Lennox L3021H Non-Programmable Thermostat
Description
The Lennox ComfortSense 3000 Series model L3021H non-programmable electronic thermostat is easy-to-use, has a large, easy-to-read display, and provides excellent temperature control. The thermostat also includes a programmable filter change reminder, and a system check indicator which will notify the user of the need for equipment service.
Thermostat model L3021H is suitable for heat pump, and single−stage heat/single cool applications that are matched with a gas or electric furnace.
General
These instructions are intended as a general guide and do not supersede local codes in any way. Consult authorities having jurisdiction before installation.
Check equipment for shipping damage. If you find any damage, immediately contact the last carrier.
Introduction
This document describes the operation of the Lennox model L3021H thermostat. Refer to the installation manual for instructions regarding installation and wiring of the thermostat.
Initial Thermostat Power-up
When power is initially applied to the thermostat, the display will appear as shown in figure 1.
All display segments are momentarily activated. This occurs as a normal part of thermostat initialization. Within a few seconds, the display will appear as shown in figure 2 (figure shows temperature in Fahrenheit units).
Figure 2 illustrates the HOME screen. Note that an indoor room temperature of 70°F is initially displayed. After about 1 minute of warm−up time, the actual room temperature will be displayed. HEAT mode is the system default (as indi-cated in the SYSTEM box at lower right).
A pale blue display backlight turns on each time a key is pressed; then off 8 seconds after the last key is pressed.
Heating Control
The HEAT button is located behind the small door on the right−hand side of the thermostat. See figure 3.
Normal Heat Mode
In normal heat mode, both the heat pump and the backup heat source are used to provide heat. If the thermostat de-tects that the heat pump is not able to provide enough heat (as may be the case in very cold weather), then the backup heat source is activated.
Emergency Heat Mode
In emergency heat mode, only the backup heat source provides heat the heat pump is disabled. The backup heat source is activated only when there is a heat demand.
Enabling and Disabling Heat Mode
Use the HEAT button to select normal heat mode, emer-gency heat mode, or to disable heat modes as desired. If the thermostat is in off mode, normal heat mode is enabled when the HEAT button is pressed. This is indicated by HEAT in the SYSTEM box as shown in figure 4.
If the thermostat is in normal heat mode when the HEAT button is pressed, then emergency heat mode is enabled. This is indicated by EMG. HEAT in the SYSTEM box as shown in figure 5.
If the thermostat is in emergency heat mode when the HEAT button is pressed, then heat modes are disabled. This is indicated by OFF in the SYSTEM box as shown in figure 6.
Heating Demand
The thermostat must be in either normal or emergency heat mode in order to properly control the heating equipment. When in either heat mode, if the actual temperature is lower than the temperature setpoint, a heating demand is detected by the thermostat. The thermostat will then activate the heating equipment to satisfy the demand. Heating operation is indicated by a flame icon in the SYSTEM box as shown in figure 7.
When the actual temperature rises above the temperature setpoint, the flame icon will disappear. This indicates that the heating demand has been satisfied and that the heating equipment has been turned off.
NOTE − The heat pump is activated for at least 4 minutes if no buttons are pressed during the demand interval. The backup heat source is activated for at least 3 minutes if no buttons are pressed during the demand interval.
Heat pump operation is locked out for 5 minutes after a demand has been satisfied. If another heat pump demand occurs during this 5−minute interval, the flame icon will flash; however, the heat pump will not run until the 5-minute delay has elapsed.
Cooling Control
The COOL button is located behind the small door on the right-hand side of the thermostat. See figure 3.
Enabling and Disabling Cool Mode
Use the COOL button to enable or disable cool mode as necessary. If the thermostat is in off mode, cool mode is enabled when the COOL button is pressed. This is indi-cated by COOL in the SYSTEM box.
If the thermostat is in cool mode, cool mode is disabled when the COOL button is pressed. This is indicated by OFF in the SYSTEM box.
Cooling Demand
The thermostat must be in cool mode in order to properly control the cooling equipment. When in cool mode, if the room temperature is higher than the temperature setpoint, a cooling demand is detected by the thermostat. The thermostat will then activate the cooling equipment to satisfy the demand. Cooling operation is indicated by a snowflake icon in the SYSTEM box as shown in figure 8. When the actual temperature drops below the temperature setpoint, the snowflake icon will disappear. This indicates that the cooling demand has been satisfied and that the cooling equipment has been turned off.
NOTE − The cooling equipment is activated for at least 4 minutes if no buttons are pressed during the demand interval. Cooling equipment operation is locked out for 5 minutes after a demand has been satisfied. If another cooling demand occurs during this 5−minute interval, the snowflake icon will flash; however, the cooling equipment will not run until the 5−minute delay has elapsed.
Adjusting Temperature Setpoint
The temperature setpoint represents the desired temperature of the space around the thermostat. The default temperature setpoint is 70°F. To adjust the setpoint, press the UP or DOWN arrow keys to the right of the display screen. The existing setpoint will be displayed just below the actual room temperature as shown in figure 9. Use the UP or DOWN arrow keys to adjust the setpoint up or down. The setpoint will increase by 1°F each time the UP key is pressed. The setpoint will decrease by 1°F each time the DOWN key is pressed.
After the desired setpoint is reached, the HOME screen will reappear after about 8 seconds.
Fan Control
The FAN button is located behind the small door on the right-hand side of the thermostat. See figure 3. The FAN button can be used to select either continuous fan mode or auto fan mode.
If continuous fan mode is enabled, the fan will run continu-ously regardless of whether the heating or cooling equip-ment is running. Also, ON will be displayed in the FAN box as shown in figure 10.
If auto fan mode is selected, the fan will only run when the heating or cooling equipment is running. In this case, AUTO will be displayed in the FAN box as shown in figure 11.
To change from continuous to auto fan mode and vice ver-sa, press the FAN button. Also note the presence of a fan icon in the FAN box. This icon indicates that the fan is running.
Filter Reminder
The L3021H thermostat includes a filter reminder feature. The filter reminder can be set for 1, 3, 6, or 12−month inter-vals. The SETTINGS button, located behind the door on the right−hand side of the thermostat is used to set the filter reminder interval. See figure 3. Press the SETTINGS but-ton from the HOME screen to display the Filter Reminder Settings screen as shown in figure 12.
The default setting for the filter reminder is 0, which dis-ables the function. Use the UP arrow while in the Filter Re-minder Settings screen to select the desired interval be-tween reminders. It may be necessary to press the UP arrow several times to access the desired setting. The HOME screen will reappear about 10 seconds after the ar-row key has been pressed for the final time.
After the programmed interval has elapsed, the FILTER re-minder will be displayed as shown in figure 13. After the fil-ter has been changed, reset the filter reminder by pressing the SETTINGS button for 4 seconds. The screen will blink for a few moments to indicate that the timer has been reset.
Balance Point
NOTE − The balance point is only available with the outdoor sensor. If the optional outdoor sensor (X2658) is connected to the thermostat, balance point adjustment is available. The balance point feature allows the measured outdoor tempera-ture to govern operation of the heat pump and backup heat source.
Use the SETTINGS button to access the balance point setting. If the outdoor sensor is attached to the thermostat, press the SETTINGS button twice to access the Balance Point Settings screen (see figure 14).
The balance point can be set at any temperature between 1°F and 55°F (−17°C to 13°C). A balance point setting of zero disables the balance point function (in this case, the thermostat behaves as if no outdoor sensor is attached). The default balance point setting is 55°F.
To adjust the balance point up or down, press the UP or DOWN arrow keys to the right of the display screen. The balance point setting will increase by 1°F each time the UP key is pressed. The balance point setting will decrease by 1°F each time the DOWN key is pressed.
After the desired balance point is reached, the HOME screen will reappear after about eight seconds.
NOTE − The balance point feature allows the temperature to rise or fall 3°F above or below the setpoint. This prevents excessive cycling of the equipment when the outdoor temperature is near the balance point. For example, if the bal-ance point is 40°F and the actual outdoor temperature is 35°F, the outdoor temperature must rise to 43°F before equipment adjustment occurs. Conversely, if the balance point is 40°F and the actual outdoor temperature is 45°F, the outdoor temperature must drop to 37°F before equipment adjustment occurs.
Service Indicator
When abnormal equipment operation is detected, the SERVICE indicator will flash on the upper-right corner of the screen. This indicates that the equipment requires ser-vice from a qualified service technician. The SERVICE in-dicator is shown in figure 15.
Thermostat RESET
Under some abnormal conditions, it may be desirable to reset the thermostat to its default condition. The RESET button can be used to return the unit to normal operation after an occurrence such as an electrical storm or power outage.
The RESET button is an unlabeled, recessed button located behind the door on the right−hand side of the thermostat, just below the SETTINGS button. The RESET button is visible in figure 3. Use a paper clip or small pencil to press the RESET button. After the RESET button is pressed, the thermostat settings will return to the defaults listed in the Default Settings section.
Default Thermostat Settings
Default Thermostat settings are in table 1.
Table 1. Default Thermostat Settings
Mode | Heat |
Setpoint | 70°F (or 21°C) |
Fan | Auto |
Filter Reminder | OFF (reminder setting = 0) |
Equipment Protection Timers | reset back to zero |
Technical Specifications
Thermostat Type
Electronic nonprogrammable thermostat for 1H/1C, heat pump with electric or gas backup heat source, non−power robbing applications.
Power Supply Range
18VAC − 30VAC (24VAC nominal), 60Hz
Temperature Display
- Display Scale: Fahrenheit or Celsius user selectable (via DIP switches)
- Display range: 35°F (2°C) to 99°F (37°C)
- Display resolution: 1°F (1°C)
- Display Accuracy: +/−1°F
Temperature Measurement Range
- Measurement Scale: Fahrenheit
- Measurement Range: 35°F to 99°F
- Measurement Resolution: 0.5°F
- Measurement Accuracy: +/−1°F
- Field Offset: via DIP switches to +/−3°F
- Sampling Method: temperature measurements sampled every 15 seconds. Displayed temperature is the average of the last four measurements.
Temperature Setpoint Range Setting range: 50°F (10°C) to 90°F (32°C) Setting resolution: 1°F (1°C)
Temperature Control Band
Fan Control
AUTO or ON modes.
Backup Heat Source Selection
Electric or gas furnace, selectable via DIP switch #5 (Aux or Dual, respectively). See also Thermostat Output sec-tion.
I/O Relays
All thermostat relays are latching type to minimize power consumption. See table 2.
Table 2. L3021H Terminal Designations
Connections | Description |
O | Reversing valve, cool active |
B | Reversing valve, heat active |
R | 24VAC |
G | Fan control |
Y1 | First stage cooling/heating, compressor generated |
W1 | Auxiliary heating, furnace generated |
L | Service Indicator |
C | 24VAC common |
E | Emergency heat |
T | Outdoor temperature sensor connection 1 |
T | Outdoor temperature sensor connection 2 |
- Equipment Protection Timers Minimum Compressor OFF time: 5 minutes
- Minimum Compressor ON time: 4 minutes
- Minimum Furnace ON time: 3 minutes
- Minimum backup furnace cycle time (elapsed time between any furnace activation and the next furnace activation): 6 minutes.
- Minimum elapsed time between any compressor activation and the next compressor activation: 6 minutes.
NOTE − All protection timers (except the compressor OFF timer) can be overridden if a heating or cooling demand is initiated or terminated using the UP, DOWN, HEAT, or COOL buttons.
Equipment Protection Override
Both the minimum compressor OFF timer and the mini-mum equipment cycle timer can be overridden by pressing and holding either the HEAT or COOL button down for 4 seconds.
Over−Temperature Protection
Thermal mechanical switch opens W1 at 93°F+/−6°F.
Filter Reminder
Settings of 0 (Off), 1, 3, 6 or 12 months are available. When programmed time has elapsed, a FILTER indicator is displayed.
Balance Point
0°F (OFF) to 55°F, user selectable.
Service Reminder
The SERVICE indicator is displayed only under the follow-ing conditions:
- if the thermostat Y1 terminal has been activated with 24VAC for at least 5 minutes, AND the L terminal is shorted to the R terminal;
OR - if the thermostat Y1 terminal has been activated with 24VAC for at least 5 minutes, AND the L terminal is shorted to the C terminal.
Power Loss/Recovery
Thermostat memory is retained for a minimum of 24 hours during a power loss (includes retention of programmed temperature setpoint, heat/cool and fan mode settings, fil-ter reminder status, and equipment protection timers). Af-ter 24 hours of power loss, programmed settings will be lost and replaced with default settings.
IMPORTANT Power must be applied for at least six consecutive hours prior to a power loss in order for memory to be retained for the specified time.
LCD Backlight
Activated for 8 seconds when any key is pressed.
NOTE − During an electrical storm or similar disturbance, the backlight may activate for a few seconds. This is nor-mal and will no longer occur after the electrical disturbance has passed.
Thermostat Operating Conditions
35°F to 105°F, 5% to 90% RH
Thermostat Storage Conditions
40°F to 185°F, 5% to 95% RH
Thermostat Output Table
Table 3 (see page 9) provides details of the L3021H ther-mostat output states for various input conditions.
Table 3. Thermostat Output States
Condition | W1 | Y1 | G | O | E |
Electric Heat Backup − No Outdoor Sensor | |||||
small heat demand | X | X | |||
large heat demand | X | X | X | ||
emergency heat demand | X | X | |||
cool demand | X | X | X | ||
no demand | dc | ||||
Gas Heat Backup (Dual Fuel) − No Outdoor Sensor | |||||
small heat demand | X | X | |||
large heat demand | X | ||||
emergency heat demand | X | ||||
cool demand | X | X | X | ||
no demand | dc | ||||
Electric Heat Backup − Outdoor Sensor Attached | |||||
small heat demand (BBP) | X | X | |||
large heat demand (BBP) | X | X | X | ||
small heat demand (ABP) | X | X | |||
large heat demand (ABP) | X | X | |||
emergency heat demand | X | X | |||
cool demand | X | X | X | ||
no demand | dc | ||||
Gas Heat Backup (Dual Fuel) − Outdoor Sensor Attached | |||||
small heat demand (BBP) | X | ||||
large heat demand (BBP) | X | ||||
small heat demand (ABP) | X | X | |||
large heat demand (ABP) | X | ||||
emergency heat demand | X | ||||
cool demand | X | X | X | ||
no demand | dc | ||||
NOTE −
• X = output is activated with 24VAC • dc: does not care (output can be in either state, i.e., either active or inactive) • BBP: outdoor temperature is below balance point • ABP: outdoor temperature is above balance point • small heat demand: temperature is between (setpoint − 1.5°F) and (setpoint − 0.5°F), and 30-minute upstage timer has not expired (see Normal Heat Mode graph, figure 16) • large heat demand: temperature is below (setpoint − 1.5°F), or 30-minute upstage timer has expired (see Normal Heat Mode graph, figure 16) • the state of the B terminal is opposite the state of the O terminal. • data above are tabulated for AUTO fan setting. If fan setting is ON, the fan is activated in all cases. |
References: