Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-featured

Laticrete RSW-XX-YY-ZZ Smart WIFI Thermostat Operating Manual

Laticrete-logo

Laticrete RSW-XX-YY-ZZ Smart WIFI Thermostat 

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-35

Pack Contents

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-1

Safety Information

  • The STRATA_HEAT™ Wi-Fi Thermostat must be installed by a qualified electrician. It requires a permanent 110V – 240V AC, 60Hz supply. The STRATA_HEAT Wi-Fi Thermostat contains a Class A GFCI with a 5mA trip level and the wiring must conform to the local electrical code.
  • Isolate the STRATA_HEAT Wi-Fi Thermostat from the main supply throughout the installation process.
  • Install the STRATA_HEAT Wi-Fi Thermostat in an area with good ventilation. It should not be beside a window/door, in direct sunlight or above another heat-generating device (e.g. radiator or TV).
  • Ensure the distance from your router to the STRATA_HEAT Wi-Fi Thermostat is not excessive. This will ensure the wireless connection is not subject to range or interference issues once installed.
  • Conduits are only required where it is mandated by state or provincial code. Please refer to the local electrical code for compliant applications.
  • The STRATA_HEAT Wi-Fi Thermostat and its packaging are not toys; do not allow children to play with them. Small components and packaging present a risk of choking or suffocation.
  • The STRATA_HEAT Wi-Fi Thermostat is suitable for indoor use only. It must not be exposed to moisture, vibrations, mechanical loads, or temperatures outside of its rated values.
  • For safety and licensing reasons, unauthorized change and/or modification of the STRATA_HEAT Wi-Fi Thermostat is not permitted.

Step 1 – Installation

  1. Isolate the STRATA_HEAT Wi-Fi Thermostat and supply from the mains supply.
  2. Unclip the display from the power base
  3. Install a 3-1/2″ (89 mm) deep single gang or 2-gang box with mud ring in your preferred thermostat location. Pull wires (heater, supply, and sensor) through the gang box and complete terminal wiring.Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-2

Step 2 – Wiring Connections

WARNING!
The STRATA_HEAT™ WiFi Thermostat must be installed by a qualified electrician in accordance with National Electrical Code.

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-2

Wiring Connections
LOAD L1

& L2

Heater Load Max.15A (1800W/120V, 3600W/240V)
LINE L1 Supply Live (120 V)
LINE

L2

Supply Neutral (120 V) / Supply Live (240 V)
P1 & PC Probe 1 – Floor/Air Control Sensor (No Polarity) Floor or air temperature reading for scheduled control
P2 & PC Probe 2 – Limit Sensor (No Polarity)
See Table 1.0 for thermostat use cases

Wiring Connections

NOTE: The function of Probe 1, and Probe 2 from Control/Limit Sensor can be swapped in Advanced Settings; Sensors & Application.

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-5

# Use Case Control Limit Sensor
 

1

Thermostat IN room Air temperature schedule

No floor limit

Internal

Air Sensor

 

None

2* Thermostat IN/OUT of room Floor temperature schedule Floor limit P1 & PC

Floor Sensor

None
 

3

Thermostat IN room Floor temperature schedule

Air limit

P1 & PC

Floor Sensor

Internal

Air Sensor

 

4

Thermostat OUT of room Air temperature schedule No floor limit P1 & PC

Air Sensor

 

None

 

5**

Thermostat IN room Air temperature schedule

Floor limit

Internal

Air Sensor

P2 & PC

Floor Limit

 

6

Thermostat IN/OUT of room Floor temperature schedule Floor limit P1 & PC

Floor Sensor

P2 & PC

Floor Limit

 

7

Thermostat OUT of room Air temperature schedule Floor limit P1 & PC

Air Sensor

P2 & PC

Floor Limit

 

8

Thermostat IN/OUT of room Regulator schedule

No limit

 

Reg.

 

None

 

9

Thermostat IN room Regulator schedule Air limit  

Reg.

Internal

Air Sensor

 

10

Thermostat IN/OUT of room Regulator schedule

No limit

 

Reg.

 

None

 

11

Thermostat IN/OUT of room Regulator schedule

Floor limit

 

Reg.

P2 & PC

Floor Limit

 

12

Thermostat IN/OUT of room Regulator schedule

Floor limit

 

Reg.

P2 & PC

Floor Limit

Table 1.0 – Thermostat use cases

2* Recommended when the thermostat is OUT of the heated room
5** Recommended when the thermostat is IN the heated room
NOTE: For thermostat use cases 6 & 7 an additional sensor will be required.

Wiring Diagrams
Heating Load connected to STRATA_HEAT™ Wi-Fi Thermostat and Relay 25 – Max. 40 Amps

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-5

Heating Load connected to Relay 25 – Max. 25 Amps

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-5

Step 3 – Thermostat Mounting

  1. Insert fixing screws through mounting holes of the power base and tighten.Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-8
  2. Re-attach the display to the power base. You can now restore power to the circuit and power up the STRATA_HEAT™ Wi-Fi Thermostat.Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9

Follow the on-screen icons to set up your system.

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9

Step 4 – Initial Setup

  1. Download the MySTRATA_HEAT App.
  2. Open the MySTRATA_HEAT App and scan the QR Code on the STRATA_HEAT Wi-Fi Thermostat screen protector or on the reverse of the display. Follow the instructions in the App to complete the setup.Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9

Welcome to the STRATA_HEAT™ Wi-Fi ThermostatLaticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9

How to quickly change the temperatureLaticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9

  • PressLaticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9 / Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9to change your target temperature.
  • If in program mode this will set a temporary override until your next heating period. See “How to set a temporary override”.
  • If in manual mode this will set a fixed target temperature. See “How to set into Manual Mode”
  • Once the target temperature is set above the current floor/air temperature the heating indicator  Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9will appear in the top right-hand corner.

How to quickly change mode
Mode select allows you to quickly change from manual mode to program mode or simply switch the heating off.

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9

Heating

How to set up a program

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-9Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-19
Setting a “Program” allows you to set comfort temperatures at set times throughout the day. Days can be programmed individually, all days the same, or weekdays as a block and weekends as a block, the choice is yours.

How to set into Manual Mode
Setting into “Manual” mode allows you to set a fixed target temperature for the thermostat to achieve. The thermostat will continue to maintain this temperature until another operating mode or temperature is selected.

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-20Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-21

How to set a Temporary Override

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-22
Setting a temporary override allows you to set a target temperature that will override your current heating program until your next heating period or for a set duration.

Energy Monitor

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-23

How Energy Monitor Works
The STRATA_HEAT™ Wi-Fi Thermostat learns how you use your system and how your house reacts to heating and weather. Using the MySTRATA_HEAT App, energy monitoring will show the amount of energy consumed over a certain time period. This will be calculated through system power multiplied by efficiency and run time. You will need to enter the power of your system, and in some cases, the efficiency. If you do not know these, speak to your installer or system manufacturer.

Geo Location Settings

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-24
How Geo Location Works
Geo is a unique technology developed by LATICRETE and built into the MySTRATA_HEAT App that uses an advanced algorithm to understand the most efficient heat settings for your home. Working automatically; it learns your routines and location through background communication with your smartphone and lowers temperatures when you are away, only rising them up to your ideal comfort temperature in time for your arrival home. Geo will operate when the thermostat is in the program or manual run modes. It is turned off by default. Use the MySTRATA_HEAT App to switch Geo on.

Settings

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-24Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-24Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-24

Troubleshooting

Display is blank Power (Electrician Required) Electrician required to verify power is going to the STRATA_HEAT™ W-iFi Thermostat and that it is correctly wired.
Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-24 Control

(5 & 6) / Internal Air sensor error

1. Please see Table 1.0 and ensure you have selected the correct thermostat application.

 

2. (Electrician Required) Electrician required to verify that the floor sensor has been wired correctly. If it is correctly wired the electrician will need to check the resistance of the floor sensor using a multi meter. For temperatures between 68°F – 86°F (20°C – 30°C) the resistance of the floor sensor should measure between 8K ohms and 12K ohms.

 

If the electrician finds a fault, and the thermostat is in the room to be heated then it can be set into “Air Mode”.

 

To set into “Air Mode”, see Table 1.0 Thermostat application.

 

If “– – –” still remains when set into air mode the thermostat will have to be replaced.

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-24 Limit Sensor Error (6 & 7)
Heating is coming on earlier than programmed times Adaptive learning (Early start) On Adaptive learning (Early start) will use the historic heating/cooling rates for the time of day, historic external temperatures and the forecast external temperatures, to work out the heating start time in order to reach the comfort time at the start of the comfort period. It will only work in Program Mode.
Wi-Fi Error Symbol

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-31

Wi-Fi not setup 1.  Download and open the MySTRATA_HEAT App

2.  Remove STRATA_HEAT W-iFi Thermostat from the wall

3.  Scan QR code on the back of the display

4.  Place thermostat back on the wall and power-up

5.  Thermostat will be in pairing mode for 1 minute. App should automatically connect to phone

6.  Follow instructions in App

Wi-Fi disconnected Follow the step above to try and to re-connect to the Wi-Fi Network.
If the thermostat still fails to connect, see Wi-Fi Troubleshooting.
Clock IconLaticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-31 Time and Date not set Connect the STRATA_HEAT™ W-iFi Thermostat to a Wi-Fi network or alternatively set the time and date from the settings menu.
GFCI Icon

GFCILaticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-31

GFCI test button The GFCI feature is used to detect any leakage of current from your heating system. During a ground fault the two lines of the load will be cut off. Once your thermostat is installed and connected to a power supply you can test the GFCI function by increasing the set temperature until heating is on – the heat up icon

( ) will be illuminated – and pressing the “TEST” button.

 

If your test is successful you will see the GFCI error icon and you will need to hold “X” for 3 seconds in order to restore heating operation.

Heater error The GFCI has tripped due to a fault in the heater.

 

(Electrician Required) Electrician required to verify that the heater has been wired correctly. If correctly wired please conduct a resistance test and insulation resistance test on the heater to see if damage has occurred.

Relay iconLaticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-31

 

Relay error The STRATA_HEAT W-iFi Thermostat has detected that one of the relays has FAILED.

 

Please contact LATICRETE

Wi-Fi Troubleshooting
Before following the troubleshooting guide below please check the following:

  1. The password is WPA2 protected.
  2. The router is set to a 2.4 GHz band. (802.11 b, g, n, b/g mixed, b/g/n mixed)

NOTE: If you need to change any of the items listed above, please refer to your router manual.

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-35

Technical Specifications

Model RSW-XX-YY-ZZ
Operating Voltage 110V – 240V AC +/–15% 50Hz/60Hz
Protection Class II
 

Max. Load

15A resistive (120 V – 1800W, 240 V – 3600W)
GFCI Class A GFCI with 5mA trip level
Rated impulse voltage 4000V
Automatic action 100,000
Disconnection means 1B
Pollution degree 2
Max. Ambient Temperature 40°C / 104°F (T40)
Relative Humidity 80%
IP Rating IP30
Sensors Floor/Air
Sensor Type NTC10K @ 25°C
Operating Frequency 2401 – 2484MHz
Max. Radio-Frequency Power Transmitted 20dBm
Compatibility Electric Floor Heating and Baseboard Heating
 

 

 

Standards

UL-60730-1 UL-60730-2-9 UL-943

CAN/CSA-E60730-1 CAN/CSA-E60730-2-9 CAN/CSA-C22.2 No. 144.1

FCC 47 CFR Part 15, ICES-003

Warranty 1 Year
Approvals ETL Intertek

Warranty

LATICRETE warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for 1 year from the date of purchase by the consumer. If at any time during the warranty period, the product is determined to be defective, LATICRETE shall repair or replace it, at LATICRETE’s option. If the product is defective, please either;

Laticrete-RSW-XX-YY-ZZ-Smart-WIFI-Thermostat-fig-35
Return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or Contact LATICRETE. LATICRETE will determine whether the product should be returned or replaced. The 1-year warranty only applies if the product is registered with LATICRETE within 30 days after purchase. Registration can be completed online at www.laticrete.com This warranty does not cover removal or re-installation costs and shall not apply if it is shown by LATICRETE that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation, or damage that occurred while the product was in the possession of a consumer. The sole responsibility of LATICRETE shall be to repair or replace the product within the terms stated above. This warranty does not extend to any associated software such as apps or portals.

LATICRETE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY LATICRETE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. This Warranty does not affect your statutory rights.

LATICRETE International, Inc. One LATICRETE Park North, Bethany, CT 06524-3423 USA 1.800.243.4788  +1.203.393.0010  www.laticrete.com
DS-10048-0122 ©2022 LATICRETE International, Inc. All trademarks shown are the intellectual properties of their respective owners.

REFERENCE:

DOWNLOAD MANUALS:

Laticrete RSW-XX-YY-ZZ Smart WIFI Thermostat Operating Manual

Laticrete-logo

Laticrete RSW-XX-YY-ZZ Smart WIFI Thermostat Operating Manual

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)