LUX-LOGO

Lux TX700U 7-Day Universal Programmable Thermostat 

Lux-TX700U-7-Day-Universal-Programmable-Thermostat-PRODUCT

WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Procter & Gamble Company.

IMPORTANT!

SYSTEM COMPATIBILITY

This thermostat can be used with most 24 volt: gas, oil, Millivolt, electric heating and cooling systems, including heat pumps with an aux/emerg heat element.
It cannot be used with: 120/240 volt heating elements (without a transformer), or on heat pumps that have two compressor stages (Y2). Ask your dealer for other LUX thermostats to control those systems.

CAUTIONS AND WARNINGS:

REMOVAL OF OLD THERMOSTAT

  1. Turn OFF the electricity to all heating and cooling components. Do not turn the electricity back on until all work is completed.
  2. Write down the letters printed near each wire terminal that is used, and also the color of each wire that is connected to it. Self-adhesive wire labels are also enclosed.
  3. Carefully remove the wires one at a time, and bend them in a manner so that they do not fall back inside the wall. Do not allow bare wire ends to touch each other.

INSTALLATION OF NEW THERMOSTAT

Use the wiring diagrams shown on the back of this installation sheet to find the closest match to your particular heating and/or cooling system. Please read ALL of the Wiring Diagram Notes that are shown above the connection diagrams, to avoid causing damage to your system or the new thermostat.

  1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present.
  2. Fill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’s normal operation.
  3. Route the wires through the opening in the new thermostat base plate, and install the mounting screws.
  4. If the previous holes cannot be used, hold the thermostat base against the wall so that it appears straight and level (position the base for best appearance) and mark for the new screw holes. Attach the base to the wall using the screws provided (use the supplied plastic anchors if needed when mounting to a soft material such as drywall).
  5. When attaching the wires to the thermostat, please ensure that the bare wire ends are held ALL the way into the terminal block while the screw is being tightened, and be careful not to over tighten them, as they only need to be snug.

COMPLETE THE INSTALL

GAS / ELEC CIRCUIT BOARD OPTION (“G” TERMINAL FAN OPERATION)

This setting is a plastic shorting cap called a jumper. This jumper must remain installed, and set to either GAS or ELECTRIC for your system to work properly. This setting changes how your system’s blower fan (if applicable) is controlled while the thermostat is in HEAT or EMERG HEAT mode when the Fan switch in the AUTO position. This setting does not affect the fan operation while in COOL mode. When set to “GAS”, the blower fan is controlled solely by the heating system itself. Systems that would typically use the “GAS” setting would be: natural gas, propane, or oil furnaces, and boilers.
NOTE: If your blower fan does not operate properly after installation, move the Gas / Electric option to the “Electric” setting.
When set to “ELEC”, the blower fan is controlled directly by the thermostat. This setting is required for heating systems that do not control their own fan, such as HEAT PUMPS, and units that only  have an electric-resistive heating element as the heat source.

Lux-TX700U-7-Day-Universal-Programmable-Thermostat-FIG.1

FRONT PANEL CONTROLS

SYSTEM CONFIGURATION AND SETUP OPTIONS

SET DAY AND TIME

Place the Set Slide Switch into the DAY/TIME position. With the day flashing, press UP or DOWN to set the day of the week. Press NEXT and the clock time will start flashing. Use UP or DOWN to set the time, making sure the AM/PM indication is correct. Holding the UP or DOWN buttons will make the clock digits scroll rapidly. Return the Set Slide switch to the RUN position when finished.

BASIC HEATING AND COOLING OPERATION

Basic operation of your heating or cooling system can be obtained with the Set Slide Switch in the RUN position and choosing either HEAT or COOL on the System Mode switch. The temperature can be adjusted using the UP and DOWN buttons. When the thermostat is first powered up, it will follow a default temperature routine that is preset from the factory. Alternatively, you can use the HOLD button to maintain a fixed Set Temperature.

DOWNLOAD FULL INSTRUCTION MANUAL FROM OUR WEBSITE

This sheet contains basic installation steps and setup instructions. There are additional topics covered in greater detail, such as adjustable set temperature limits, keypad lockout, and the air filter monitor, in the full version of the instruction manual for this thermostat product. The full PDF version of this manual can be downloaded at http://www.luxproducts.com. Click on SUPPORT, then INSTRUCTION MANUALS.

TEMPERATURE PROGRAMMING

By default, this thermostat has 4 separate program periods for both Heat and Cool modes, they are:

MORN, DAY, EVE, and NITE. Each period ends at the start time of the next upcoming period. The Heat temperature programs are set while the mode switch is in the HEAT position, and the Cool temperature programs are set while the mode switch is in the COOL.
NOTE: If the thermostat is configured to use only 2 periods per day (instead of the factory default of 4 periods per day), the thermostat will only use the DAY and NITE period designations. The MORN and EVE periods will not be used or visible on the screen.

TO SET A TEMPERATURE PROGRAM: Choose either HEAT or COOL mode. Move the Set Slide switch to the TEMP PROG position. Programming will start with Monday. Use the UP/DOWN buttons to adjust the start time for the MORN period, and then press the NEXT button to advance. Use the UP/DOWN buttons to adjust the set temperature for the MORN period, and then press the NEXT button to advance. Now adjust the start time and set the temperature for the DAY period, pressing the NEXT button after each item to advance. Continue with these same steps to adjust the start times and set temperatures for the EVE and NITE program periods. When the last period is finished for each day (or group of days), the thermostat will advance forward into the next day (or group of days).
NOTE: If a temperature program routine is not desired, you may change ITEM #02 in the Setup Options to “3” for manual non-programmable. Return the Set Slide switch back to the RUN position when you are finished.

EMERGENCY HEAT OPERATION

Emergency Heat mode is only present if the thermostat is set up for a Heat Pump configuration (SETUP MENU ITEM #06 set to “HP”). With the System Mode switch in the HEAT position and the Set Slide switch in the RUN position, one single press of the EMER button will activate Emergency Heat mode. A single press again will deactivate Emergency Heat mode, and return back to regular Heat mode. While in Emergency Heat mode, the word “EMER” will be present in the middle portion of the display screen. If a mains power loss occurs while in Emergency Heat mode, the thermostat will continue to remain in Emergency Heat mode even after the mains power comes back on.
Emergency Heat mode will prevent the first stage (outdoor unit) of your heat pump system from turning on, and uses only the “W2” wire terminal (Auxiliary Heat) as the primary heating source. This not only prevents the heat pump from wasting energy when outdoor temperatures are too low to provide efficient operation, but it can also prevent permanent mechanical damage to the heat pump unit itself if outside temperatures are below the manufacturer’s recommendations for running the outdoor unit. As every heat pump has different operating characteristics, you should always refer to your particular heat pump’s literature to determine when the manufacturer recommends changing over to Emergency Heat mode. In general for most heat pump systems, use Emergency Heat mode whenever the outside temperature is less than 32F degrees.

WIRING DIAGRAM NOTES

TECHNICAL ASSISTANCE

If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you still require assistance, please contact our Technical Assistance department at 856-234-8803 during regular business hours between 8:00 AM and 4:30PM Eastern Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproducts.com. Our website offers you troubleshooting guides and answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.

Lux-TX700U-7-Day-Universal-Programmable-Thermostat-FIG.2 Lux-TX700U-7-Day-Universal-Programmable-Thermostat-FIG.3

REFERENCE:

Download Manual: Lux TX700U 7-Day Universal Programmable Thermostat INSTALLATION MANUAL

LUX-LOGO

Lux TX700U 7-Day Universal Programmable Thermostat INSTALLATION MANUAL

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)