peco-logo

PECO T372P Thermostat

PECO-T372P-Thermostat-PRODUCT

Caution
Equipment damage hazard. Do not operate the cooling system if the outdoor temperature is below 50 °F (10 C) to prevent possible Compressor damage.

Thermostat Operation

PECO-T372P-Thermostat-FIG-1

  1. LCD Display
    See page 4 for details about this display readout.
  2. Fan Switch
    Select ON or AUTO. ON will run the fan continuously. AUTO will cycle the fan on only when the heating or cooling system is on.
  3. System Switch
    Selects the operation mode on your HVAC system. Selecting HEAT turns on the heat mode. Selecting COOL turns on the air conditioning mode. Selecting OFF turns both heating and cooling off.
  4. Temperature Setpoint Buttons 
    Press the + or – buttons to select the desired room temperature.
  5. User Buttons
    Use these buttons to set up your programming options. Refer to the next page for detail.

Caution:
When the battery icon PECO-T372P-Thermostat-FIG-2 appears replace your AAA batteries immediately. Failure to do so may result in your heating & cooling system becoming inoperable.freezing or overheating can occur.

PECO-T372P-Thermostat-FIG-3

Important:
The low battery indicator is displayed when the 2x AAA battery power is low.

Battery Door Information

PECO-T372P-Thermostat-FIG-4

Temporary and Permanent Hold Feature (if using programming)

Filter Change Reminder

If your HVAC contractor has configured the thermostat to remind you when the air filter needs to be changed, you will see FILTER in the display when your air filter needs to be changed.
Resetting the filter change reminder: When the FILTER reminder is displayed, you should change your air filter and reset the reminder by holding down the second button from the top left side of the thermostat for 3 seconds.

PECO-T372P-Thermostat-FIG-7

Programming The Thermostat

SetTime

  1. Press the MENU button
  2. Press SET TIME
  3. Day of the week will be flashing. Use thePECO-T372P-Thermostat-FIG-5 toPECO-T372P-Thermostat-FIG-6 select the current day of the week. key
  4. Press NEXT STEP
  5. The current hour is flashing. Use the key to sure the correct PECO-T372P-Thermostat-FIG-5or PECO-T372P-Thermostat-FIG-6 choice is selected.
  6. Press NEXT STEPP Minutes are now flashing. Use the or key key to select Current minutes.
  7. Press DONE when completed.

Set Program Schedule 5+1+1

To customize your program schedule, follow these steps: 

  1. Select HEAT or COOL with the system switch. Note: You have to program heat and cool each seperately.
  2. Press the MENU button (If menu does not appear first press RUN SCHED)
  3. Press SET SCH ED. Note: Monday-Friday or (Monday if in 7 Day) is displayed and the WAKE icon is shown. You are now programming the wake time period for that day.
  4. Time is flashing. Use the PECO-T372P-Thermostat-FIG-5 or PECO-T372P-Thermostat-FIG-6 key to make your time selection for tfiat day’s WAKE time period.
  5. Press NEXT STEP
  6. The setpoint temperature is flashing. Use the PECO-T372P-Thermostat-FIG-5 or PECO-T372P-Thermostat-FIG-6 key to make your setpoint selection for that day’s WAKE time period.
  7. Press NEXT STEP
  8. Repeat steps 4 thru 7 for that day’s LEAVE time period, RETURN time period, and SLEEP time period.

Saturday:
Repeat steps 4 through 7 for the Saturday WAKE time period, LEAVE time period, RETURN time period, and for the Saturday SLEEP time period.

Sunday:
Repeat steps 4 through 7 for the Sunday WAKE time period, LEAVE time period, RETURN time period, and for the Sunday SLEEP time period.

PECO-T372P-Thermostat-FIG-8

Technician Setup Menu

  1. Press MENU button.
  2. Press and hold TECH SET button for 3 seconds.
  3. Configure the installer options as desired using the table below.
    Use the+ OR – keys to change settings and the NEXT STEP or PREV STEP key to move from one option to another.

Note: Only press the DONE key when you want to exit the Technician Setup Options.

PECO-T372P-Thermostat-FIG-9PECO-T372P-Thermostat-FIG-10

FILTER Setting:
Display SE Fl, flashing 1000 (the default value is 1000 hours), and select from 50-2000 hours. Temperature Calibration: Display CAL and flashing O.F (the default value 0), select from -3-3.F. Compressor Shortest Running Time Setting: Display AN ON and flashing

Terminal Designations

REFERENCE:

DOWNLOAD MANUALS:

PECO T372P Thermostat Instruction Manual

OTHER MANUALS:

PECO T372P Thermostat Installational Manual

PECO T372P Thermostat Product Specifications Guide

peco-logo

PECO T372P Thermostat Instruction Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)