NEOMITIS RTE1D PROGRAMMABLE ROOM THERMOSTAT
PACK CONTAINS
INSTALLATION
Recommended locations for your thermostat.
To ensure that your thermostat provides accurate readings and controls effectively, it must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold draughts, etc. Important: The thermostat measures the temperature of the place where it is installed. It does not take into account the temperature differences that may exist between different locations in the house if the temperature is not uniform.
INSTALLING BATTERIES
- Remove the batteries cover which is placed on the front of the thermostat.
- Insert the 2 batteries AA supplied. Note the correct polarity according to the engraving on the thermostat when inserting the batteries.
- Replace the batteries cover.
MOUNTING OF WALL MOUTING PLATE
- Unscrew the 2 screws under the thermostat.
- Remove the wall plate from the thermostat.
- Secure the wall plate with the two Screws provided using the horizontal and vertical holes.
WIRING
MOUNTING OF THE THERMOSTAT
- Replace the receiver on the wall mounting plate.
- Secure the receiver by screwing the both locking screws under the receiver.
INSTALLER SETTINGS
ADVANCED INSTALLER SETTING
Access
Move the mode slider to position. Select the Programming slider position and press Enter for 5 seconds to go into the dedicated installer setting.
Set 12/24 hours clock
- The pre-set value is 12 hours clock.
- Rotate the dial to change to “24 hr”.
- Then save by pressing Enter or move the Programming slider.
Enable/disable automatic summer/winter change over
- The summer/winter change will be performed automatically by the room thermostat.
- Press and hold Enter for 5 seconds to access the setting mode ON appears on the display.
- Rotate dial to the left to select “0ff”, to the right to select “On”.
- Then save by pressing Enter move the Programming mode.
Set C/’F temperature
- The pre-set temperature is Celsius (C).
- Rotate the dial to change to degree Fahrenheit.
- Then save by pressing Enter or move the Programming slider.
Set calibration
- Rotate the dial to adjust the calibration to the desired value.
- Then save by pressing Enter or move the Programming slider.
Program lock
- Rotate the dial to ON and locked.
- Then save by pressing Enter or move the Programming slider.
Select 2 points/TPI
- Rotate the dial to change to 2 points control algorithm.
- Then save by pressing Enter or move the Programming slider.
TROUBLESHOOTING
Display disappears on thermostat.
- Check batteries.
- Replace the 2 batteries. Only use alkaline 1.5V AA (LR6) batteries.
- Do not use rechargeable batteries.
The heating does not come on or does not go off.
- Your room thermostat may have been set up close to a source of heat or on a cold wall-put it in a recommended location (see the “Installing” section on page 2 for these locations).
- Check that the radio communication works between the thermostat and the receiver.
- Check if the boiler controlled by the programmable room thermostat is properly connected to the receiver.
You want to change the operating mode but when you move the mode slider nothing happens.
- If the lock symbol is being displayed, then the thermostat is locked.
- Unlock the thermostat by following the instructions for doing so in the “program lock” section (see page 4).
The thermostat is in Auto Mode but programs are not being executed by the boiler:
- Ensure that the thermostat is in good working condition.
- Change the batteries.
The radio link between the thermostat and the receiver is lost.
- Check the battery level status.
- Check that the radio communication works between the thermostat and the receiver.
- If the radio communication does not work between the receiver and the thermostat
- Conduct RF Test (see page 3).
- Repeat the pairing between the thermostat and receiver (reter to the pairing proce- dure on page 3).
The thermostat does not control properly.
- Thermostat sensor may be influenced by a source of heat or cold.
- Check that the radio communication works between the thermostat and receiver.
- If the problem persists, contact your installer.
TECHNICAL SPECIFICATIONS
- Power supply: 2 alkaline 1.5 V AA (LR6) batteries.
- Manual temperature setting range: from +5°C to +30°C.
- Battery life: approx. 2 years.
- Radio frequency: 2,4035 Ghz/ 2,4055 Ghz /2,4075 Ghz
- Maximum RF power transmitted: <1mW
- Power supply: 230V~50/60Hz.
- Relay outputs: 5(2)A.
- Rated impulse voltage: 4000V.
- Micro-disconnection: Type 18.
- Pollution degree: 2.
- Automatic action: 100,000 cycles.ac
- Class I.
Environment
- Operation temperature: 0°C to +40°C.
- Storage temperature: from -10°C to +60°C.
- Humidity: 80% at +25°C (without condensation)
- Protection rating: IP30.
Manufactured by: Neomitis Ltd ([email protected])
EU declaration of conformity: We hereby declare under our sole responsibility that the products described in these instructions comply with the provisions of Directives and harmonized standards listed below
- LVD 2014/35/EU EN60730-1/EN60730-2-9/ EN62311;
- EMC 2014/30/EU EN60730-1/ EN60730-2-9;
- ROHS 2011/65/EU EN50581;
- and are manufactured using processes that are certified ISO 9001: 2008.
WEEE
The on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/ EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.
REFERENCE
DOWNLOAD MANUAL
NEOMITIS RTE1D PROGRAMMABLE ROOM THERMOSTAT INSTALLATION INSTRUCTION
OTHER MANUALS
NEOMITIS RTE1D PROGRAMMABLE ROOM THERMOSTAT OPERATING Instruction
NEOMITIS RTE1D PROGRAMMABLE ROOM THERMOSTAT INSTALLATION INSTRUCTION
Leave a Reply