Specifications

  • Power Supply: 120VAC/208VAC/240VAC 50/60Hz
  • Max Range: 1800W@120V 3120W@208V or 3600W 240 V
  • Accuracy: +01F (01C)
  • Temperature Control Range: 41°F-95°F
  • Temperature Adjustment Scale: 1°F
  • Listing: c ETL us

WARNING:

READ CAREFULLY – These instructions will help prevent difficulties that might arise during thermostat installation. Studying the instructions first may save Considerable time and money later. Observing the following procedures will keep installation time to a minimum. Save these instructions for future use.

FUNCTIONS AND FEATURES

This Thermostat has been designed to control fan-forced and radiant line voltage electric heaters.King Electric-K302PE-Programmable-Thermostat-FIG.1

  • Dual Voltage (120vac or 240vac)
  • Blue Backlit Display
  • 7-day programmable settings
  • Temperature Lock Feature: Set a Min and Max Temp Limit
  • Touch-Sensitive Buttons
  • System On/Standby Switch

King Electric-K302PE-Programmable-Thermostat-FIG.2

PRODUCT OVERVIEW

The Clear Touch K302PE combines user-friendly touch-sensitive buttons with a sleek modern design, offering unparalleled user control. It’s highly accurate sensing technology saves up to 28% on heating costs. Energy-Saving Programmable Solution For Providing Highly Accurate Temperature Control For Line Voltage Electric Heaters. It is accurate and sensitive with high reliability and high performance. Program a full 7-day schedule with ease for total room control

INSTALLATION INSTRUCTIONS

The installation of the thermostat must comply with the applicable local and/or national electrical code and utility requirements. This installation should be performed by a qualified electrician where required by law. Ensure that all wiring connections to the thermostat are correct and tight to prevent electrical shorts. Use the appropriate wire to meet local and national electrical codes for rated power consumption.

ELECTRIC SHOCK OR FIRE HAZARD READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS, AND SAFETY DATA TO AVvoID PROPERTY DAMAGE AND PERSONAL INJURY.

WARNING!
Warning: Turn OFF the power at the circuit breaker before Installing. Installation to be performed by a qualified electrician or authorized technician. Refer to thermostat and heater load specifications before installation of the thermostat to see if it can handle the amp load. The maximum this thermostat can run is 1800W @120V or 3600 W @ 240 V (15A). Install unit in a grounded metal or plastic wall junction box, indoors 4 %’ to 5′ above the floor. Avoid any area whereit can come in contact with external sources of heat and cold. This includes plumbing pipes, direct sunlight, a T.V. set, lamps, and drafts from a door or window, as this may cause inaccurate temperature readings. The most convenient place is above the light switch. Not for Outdoor uSe.

WIRING INSTRUCTIONS

Caution: Turn off the power at the circuit breaker before performing any work on the electrical connections. None of the electrical connections must be live until the installation has been completed and the housing is closed. Only a qualified electrician or authorized technician are permitted to open the terminal box.

Wiring requires a Phillips screwdriver

King Electric-K302PE-Programmable-Thermostat-FIG.3

  1. Disconnect the power supply to prevent electrical shock or damage to the product.
  2. Run line voltage wiring to the location of the thermostat.
  3. Use a screwdriver to separate the Display Panel and power board of the thermostat, as shown in Figure 1 and Figure 2
  4. Choose the proper installation location. Installation height is about 412 to 5 feet above the floor. For indoor use only.
  5. Do not install close toa heat source, such as hot water pipe, heating pipe, wall-mounted light fixture or in direct sunlight.
  6. Connect the incoming power wires to Line 1() & Line 20) wires on the power board, using the provided wire nuts, as shown in Figure 3.
  7. Connect the heater load wires to the Load 1 & Load 2 wires of the power board, using the connectors, as shown in Figure 3.

(Optional) Connection to a Slave Relay (K312RELAY)

  1. If the heating area requires the addition of a Slave Relay, connect the low voltage wire for an auxiliary Slave Relay (K312RELAY) into terminal 5&6 (Relout) on back of the power board to add a zone. See the drawing beloOW.
  2. Install the power board into the electrical box with the 2 screws provided, and then clip & fasten the front Display Panel into place with the bottom screw.
  3. Make sure your K302PE thermostat is COMPLETELY RECESSED into the junction box and flush with the wall. NO WIRES SHOULD BE EXPOSED outside
  4. the metal or plastic junction box.

Safety Information:

WIRING DIAGRAM

King Electric-K302PE-Programmable-Thermostat-FIG.4

  • Installation must be carried out by a certified professional electrician.
  • Disconnect all power before performing maintenance work to avoid product damage.
  • Shocking, dropping, or stepping on the product will damage it and void the warranty.
  • The thermostat should be kept away from corrosive chemicals.
  • Damage to the product could result in a faulty electrical system that may cause a fire.

CONTROL DIAGRAM

King Electric-K302PE-Programmable-Thermostat-FIG.5

Control Wiring

  • Setback: This is an input signal driven by a remote contact. One terminal connects to the internal power source by 10K resistance; another terminal connects to the internal ground. The circuit diagram is shown on the left.
  • Relout: This is an output allowing the remote control of a series of Slave Re- lays (K312RELAY). Inside the thermostat is an open drain circuit, driving a 24V relay. The maximum drive current is 30 mA. The circuit diagram is shown in the left. This is used to connect to a Slave Relay (K312RELAY) to expand the heating Surface. Multiple Slave Relays can be interconnected in a daisy chain, see below

Master/ Slave Wiring Diagram

King Electric-K302PE-Programmable-Thermostat-FIG.6

OPERATION INSTRUCTIONS

King Electric-K302PE-Programmable-Thermostat-FIG.7

ON/OFF Settings

  • ON: From the OFF status, slide the ON/OFF side switch up to turn the unit ON. The display will show Time, Room Temperature, current Mode and Heating status.
  • OFF: From the ON status, slide the ON/OFF switch down to turn the unit OFF. The display will show OFF

Reset

  • With unit set to OFF, press reset button for 3 seconds to do a factory reset. The thermostat will reset to factory defaults. The factory default temperature unit is Fahrenheit and the default time system is the 12 Hour Clock.

Setting the Time

  • In the normal working interface, press King Electric-K302PE-Programmable-Thermostat-FIG.8the button for 3 seconds to enter into the Time setting interface.
  • First, “WEEK” is blinking, press King Electric-K302PE-Programmable-Thermostat-FIG.9the button to set the day of the week
  • When finished setting the DAY, pressKing Electric-K302PE-Programmable-Thermostat-FIG.10 the button to switch to HOUR, “HOUR” is blinking, press theKing Electric-K302PE-Programmable-Thermostat-FIG.9 button to set the hour.
  • When finished setting the HOUR, press the King Electric-K302PE-Programmable-Thermostat-FIG.10button to switch to MINUTES, “MINUTE” is blinking, so pressKing Electric-K302PE-Programmable-Thermostat-FIG.9 the button to set the minutes
  • When finished setting the MINUTES, press King Electric-K302PE-Programmable-Thermostat-FIG.10a button or wait 10 seconds to save the new values and return to the normal interface automatically.
  • In the setting interface, press King Electric-K302PE-Programmable-Thermostat-FIG.11the button at any time to return to the normal working interface. The new values will be saved.

Setting the Set Temperature

  • In any mode, press King Electric-K302PE-Programmable-Thermostat-FIG.9button to enter into the Set Temp settings interface of the corresponding mode. The Set Temp is blinking.
  • Press button to decrease the temperature, press button to increase the temperature set point.
  • After enter into the interface of Set Temp settings, press King Electric-K302PE-Programmable-Thermostat-FIG.9button for 3 sec. to decrease/ increase the temperature continuously.
  • Once completed, press King Electric-K302PE-Programmable-Thermostat-FIG.11the button to confim changes or walit for 10s without any operation to save the values and retun to the normal working interface automatically.

Keypad Lock

  • In the normal working interface, press King Electric-K302PE-Programmable-Thermostat-FIG.9buttons simultaneously to lock the keypad, at the same time the icon King Electric-K302PE-Programmable-Thermostat-FIG.12will display on the screen.
  • When the keypad is locked, no adjustment is possible. When the icon of the Keypad lockKing Electric-K302PE-Programmable-Thermostat-FIG.12 displays on the screen, pressKing Electric-K302PE-Programmable-Thermostat-FIG.9simultaneously to unlock the keypad, and the iconKing Electric-K302PE-Programmable-Thermostat-FIG.12 will disappear from the screen and the keypad is back to its normal state.

Setting the Time Periods (Schedule)

  • In the normal working interface, press King Electric-K302PE-Programmable-Thermostat-FIG.8the button to enter into the Time Period settings interface. First, the “HOUR” of the first period is blinking.
    • The blinking item is adjustable, press theKing Electric-K302PE-Programmable-Thermostat-FIG.9 button to change the value.
  • In the setting interface, pressKing Electric-K302PE-Programmable-Thermostat-FIG.8 the button to Switch the weekday, the sequence is Monday- Tuesday – Wednesday-Thursday- Friday- Saturday- Sunday – Exit.
  • In the setting interface, pressKing Electric-K302PE-Programmable-Thermostat-FIG.10 the button to switch the following parameters: HOUR, MINUTE, Set Temp, and Time Period of each day, press King Electric-K302PE-Programmable-Thermostat-FIG.10continuously, the time period will be switched from the 1st period to the 4h period.
  • In the setting interface, press King Electric-K302PE-Programmable-Thermostat-FIG.11button to return to the normal working interface directly, and the new values will be saved.

Setting the Control  Mode

  • PressKing Electric-K302PE-Programmable-Thermostat-FIG.10 button to enter the Control Mode settings interface. With each press of theKing Electric-K302PE-Programmable-Thermostat-FIG.10 button, the thermostat changes to the next Control mode.
  • When the King Electric-K302PE-Programmable-Thermostat-FIG.13icon is illuminated the thermostat is in Programmed Schedule Mode; the thermostat will follow the programmed heating schedule
  • Whenthe icon has illuminated the thermostat is in Permanent Hold Mode; this is a permanent override of programmed settings.
  • When theKing Electric-K302PE-Programmable-Thermostat-FIG.15 icon is illuminated the thermostat is in Energy-Saving Setback Mode; this is a permanent override setback temperature.
  • When the King Electric-K302PE-Programmable-Thermostat-FIG.16icon is illuminated the thermostat is in Vacation/Away Mode; this is a permanent override setback temperature.
  • Press the King Electric-K302PE-Programmable-Thermostat-FIG.11button or wait for 10 seconds to confirm the setting.

Seta Temporary Override of Scheduled Temperature

With theKing Electric-K302PE-Programmable-Thermostat-FIG.13 illuminated on display, PRESS  King Electric-K302PE-Programmable-Thermostat-FIG.9buttons to set a Temporary Override Temperature. This set temperature will remain until the start of pressing the next programmed period on the heating schedule.

Set a Permanent Hold Temperature

  • Press King Electric-K302PE-Programmable-Thermostat-FIG.10the button repeatedly until the icon is illuminated.
  • PressKing Electric-K302PE-Programmable-Thermostat-FIG.11 the button or wait for 10 seconds to confirm the setting.
  • PressKing Electric-K302PE-Programmable-Thermostat-FIG.9 buttons to set a Permanent Hold temperature. This is a permanent hold temperature until it is turned off.
  • To turn off and return to the Programmed Schedule Mode PressKing Electric-K302PE-Programmable-Thermostat-FIG.10 button repeatedly until the King Electric-K302PE-Programmable-Thermostat-FIG.13icon is illuminated.
  • Press the King Electric-K302PE-Programmable-Thermostat-FIG.11button or wait for 10 seconds to confirm the setting.

Switching to Energy Saving Setback Mode

  • PressKing Electric-K302PE-Programmable-Thermostat-FIG.10 the button repeatedly until the King Electric-K302PE-Programmable-Thermostat-FIG.15icon is illuminated.
  • Press the King Electric-K302PE-Programmable-Thermostat-FIG.11button or wait for 10 seconds to confirm the setting. This is a permanent override setback temperature.
    To change the Energy-Saving Setback temperature, press King Electric-K302PE-Programmable-Thermostat-FIG.9 change. Press theKing Electric-K302PE-Programmable-Thermostat-FIG.11 button or wait for 10 seconds to confirm the setting.
    Note: This will be saved as the new P6 setting under the Hidden Menu settings.
    To turn off and return to the Programmed Schedule Mode Press button King Electric-K302PE-Programmable-Thermostat-FIG.10repeatedly until the icon King Electric-K302PE-Programmable-Thermostat-FIG.13is illuminated.

Switching to _Vacation/Away Mode

  • PressKing Electric-K302PE-Programmable-Thermostat-FIG.10 the button repeatedly until the iconKing Electric-K302PE-Programmable-Thermostat-FIG.16 is illuminated.
  • Press theKing Electric-K302PE-Programmable-Thermostat-FIG.11 button or wait for 10 seconds to confirm the setting. This is a permanent override setback temperature.
  • To change the Vacation/Away Mode temperature, press King Electric-K302PE-Programmable-Thermostat-FIG.9 to change. Press the King Electric-K302PE-Programmable-Thermostat-FIG.11button or wait for 10 seconds to confirm the setting.
    Note: This will be saved as the new P7 setting under the Hidden Menu settings.
    To turn off and return to the Programmed Schedule Mode PressKing Electric-K302PE-Programmable-Thermostat-FIG.10 button repeatedly until the King Electric-K302PE-Programmable-Thermostat-FIG.13icon is illuminated.

The default values of time periods are as follows:

7 Days default values of time periods
time period 1 2 3 4
start time 5:00 7:00 5:00 10:00
set trmp ℃(    ℉) ℃(    ℉) ℃(   ℉) ℃(   ℉)

Note: The default start time of the second period of Saturday and Sunday is different from the default start time of Monday b Friday. The default start time of the second period of Saturday and Sunday is 9: 00, but the Set Temp is the same.

Output Control

Room Temperature Control Mode

When the icon King Electric-K302PE-Programmable-Thermostat-FIG.17displays on the screen it indicates the system is in Room Temperature Control Mode, when the icon King Electric-K302PE-Programmable-Thermostat-FIG.18displays on the screen, indicating the ambient temperature from the built-in probe. When the detected indoor temperature is below the set temperature by -2°C(-4°F), electrical heating will be turned on, and the icon King Electric-K302PE-Programmable-Thermostat-FIG.19Will display on the screen; When the detected indoor temperature is above the set temperature, electrical heating will be turned off, and the icon King Electric-K302PE-Programmable-Thermostat-FIG.19will disappear from the Screen.

Remote Control of Thermostat
When there is a remote control signal input, the Remote icon (bar) blinks; when the detected indoor temperature is below the set temperature by -2°C(-4F), electrical heating will be turned on, and the icon King Electric-K302PE-Programmable-Thermostat-FIG.19Will display on the screen; meanwhile, the Relout sends the output signals. When the detected door temperature is above the set temperature, electrical heating will be turned off, and the iconKing Electric-K302PE-Programmable-Thermostat-FIG.19 Will disappear, and the Relout turns off the power module output signal. The default set temperature is 16.5C (61F) in the remote control mode.

Note: Remote signal control signal has the highest priority in the logic sequence.

Sensor Failure
When the sensor fails to work, the error icon EEE will be displayed on the screen. The output relay will open. The heating output will stop. Replace sensor.

Cumulative Heating Time to compute the energy consumption

Press King Electric-K302PE-Programmable-Thermostat-FIG.11the button, and the cumulative heating time will be displayed on the screen. The cumulative time will reset and restart when pressing And King Electric-K302PE-Programmable-Thermostat-FIG.8Buttons simultaneously. (Unit: min)

Configuration of User Parameters (Hidden Menu)
When the thermostat is OFF: Press) and buttons simultaneously to enter into the setting interface. Default values and options are defined below:

King Electric-K302PE-Programmable-Thermostat-FIG.20

Troubleshooting

King Electric-K302PE-Programmable-Thermostat-FIG.21

KING ELECTRIC MFG CO 9131 10TH AVENUE SOUTH SEATTLE, WA 98108
PH:206 762 0400-
FAX: 206 763 7738

www.king-electric.com

REFERENCE:

DOWNLOAD MANUALS:

King Electric K302PE Programmable Thermostat Installational Instruction

King Electric-LOGO

King Electric K302PE Programmable Thermostat Installational Instruction

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *