Peco T12000 Non Programables Thermostat Operating Manual

peco-logo Peco T12000 Non Programables Thermostat

Peco-T12000-Non-Programables-Thermostat-product

  • Touchscreen technology
  • Large 12 square inch blue display
  • 7 available outputs, including economizer
  • SD memory card interface
  • 365-day, 20-holiday programmability
  • 7-day, 5-1-1, 5-2 programming

THE PECO PERFORMANCE PRO T12000 SERIES

Thank you for choosing a PECO® Performance PRO™ thermostat. The Performance PRO T12000 Series is intended for use in residential and commercial environments. It is designed for and can support up to 3-HEAT/ 2-COOL configurations in conventional systems and heat pump applications. The Performance PRO also provides the capability to meet the requirements for ASHRAE 90.1-2004 and California Building Code Title 24 (2008 edition).

The Performance PRO T12000 Series is comprised of the T12000 non-programmable thermostat models and the T12500 programmable thermostat models. The T12500 model features a 12 square inch blue backlit display with dynamic menus, accessed using touchscreen keys. All Performance PRO T12000 Series offers the following standard features: auto-changeover, optional remote sensors, occupancy sensors, three levels of keypad lockout, a PIN access code, and filter replacement reminder. The T12500 programmable models contain up to four scheduled events per day, a 365-day calendar, 20 holidays, holiday override, temporary override, a Power Harvesting feature (also known as “power stealing”) to preserve battery life, Secure Digital (SD) card capability (card not included), and optional humidity control (T12532 IAQ only). The T12000 Series can be powered by 24 VAC or batteries or both (recommended). The T12000 Series can control up to 7 outputs and monitor three external sensors. The T12000 Series mounts onto any PECO Performance PRO Series wallplate.

CAUTION!

  • READ THE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO OPERATE THIS THERMOSTAT.
  • FOLLOW THE PERFORMANCE PRO INSTALLATION INSTRUCTIONS BEFORE PROCEEDING.
  • Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH, AND/OR PROPERTY DAMAGE.
  • Use this thermostat only as described in this manual.
  • This is a 24 VAC low-voltage thermostat. Do not install on voltages higher than 30 VAC.
  • Contact a qualified service person if at any time the thermostat does not operate properly.
  • Use care to avoid static discharge to the thermostat.
  • To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full thermostat operating voltage.
  • To avoid potential fire and/or explosion, do not use in potentially flammable or explosive atmospheres.
  • This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed nor controlled by PECO.
  • All wiring and applications must conform to local and national building codes and ordinances. Applications and national codes must be reviewed prior to installation to assure the installation is functional and safe.

IMPORTANT NOTE: This thermostat was shipped with factory default settings. The thermostat’s installer may have configured the thermostat differently from the factory-default settings and may have modified
or disabled certain features. Contact the installer or a service technician if there are questions about the thermostat’s configuration.

QUICK REFERENCE: DEFAULT DISPLAY MODE

Default Display
The factory-programmed settings show the time, temperature, and setpoint. This is called the Default Display. The Default Display appears after a short period of inactivity. The Default The display can be custom configured to show user-selected items only (see Service Menu 520 in “Performance PRO T12000 Series Installation Guide”).

Peco-T12000-Non-Programables-Thermostat-fig-1

Note: The Battery Indicator, Service Indicator, Filter Indicator, and Secure Digital (SD) icons appear at bottom of the digital display if user action is required.

QUICK REFERENCE: HOME DISPLAY MODE & NAVIGATION

Home Display
The Performance PRO T12000 Series has a touchscreen digital display, with variable menu keys (shown below). To make a selection from a multiple-option key, press the key continuously. The flashing option is automatically selected. Available submenus depend on system type and menu navigation.

Peco-T12000-Non-Programables-Thermostat-fig-2

Press the blank area of the touchscreen to enter Home Display from Default Display. Navigate submenu options to customize thermostat settings. Available options are:
Edit – Allows the user to edit variable settings (e.g., Cool/Heat Setpoints) within the submenus.
Done – Saves settings and reverts to the Home Display.
Cancel – Discards changes and reverts to the Home Display.

Peco-T12000-Non-Programables-Thermostat-fig-3

TKEEXYT OPERATION PRESS ANY KEY TO BEGIN

Fan key
Used to select among two fan menu options:
ON – Continuous fan operation.
AUTO – The fan is activated only when there is a demand for heat or cooling, with some exceptions.
Note: Several Service Menu options affect the fan operation (See Advanced in the “Performance PRO T12000 Series Installation Guide.”)

System key
Used to control the operating mode of Performance PRO T12000 Series thermostats. Available options are dependent on the system type selected (see Advanced Configuration in “Performance
PRO T12000 Series Installation Guide”). System modes:
HEAT – Select the system to operate in heating mode only. Only one setpoint is displayed.
COOL – Select the system to operate in cooling mode only. Only one setpoint is displayed.
AUTO – Allows the system to control to both the Heat and Cool setpoints. The system will automatically change over between heating and cooling modes as room temperature
varies. The cool Setpoint must always be greater than Heat Setpoint by the dead band value.
OFF – Disables all thermostat outputs; only zone temperature and time are displayed.
EMERGENCY (Em) – Emergency heat can be used when the Heat Pump cannot keep up with the heat load. Use Service Menu 110 (System Type 6 & 11) to enable.

Note: Deadband is the user-defined minimum difference between the Cool Setpoint and Heat Setpoint (see Service Menu 380).

Schedule key
Used to view Schedule Display and program two or four scheduled events per day (with Heat and Cool Setpoints) including Occupied1, Occupied2, Unocc1, or Unocc2.

Holiday key
Used to view Holiday Display and schedule up to 20 different holidays.

Clock key
Used to view the clock format (12 or 24 hours) and to set the clock time.

Cool Setpoint & Heat Setpoint
Used to create a temporary override of the current setpoint temperature. Pressing Cool Setpoint or Heat Setpoint shows Override Display. The user selects desired Heat and Cool Setpoints and “Hold Until” time for Override, using time ▲/▼keys. (Cool Setpoint is greater than Heat Setpoint by the dead band.) Note: Available options depend on the system type selected.

Override key
Used to view Override Display and create a temporary override of scheduled events. Heat Setpoint, Cool Setpoint, and override time may all be adjusted from Override Display

Temporary Override – The active setpoint is taken from setpoints defined in the Override menu. (In Home Display, “Override” fl ashes during the override time period if selected.)

Screen key
Press Screen key:“Clean Screen” fl ashes for 30 seconds, allowing cleaning with no key input.

Service Indicator
Icon appears to notify the user that the remote temperature sensors are reading out of range.

Peco-T12000-Non-Programables-Thermostat-fig-6Battery Indicator
The icon shows the battery’s current charge level in segments. Two AA Alkaline batteries (2.6 – 3.1VDC) have an approximate 1-year life expectancy.
Keypad Lockout
Icon appears if any type of keypad lockout is active. Keypad lockout blocks access to certain
features of the thermostat. (See Service Menu 340 to enable keypad lockout).
Filter Indicator
Icon appears in the Default Display when the reminder timer expires (see service menu 230).
The thermostat will continue to return to the filter menu until the Done key is pressed. After the Filter Indicator icon appears, pressing Done will restart the filter timer.

Secure Digital (SD)
Icon appears (flashes) when SD card is inserted (optional SD card not provided). SD card functionality allows user to upload/download settings to/from a PECO-formatted SD card (see section “Load SD card settings” )

SET THE CLOCK, MONTH, AND DAY

Peco-T12000-Non-Programables-Thermostat-fig-7

Note: At any time, press Cancel to abort the current selection and return to Home Display, or press Done to save changes and return to Home Display

  1. From the Home Display, Press the Clock key.
  2.  Press ▲/ ▼ to select 12 or 24 HR format, then press Clock.
  3.  Press ▲/ ▼to select clock hour, then press Clock.
  4. Press ▲/▼to select clock minutes, then press Clock.
  5. Press ▲/ ▼ to select clock year, then press Clock.
  6. Press ▲/ ▼ to select the current month, then press Clock. Note: Month appears.
  7. Press ▲/ ▼to select the current numerical date. Note: Days appear.
  8. Press Done to finish Clock mode.

SELECT FAHRENHEIT OR CELSIUS TEMPERATURE

Peco-T12000-Non-Programables-Thermostat-fig-8

Note: To custom, configure the thermostat settings and access more Service Menus (See Advanced Configuration in the “Performance PRO T12000 Series Installation Guide”).

  1. Press the lower left and lower right touchscreen areas simultaneously for about five seconds. Note: Service Menu “100” appears with a default value.
  2. Press Cool ▲/ ▼ continuously until Service Menu “260” appears.
  3. In Service Menu 260, Press ▲/ ▼to select the desired temperature display:1” for Fahrenheit (default)“0” for Celsius
  4.  Press Done when you have completed your selection.

Note: After you complete your selection, Home Display shows the temperature in the format selected.

SELECT THE FAN MODE AND PRESS THE TOUCHSCREEN TO BEGIN

Peco-T12000-Non-Programables-Thermostat-fig-10

  1. Press Fan to set fan operation.
  2. Press Fan to select “On,” or “Auto.”
    Note: Selected option fl ashes.
  3. Select Done to save changes.
    Note: “On” mode indicates continuous output. “Auto” mode indicates that the fan is activated only when there is a demand for heat or cooling. Some exceptions apply (see Advanced Configuration in the “Performance PRO T12000 Series Installation Guide”).

SELECT SYSTEM MODE

Peco-T12000-Non-Programables-Thermostat-fig-10

  1. Press Fan to set fan operation.
  2. Press Fan to select “On,” or “Auto.”
    Note: Selected option fl ashes.
  3. Select Done to save changes.
    Note: “On” mode indicates continuous output. “Auto” mode indicates that the fan is activated only when there is a demand for heat or cooling. Some exceptions apply (see Advanced Configuration in the “Performance PRO T12000 Series Installation Guide”).

Note: At any time, press Cancel to abort the current selection, or press Done to save changes and return to Home Display

RESET FILTER TIMER

Peco-T12000-Non-Programables-Thermostat-fig-11

The Filter Indicator serves as a reminder to change the furnace filter (see note below). When the filter timer expires, a Filter Indicator appears.

  1. From the Default Display, press any key to enter the Filter mode (FIL/Filter, Cancel, and Done appear).
  2. Press Done to reset the filter timer.
    Note: Pressing Done restarts filter timer with the previous time value selected.
  3. Press Cancel to bypass the reminder and return to the Home Display. PRESS THE TOUCHSCREEN TO BEGIN
    Note: The thermostat will return to the Filter menu from the Default Display until Done is selected (see Service Menu 230 in the “Performance PRO T12000 Series Installation Guide” for settings).

PROGRAM THE THERMOSTAT (T12500 MODELS ONLY)

Each day has two or four scheduled events (Occupied1, Occupied2, Unocc1, and Unocc2) per day, depending on the Service Menu configuration. Each event can be programmed with a start time and Heat and Cool Setpoints. Heat Setpoint controls system heating during cold weather. Cool Setpoint controls system cooling during hot weather. The T12000 Series is preprogrammed with factory default settings for seven days of the week as follows:

Time Period Start Time Heat Setpoint Temperature Cool Setpoint Temperature
Occupied1 8:00 am 70° F (21° C) 75° F (24.0° C)
Unocc1 10:00 pm 55° F (10° C) 85° F (29.5° C)
Occupied2
Unocc2

Note: To change the preprogrammed times and/or setpoint temperatures, follow the instructions under “Program scheduled events.”
Note: See Service Menu 240 to enable two or four scheduled events per day.

PROGRAM SCHEDULED EVENTS

Peco-T12000-Non-Programables-Thermostat-fig-12

Note: Unless Occupied1 and Unocc1 are programmed, their factory default settings will apply.

  1. Schedule two or four events per day: Occupied1, Occupied2, Unocc1, and Unocc2. Press Schedule to view options.
  2. Press OCC1, UNOCC1, OCC2, or UNOCC2 to schedule an event.
    Note: See Service Menu 100 to select the schedule format. See Service Menu 240 to enable two or four events per day.
  3. Press Edit to create settings for event.
    Note: OK to Pick Multiple Days appears below days.
  4. Press day(s) desired.
    Note: Selected day(s) shows squarePeco-T12000-Non-Programables-Thermostat-fig-13 (Optional: Select/ deselect more days to program multiple days simultaneously.)
  5. Press ▲/ ▼to schedule the start time (in 15-minute increments) for the eventPeco-T12000-Non-Programables-Thermostat-fig-14
  6. Now select a Heat Setpoint and Cool Setpoint for the scheduled event (available options depend upon system type selected).
  7. Press Cool ▲/ ▼to select Cool Setpoint.
  8. Press Heat ▲/ ▼to select Heat Setpoint.
  9. Schedule next event (e.g.,UNOCC1) and repeat steps 2-7.
    Note: Previously selected days remain active for programming unless changed.
  10. Press Done to exit Schedule mode. PROGRAM SCHEDULED EVENTS Note: To program 5-1-1 day or 5-2 days format, see Service Menu 100 (“Performance PRO T12000 Series Installation Guide”).

Note: At any time, press Cancel to abort current selection, or press Done to save changes and return to Home Display

PROGRAM OVERRIDE

Peco-T12000-Non-Programables-Thermostat-fig-15

Note: Available setpoints are determined by the system mode selected (see “Select system mode”).
Note: The installer setup can limit override to 1, 2, 3, or 4 hours beyond the current time

Override allows temporary override of heat or cool settings (example uses System Auto).

  1. Press the Override key.
    Note: “Hold until” time appears and is changed to show the length of override (up to the maximum hold time specified in Service Menu 395).
  2. Press Cool ▲/ ▼to select a Cool Setpoint.
  3. Press Heat ▲/ ▼to select a Heat Setpoint.
  4. Press ▲/ ▼to adjust time (in 15-minute increments) override remains in effect.
  5.  Press Done to save changes and exit.
    Note: Override remains (flashing) in effect until the time period ends.
    Note: Press Cancel to exit Override

SELECT HUMIDITY SETPOINTS

Peco-T12000-Non-Programables-Thermostat-fig-16

Note: Instruction assumes humidity sensor is installed and is enabled (see Service Menu 490). Integrated sensors (not included) must be ordered separately the sensor is present, which allows user to set dehumidify and humidify control setpoints.

  1. Press the lower left and lower right keypad area to activate Service Menus.
  2. Press Cool ▲/ ▼for Service Menu 490.
  3. Select the appropriate option to enable Dehumidify, Humidify, or both (1, 2 , or 3).
  4. Press Done to return to Home Display.
  5. Press the Humidity key to set Dehumidify Setpoint. Beside “dE” Press ▲/ ▼to select desired Dehumidify Setpoint.
  6. Press the Humidity key to view Humidify Setpoint. Next to “hu” Press ▲/ ▼to select desired Humidify Setpoint.
  7. Press Done to save and exit.

PROGRAM A HOLIDAY

Peco-T12000-Non-Programables-Thermostat-fig-17

Note: Performance PRO supports 20 holidays, leap years, and daylight-saving time.

  1. Press Holiday to enter menu.
  2. Press Holiday continuously to select holiday number (1-20).
  3. Press Edit to select the holiday month.
    Note: Month number fl ashes.
  4. Press ▲/ ▼to select (numerical) month, then press Holiday.
  5. Press ▲/ ▼ to select (numerical) day on which holiday starts (Days icon appears), then press Holiday.
  6. Above Days, press ▲/ ▼to set holiday length, which is number of days that the holiday period lasts (1-99). Optional: To schedule additional Holidays, wait for fl ashing Holiday number, and repeat Steps 4-6.
  7. Press Done to save and exit

LOAD SD CARD SETTINGSPeco-T12000-Non-Programables-Thermostat-fig-18

Note: If SD card is locked, only Paste appears; user may only copy from SD card to thermostat

Use the SD card to transfer customized settings to or from the thermostat. Insert the SD card into the thermostat only from Home or Default Display.

  1.  Insert the SD card into the slot located on top of the thermostat where indicated. (SD icon begins flashing).
    Note: Copy and Paste keys appear.
  2. Press Paste to copy the settings from SD card to the thermostat.
  3. Press Copy to transfer the settings from the thermostat to the SD card.
  4. Press Done to complete process. Note: The thermostat SD card display remains active until the user selects Cancel or Done and removes SD card (or menu reverts to Default Display).

TPEXCTO COMPATIBLE SENSORS

The following T12000 Series compatible sensors are available from PECO. Using information found on the last page of this document, contact a service representative to learn more about PECO sensors or to place an order.

PECO PRODUCTS Model Number Part Number Terminal T12000 T12500
Indoor Remote Sensor SP155-017 69308 S1 ü ü
Occupancy Sensor SB200-001 68375 S2 ü ü
Outdoor Remote Sensor 70327 S3 ü ü

For a complete description of sensors, terminal connections, and wiring diagrams, see the “Performance PRO T12000 Series Installation Guide.

T12000 SERIES PRODUCT SPECIFICATIONS

  • Temperature Control Range: 50° to 90° F (10° to 32° C)
  • Differential: 1° F (0.5°C)
  • Input Power: 24 VAC (20-30 VAC) 50/60Hz (+/-10%) or AA alkaline batteries (both recommended); 5mm terminals accept 14-24 AWG stranded or solid wire.
  • Output Ratings: 20-30 VAC
  • 0.02-1.0A per terminal; W1 (B/O), W2 (AUX), G, A, E, Y1, Y2.
    Note: Collectively, total current draw must not exceed 2.5A.
  • Operational Temperature: 0° to 120° F (-17° to 48°C)
  • Shipping Temperature: -20° to 130°F (-29°to 54°C)
  • Operating Humidity: 5% to 95% RH, non-condensing
  • Physical dimensions: T12000/T12500 Thermostat: 4.3” H x 5.7” W x 1.3” D with 4” x 3” / 12 square inches viewable liquid crystal display (LCD)

Automation and Controls Division of PECO, Inc.
PO Box 82189, Portland, OR 9728 Phone: 503-233-6401 | 800-874-8547
E-mail: [email protected]
www.pecomanufacturing.com
Copyright 2010. PECO, Inc. All Rights Reserved. P/N 70479 32202268 REV 00 09/10 PECO is a registered trademark of PECO, Inc. The PECO Performance PRO and the PECO logo are trademarks and/or service marks of PECO, Inc.

REFERENCE:

DOWNLOAD MANUALS:

Peco T12000 Non Programables Thermostat Operating Manual

OTHER MANUALS:

Peco T12000 Non-Programmable Thermostat Quick Start Guide

Peco T12000 Non-Programmable Thermostat Installational Guide

peco-logo

Peco T12000 Non Programables Thermostat Operating Manual


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *