max logo

MAX! BC-RT-TRX-CyN Radiator Thermostat

Information about this manual

Read this manual carefully before starting to use the device. Keep the manual for later consultation. If you hand over the device to other persons for use, please hand over the operating manual as well.

Attention!
This indicates a hazard.
Note.
This section contains important additional information!

Safety instructions

Function

MAX! House solution
This is the solution for the entire house. With a MAX! Cube, all settings of connected devices in your house can comfortably be made via the MAX! software

By using the MAX! Cube, several MAX! Radiator solutions and MAX! Room solutions can be connected to a new MAX! House solution in a new installation. In this installation, the MAX! Eco Switch can optionally be integrated.

MAX! Room solution

Device overviewMAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 1

Display content in normal mode
The setpoint temperature is displayed during normal operation, along with the mode. In the example, the MAX! Radiator Thermostat is in automatic mode (Auto) and the comfort temperature ( MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 2) of 21.0°C is set. The antenna symbol ( MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 3) indicates that the connection to the taught-in component has been establishedMAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 4

Start-up

Inserting (replacing) batteries
In the initial state, the batteries are already inserted. Simply remove the insulation strip.

To replace the batteries, please proceed as follows:

MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 5

After inserting batteries, the radiator thermostat has to be mounted on the radiator (see sec. “6.2 Installation on the radiator” on page 11). The radiator thermostat starts an adapting run afterwards (see sec. “6.3 Adaption run” on page 15).

Information

Installation on the radiator
The MAX! Radiator Thermostat is easy to install and can be done without draining heating water or intervening in the heating system. No special tools are required, nor does the heating have to be switched off. The union nut attached to the radiator thermostat can be used universally and without accessories for all valves with a thread size of M30 x 1.5 from the most popular manufacturers such as

By means of the adapter in the delivery, the device can also be installed on radiator valves of type Danfoss RA.

Removing the old dial
Rotate the thermostat dial to the maximum value (1) (anti- clockwise). The thermostat dial then no longer presses against the valve spindle, making it easier to remove. There are different ways of fixing the position of the thermostat dial:

MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 7

Danfoss RA adapter

The provided adapter is required for installation on Danfoss RA valves. The Danfoss valve bodies have elongated notches (G) around their circumference (see arrow), which also ensure that the adaptor is properly seated when it snaps on. Please ensure that you do not trap your fingers between the two halves of the adapter! During installation, please ensure that the pins inside the adapter (H) are lined up with the notches (G) on the valve. The RA adapter has been manufactured with pre-tension in order to provide a better seat. Use a screwdriver during installation if necessary, and bend it open slightly in the vicinity of the screw. Ensure that the adapter is properly clipped on. After clipping onto the valve body, please attach the adapter using the provided screw and nut.MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 8

Support ring
The valves from different manufacturers may have tolerance fluctuations that make the radiator thermostat more loosely seated on the valve. In this case, the provided support ring (I) should be placed into the flange before mounting the radiator thermostat.MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 9

Adaption run
Once the batteries have been inserted, the motor reverses; meanwhile, “InS” and the activity symbol ( MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 10) are displayed. As soon as “InS” is displayed without the activity symbol ( MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 10), the radiator thermostat can be mounted. This is followed by an adapting run (“AdA”) to adapt the thermostat to the valve.

Teaching-in
In order to be able to use the MAX! Radiator Thermostat in your installation, you must teach it in first. The teach-in procedure depends on the system variant used. Choose your system variant (House or Room solution) and follow the instructions below.

MAX! House solution
In the MAX! House solution all settings and programming (e.g. week programs) can be made via the MAX! software.

MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 11

MAX! Room solution

MAX! -BC-RT-TRX-CyN -Radiator- Thermostat- 12

After teaching-in has been successful, the display returns back to normal display.

Auto/Manu

Boost

If, for example, you arrive home earlier than usual, the boost function will help you to heat the room up quickly. When activating the boost function, the heating valve is immediately opened to 80 % for 5 minutes (factory setting). The heating of a room takes longer than 5 minutes, but the heat given off by the radiator can be felt immediately.

Comfort and reduction temperature

Child safeguard/operating lock
Operation of the device can be locked to avoid settings being changed unintended (e.g. through involuntary touch).

Configuration of the MAX! system

Restore factory settings

The factory settings of the MAX! Radiator Thermostat can be restored manually. Restoring the factory settings deletes all settings and information about taught-in devices. Before restoring the factory settings of the MAX! Radiator Thermostat, first delete the device from the local MAX! software if you use the radiator thermostat  in connection with a MAX! Cube.

LE D flashing sequences and transmission behaviour

Error code on the display Description/ problem Solution
Battery symbol ( ) Battery voltage too low Replace batteries
F1 Valve drive sluggish Check the installation; check whether the pin on the heat- ing valve is stuck
F2 Actuating range too wide Check the fastening of the actuator
F3 Adjustment range too small Check the heating valve; check whether the valve pin is jammed
F4 Device already taught-in to a MAX! Cube or MAX! Wall Thermostat+ Make sure the device is no longer taught-in to the Cube (in the software) or the Wall Thermostat+ and perform a reset. Then you can teach-in the device again.
Slowly flash- ing antenna symbol() Connection to taught-in MAX! components lost Check the power supply and the batteries of taught-in MAX! components
dCE + quickly flashing an- tenna symbol

()

Duty cycle limit reached The device can resume radio communication after a wait- ing time of approx. one hour
Error code on the display Description/ problem Solution
LOC Operating lock ac- tivated Deactivate the operating lock (see sec. “11 Child safe- guard/operating lock” on page 22)
CAL Routine descaling is active Automatic function
Battery sym- bol + F9 Battery voltage too low, valve moved to error position replace batteries of radiator thermostat
Battery sym- bol + 10 Battery voltage much too low replace batteries of radiator thermostat
Syn Attempts to syn- chronize with known MAX! de-

vices

/
trd Transceiver module

defect

Replace device
tSd Temperature sen- sor defect or out of

range

replace device or operate device in current tempera-

ture range

Maintenance and cleaning

The product does not require any maintenance. Enlist the help of an expert to carry out any repairs. Clean the product using a soft, lint-free cloth that is clean and dry. You may dampen the cloth a little with lukewarm water in order to remove more stubborn marks. Do not use any detergents containing solvents, as they could corrode the plastic housing and label.

Information about radio operation
Radio transmission is performed on a non-exclusive transmission path, which means that there is a possibility of interference occurring. Interference can also be caused by switching operations, electrical motors or defective electrical devices. The range of transmission within buildings can differ greatly from that available in the open air. Besides the transmitting power and the reception characteristics of the receiver, environmental factors such as humidity in the vicinity have an important role to play, as do on-site structural/screening conditions. eQ-3 AG hereby declares that this device complies with the essential requirements and other relevant regulations of Directive 1999/5/EC. You can find the full declaration of conformity at www.eQ-3.de.

Technical data

Max. number of devices to be taught-in:

MAX! House solution

MAX! Room solution:

Do not dispose of the device with regular domestic waste!

REFERENCE

DOWNLOAD MANUALS:

MAX! BC-RT-TRX-CyN Radiator Thermostat Operating manual

max logo

MAX! BC-RT-TRX-CyN Radiator Thermostat Operating manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)