Poly Pool LOGO

Poly Pool PP1465 “EASY” DIGITAL CHRONO THERMOSTAT 

Poly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-  PRO -

GENERAL WARNINGS

This type of relay ambient thermostat is suitable for regulating many models of available boilers. It can be easily connected to any boiler or air conditioner that has a two-wire connector, regardless of the 24V or 230V supply. The device can be programmed to suit your needs so that the heating/cooling system heats/cools your residence or office to the desired temperature, on the days and at the times specified by you, to reduce energy costs while maintaining comfort. The chronothermostat has 6 separate and independent daily temperature programs (intervals) that can be set for each day of the week. Ignition times can be set at 10 minute intervals and temperatures can be adjusted in 0.5°C increments.

Poly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-1

Thermostat buttons Poly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-  PRO - 2

The thermostat ignition sensitivity can be selected:

Information shown on the LCD display of the thermostat:Poly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-  PRO - 3

POSITION OF THE THERMOSTAT
Position the thermostat in a position protected from temperature changes or extreme heat (e.g., direct sunlight, refrigerator, fireplace, etc.). The optimum installation position is approximately 1.5 m above floor level.

IMPORTANT WARNING!
If the radiator valves in your apartment are equipped with a thermostatic head, replace the thermostatic radiator valve head with a manual control handle or adjust it to the maximum temperature in the room where the thermostat is to be positioned, otherwise the thermostatic head can interfere with the temperature control of the apartment.

THERMOSTAT INSTALLATION

ATTENTION! The device must be installed by a qualified installer. Always follow the manufacturer’s instructions when connecting the thermostat to any heating or cooling device.

BASIC SETTING

Inserting the batteries

Set current date and time

Set ignition sensitivity

Activation of the pump protection function
With the factory settings, the pump protection function is inactive. It can be activated or deactivated by pressing the “DAY”, “PROG” buttons one after the other and the (-) or (+) buttons; return to the main screen by pressing the “SET” button. The “HP: OFF” (off) or “HP: ON” (on) setting is confirmed by pressing the “SET” button. (After approximately 10 seconds the settings are automatically confirmed and the device returns to the main screen). By pressing the “RESET” button, the pump protection function is reset to the factory settings

(“HP:OFF”). To prevent the pump from blocking, the pump protection function turns on the boiler for one minute at 24 every day outside the heating season.
The pump protection works if the boiler is also on during the summer. It is reasonable to set a low temperature level on the thermostat during this period, for example +10°C, to prevent unnecessary starts to the boiler when the weather becomes temporarily cold).

PROGRAMMING THERMOSTAT

Thermostat programming allows setting of the switch-on hours and selection of the desired temperatures for each programming band. The thermostat can be programmed in daily/weekly mode and can manage 6 daily schedules and two temperature levels. The temperature set for a specific time interval is valid until the next time interval is activated. For example, the thermostat keeps the programmed temperature for the switch-on time P1 until the switch-on time P2 is activated. Note! The thermostat software recognises only increasing consecutive progressions to be set, based on the series number (P1; P2; etc.) of the ignitions. For example, P3 cannot have a lower time than the one associated with P2 With the factory settings the thermostat operates with the following programming for all the days of the week:

Poly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-  PRO - 6

Program settings:

To set a different program for each day, the programming must be performed separately for each day of the week, selecting the days one by one. (If there are days for which it is intended to create the same program, simply create the program only once, because it can be easily applied to every other day via the “COPY” button as described in section 4.2).
If not all six daily ranges are required, it is possible to omit the adjustment of certain programs by pressing the “DAY” button during programming on the unwanted program. The display shows this process through lines (- – – -), which appear on the time and temperature segments. The ignition omitted can be restored or activated at any time by repeating the programming steps (points 1 to 7) and pressing “DAY” on the previously reset program

“COPY” function

Inspection of the program

Program cancellation

FACTORY VALUES COMBINED WITH THE BUTTONS (-) AND (+)

Changing the temperature until the next ignition program

Temperature change for 1-9 hours (party program)
Set the desired temperature by pressing the (-) or (+) buttons and then press the “DAY” button. The symbolPoly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-  PRO - 9 appears on the display together with the number 1, which indicates the duration of the change (in hours). Press theDAYbutton to set the desired forcing hours (from 1 to 9 hours). The thermostat will maintain the modified temperature for the period of time set. After this time has elapsed, the symbolPoly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-  PRO - 9 disappears and the thermostat returns to the program that was set. The “Party” function can be interrupted by returning to the set program by pressing the “SET” button.

Temperature change for 1-99 days (holiday program)

Changing the temper-ature until the next manual interference

TURN ON THE BACK- GROUND LIGHT
Press the “LIGHT” button to activate the display background light which will light up for 10 seconds. If other buttons are pressed while the backlight is on, it will go off 10 seconds after the last button has been pressed.

CHANGING THE BATTERY

The average battery life is 1 year, but frequent use of the background light can considerably reduce this time. If the symbolPoly Pool -PP1465- “EASY” DIGITAL- CHRONO- THERMOSTAT-  PRO - 10 on the display shows a low battery charge, replace the batteries (see Section 2). After replacing the batteries, proceed to set the day, hour and minutes again, while the set programs remain stored and it is therefore not necessary to reprogram the thermostat. The “RESET” button cancels all the programs and returns the thermostat to the factory settings.

TECHNICAL SPECIFICATIONS

WEEE

Appliance is compliant with the Electromagnetic Compatibility Directives, RoHS, and Low Voltage subject to technical modifications.

Information to users: pursuant to art. 26 of Italian Legislative Decree 14 March 2014, no. 49 “Implementation of Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)” The symbol of the crossed-out wheelie bin reported on the equipment or on its packaging indicates that the product at the end of its useful life must be collected separately from other waste. Therefore, the user must deliver the equipment at the end of its life to the appropriate municipal centres for the separate collection of electro-technical and electronic waste. As an alternative to autonomous management, it is possible to deliver the equipment to be disposed of to the retailer, when purchasing a new equivalent type of equipment. It is also possible to deliver electronic products to be disposed of, smaller than 25 cm, free of charge, to retailers of electronic products with a sales area of at least 400 m2. Adequate separate collection for subsequent recycling, treatment and environmentally compatible disposal contributes to avoiding possible negative effects on the environment and on health and encourages reuse and/or recycling of the materials of which it is composed.

Poly Pool S.p.A.

Reference

Download manual:

Poly Pool PP1465 “EASY” DIGITAL CHRONOTHERMOSTAT User Instruction

Poly Pool LOGO

Poly Pool PP1465 “EASY” DIGITAL CHRONO THERMOSTAT User Instruction

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)