that is being programmed. Each zone can be programmed independently.
- The first zone to be programmed will be named LOCAL. Use the
or
key to make your time selection for the weekday WAKE time period. Note: If you want the fan to run continuously during this time period, select ON with the FAN key. This can only be done for your LOCAL ZONE 1.
- Use the
or
key to make your setpoint selection for the weekday WAKE period.
- Press NEXT ZONE. Repeat steps 4 and 5 for each remaining zone. Press NEXT ZONE to toggle zones. NOTE: Zones can have names such as LIVING ROOM, BEDROOM, etc.
- Press NEXT STEP
- Repeat steps 4 through 7 for the weekday LEAVE time period, for the weekday RETURN time period, and for the weekday SLEEP time period.
- Repeat steps 4 through 7 for the Saturday WAKE time period, for Saturday, LEAVE time period, for the Saturday RETURN time period, and for the Saturday SLEEP time period.
- Repeat steps 4 through 7 for the Sunday WAKE time period, for Sunday, LEAVE time period, for the Sunday RETURN time period, and for the Sunday SLEEP time period.
Set 7-Day Program Schedule
To customize your 7-day program schedule, follow these steps:
Monday
- Select HEAT or COOL using the SYSTEM key.
Note: You have to program heat and cool each separately. - Press MENU
- Press SET SCHED. Note: Monday-Friday is displayed and the WAKE icon is shown. You are now programming the WAKE time period for the weekday setting. Additional Step for Independent Zone Programming The NEXT ZONE key can be pressed to select each zone to be programmed. The system information will display the name of the zone that is being programmed. Each zone can be programmed independently.
- The first zone to be programmed will be named LOCAL. Use the
or
key to make your time selection for the weekday WAKE time period. Note: If you want the fan to run continuously during this time period, select ON with the FAN key. This can only be done for your LOCAL ZONE 1.
- Use the
or
key to make your setpoint selection for the weekday WAKE period
- Press NEXT ZONE. Repeat steps 4 and 5 for each remaining zone. Press NEXT ZONE to toggle zones.
NOTE: Zones can have names such as LIVING ROOM, BEDROOM, etc. - Press NEXT STEP
- Repeat steps 4 through 7 for the weekday LEAVE time period, for the weekday RETURN time period, and for the weekday SLEEP time period.
Tuesday, Wednesday, Thursday, Friday, Saturday, and Sunday Repeat steps 4 thru 7 for the remaining days of the week.
A Note About Zone Control
The Master Thermostat operates as Zone 1 of the Zoning System. Additional zones are controlled by the zone thermostats. Use the Next Zone key to view the status of additional zones. The Zone Name, Ambient Temperature System Mode & Setpoint are displayed. Control of additional zones can be given to the zone thermostat or the Z955W Master Thermostat.
A Note About Programmable Fan
The programmable fan feature will run the fan continuously during any time period it is programmed to be on. This is the best way to keep the air circulated and to eliminate hot and cold spots in your building. The programmable fan is available for Zone 1, the Local (Master) Zone.
Next Zone
The NEXT ZONE key cycles through all zone thermostats connected to your wireless zoning system. LOCAL shows the ambient temperature of the Master Thermostat only. The name of each zone thermostat will show and the ambient temperature for that zone only will be displayed. For more information, see the Zone Thermostat User Guide.
Filter Change Reminder
If your installing contractor has configured the thermostat to remind you when the air filter needs to be changed, you will see FILT in the display when your air filter needs to be changed. FILT will be shown in the display after your system has run long enough to require an air filter change. Resetting the filter change reminder: When the FILT reminder is displayed, you should change your air filter and reset the reminder by pressing the CLEAN key for 3 seconds. FILT will leave the display when reset.
Temporary and Permanent Hold Feature
Temporary hold: The thermostat will display HOLD and RUN SCHEDULE on the bottom of your screen when you press the or
key. If you do nothing, the temperature will remain at this setpoint for four hours. Your program setpoint will then replace your temporary setpoint. Permanent hold: If you press the HOLD key at the bottom of your screen, you will see HOLD appear next to the setpoint temperature in the display. The thermostat will now permanently stay at this setpoint and can be adjusted using the
or
keys. To return to the program: Press the RUN SCHEDULE key at the bottom of your screen to exit either temporary or permanent hold.
WARRANTY INFORMATION
Warranty Registration
Your new thermostat has a 5-year limited warranty. You must register your warranty within 60 days of installation. You can register your new thermostat in 2 ways.
- Go to our company website, select warranty registration, and fill out a short registration form.
– or – - Complete the form below and mail it to the address shown.
Warranty Registration
Name: ____________________________
Address: ____________________________
____________________________
City: ____________________________
State: ____________________________
Zip: _____________________
Thermostat Model: _____________________
Date Installed: _____________________
Complete the form and mail it to Thermostat Warranty Registration PO Box 3377
Reference
Download Manual:
Pro1 Technologies Z955W Wireless Non-Programmable Thermostat Operational Manual
OTHER MANUALS
Pro1 Technologies Z955W Wireless Non-Programmable Thermostat Installational Manual
Pro1 Technologies Z955W Wireless Non-Programmable Thermostat Product Specifications Guide
Pro1 Technologies Z955W Wireless Non-Programmable Thermostat Operational Manua
Leave a Reply