Technical Data

SIGNALS AND CONTROLS

Temperature display

The display normally shows the detected room temperature. When setting the temperature with the knob, the display shows the set temperature; a few seconds after the end of the operation the room temperature is shown again. In mode the set temperature shown is the reduced temperature: “Reduction” -4 °C from the Winter/ set temperature (for Summer model: -4 °C on “ ” and +4°C on “ ”). Winter Summer

Blinking signalsPERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT-  1

PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT- 2

Operation mode switch (according to model)

PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT 3

INSTALLATION GUIDELINES

Installation of thermostat: independent – fixed
Wall mounting

PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT 4

FIXING BASE TO THE WALL

SWITCH MAINS SUPPLY OFF
Fix with screws the base of the thermostat to the back box (or to the wall), using the pairs of holes provided.

ELECTRICAL CONNECTIONS

SWITCH MAINS SUPPLY OFF

Connect 230 V power supply wires to the terminals

Connect the controlled device to the terminals:

If you want to use remote selection of “ comfort” / “Reduction ” temperature, connect the exterior contact (potential-free – e.g.: from time switch) to the terminals and of the thermostatPERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT- 6

Remote selection of “Comfort” or “Reduction – ” temperature

Comfort ” temperature = Open contact
Reduction ” temperature = Closed contact
N.B control is operational within one minute.

PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT- 7

Note for the contractor
Make the electrical connections taking particular care in the event of surface mounting without box that the wires are correctly arranged and do not hinder a proper fit between the body and the base.

PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT8

IN MULTIPLE INSTALLATIONS (offices, schools,houses)with a single, centralized “Reduction” control (es.: Time switch).

Thermostats supply voltage (230 V)

Inputs for “Reduction” control –

TEMPERATURE DIFFERENTIAL VALUE SETTING
The thermostat operates in differential modes (ONOFF) with a modifiable differential value (factory-set to 0,5 °C).

Changing the differential: position the dip-switches, located on the back of the thermostat, for the required differential value.PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT 10

FIXING THE THERMOSTAT TO BASE

Fit the body to the base Exert light pressure until you hear the click of the attachment hooks. To remove the device insert a smal screwdriver as a lever in the position corresponding to the attachment hooks PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT 12

LIMITATION OF THE MAXIMUM ROOM TEMPERATURE

PERRY- 1TP-TE400-B -WALL -MOUNTING -ELECTRONIC -DIGITAL -THERMOSTAT 13

REFERENCE:

DOWNLOAD MANUALS:

PERRY 1TP-TE400-B WALL MOUNTING ELECTRONIC DIGITAL THERMOSTAT

Perry-LOGO

PERRY 1TP-TE400-B WALL MOUNTING ELECTRONIC DIGITAL THERMOSTAT  USER MANUALS

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)