Meitay-tec FMT-24-SUPER-PROG Programmable Thermostat
Technician Settings
Temperature limits and Offset
- Press the ON button to turn the thermostat ON or OFF (The word “ON” or “OFF” will appear on display)
- Adjust the set-point temperature to 50oF.
- Press and hold the SELECT button (5 sec.) – “COOL” and the temperature limit for cooling will appear on display.
- Adjust the temperature limit for cooling (Limit Cool) using the “+” and “-“ buttons.
- Press the SELECT button again – “HEAT” and the temperature limit for heating will appear on display.
- Adjust the temperature limit for heating (Limit Heat) using the “+” and “-“ buttons.
- Note: Limit Heat should be higher than Limit Cool).
- Press the SELECT button again – the OFFSET temperature will appear on display (number between –6…+6). The offset is used for calibration of the measured temperature.
- Adjust the Offset for ambient temperature reading using the “+” and “-“ buttons.
- Press the SELECT button again to return to normal display.
Lock/Unlock
- Use the Lock option to prevent users from making unwanted changes.
- When the thermostat is locked, the SELECT button and the “+” and “-” buttons do not work.
- However, the users can turn the thermostat ON or OFF.
- When locked, the display will alternate between “Loc” and real time clock.
- Make sure both temperature set-points are different than 50ºF.
- Lock the thermostat – Press and hold the SELECT button (20 seconds) until “Loc” will appear on display.
- Unlock the thermostat – Press and hold the SELECT button again (20 seconds) until “UnLo” will appear on display.
Freeze Protection
- When the temperature drops below 45ºF, the thermostat will turn on the Heat and Fan outputs in order to protect the system from freezing.
- This function will be activated when the thermostat is either in On or Off position.
- The Display will alternate between ”AL” and “TEMP”
- The thermostat will return to normal mode when the temperature rises above 48ºF.
WIRING
DIP Switch Configuration
Switch | Internal/External Sensor | HP | HC | Time delay for
compressor |
||||
Internal
sensor |
External
sensor |
Heat Pump
in heat “B” |
Heat Pump
in cool “O” |
Oil/Gas
heat |
Electric
heat |
No delay | 3 Minutes | |
1 | OFF* | ON | X | X | X | X | X | X |
2 | X | X | ON | OFF* | X | X | ||
3 | X | X | ON | OFF | ON | OFF* | X | X |
4 | X | X | X | X | X | X | ON | OFF* |
5 | OFF* | ON | X | X | X | X | X | X |
6 | ON* | OFF | X | X | X | X | X | X |
Meitay-tec
- Tel: +972-3-9626462
- Fax: +972-3-9626620
- [email protected]
- www.meitavtec.com
REFERENCE:
DOWNLOAD MANUALS:
Meitay-tec FMT-24-SUPER-PROG Programmable Thermostat Wiring Diagram
OTHER MANUALS:
Meitay-tec FMT-24-SUPER-PROG Programmable Thermostat Product Specification Guide
Meitay-tec FMT-24-SUPER-PROG Programmable Thermostat Installation Guide
Meitay-tec FMT-24-SUPER-PROG Programmable Thermostat Wiring Diagram
Leave a Reply