Johnguest JGSTAT4W 240v Wired Programmable Room Thermostat
Specification
- Power source: 100-240VAC 50/60Hz
- Load current output: 250VAC 3(2)A
- Temperature setting range: 5~35°C
- Display accuracy: 0.1°C
- Setting accuracy: 0.5°C
- Storage temperature: -10~60°C, 0~90%RH
- Ambient temperature: 0~50°C, 0~80%RH
- Wireless frequency: Lora 868MHz
Important safety information
Read all of the information in this manual before installing this thermostat. removing, cleaning, or servicing this thermostat. Only a professional contractor should install this thermostat. All wiring must conform to local and national building and electrical codes and regulations. If the system is not operating properly, check the wiring and replace the fuse if necessary. Use this thermostat only as described in this manual.
Thermostat display
ON/OFF/Boost
Time setting
Menu button
Lower temperature setting
Raise temperature setting
- Reset
- If the
icon is not shown then WiFi is not connected
- If the signal is lost after connection the icon will flash
- Manual mode
- Programming mode
- Zone number – If flashing then the connection to the wiring centre has been lost
- Key lock
- Boiler on/off
- Frost protection
- Holiday mode
- Settings menu
- Mode: Room mode, floor mode, dual temperature mode
- Sleep mode
- Away mode
- AM/PM
- Back home mode
- Wake up
- Temperature setting/Boost display
- Weeks icon
- Room temperature/time display
ON/OFF function
Press ‘ ’ to turn the thermostat ON. Press and hold ‘
’ again to turn the thermostat OFF.
Key lock function
In the main display interface, press and hold at the same time to activate or cancel the key lock. When activated, no keys can be used. The thermostat will display ‘
’.
Boost function
Press ‘ ’ to switch the setting temperature or boost control. When the display shows ‘+0 ’, press
to select boost hour. The length of time the heating will be boosted is displayed. When the time elapses the screen returns to the temperature display. Press ‘
’ to cancel and go back to the temperature display setting.
Holiday mode
With the power on, press ‘ ’ to switch between manual mode, programming mode and holiday mode. After selected holiday mode ‘
’ will display and will run at 16°C. Press ‘
’ to cancel holiday mode. Boost function can be used during holiday period.
Open window function
If the room temperature drops 6°C in 4 minutes, the open window function will activate and display ‘ ’, then turn down all heating. When the room temperature increases by 2°C the thermostat will return to normal operation. Press any button to cancel the open window function while it is active.
Anti-seize function
If the thermostat has not been activated for over 1 week then to prevent the valve and pump from seizing, the thermostat will run the system for 5 minutes.
Frost protection
In frost protection mode, when the temperature drops below what has been selected, the thermostat will start the heating until the temperature has been raised by 3°C.
Intelligent function
The intelligent function adjusts the starting time for home heating according to the temperature measured within the building. It preheats your rooms to the temperature according to your schedule.
Time Proportional and Integral (TPI) display
intervals, adjusting firing duration with demand, to maintain set room temperatures. It can provide great cost savings.
Time setting
Press and hold ‘ ’ for 4 seconds, press ‘
’ to select year, month, day, time scale, time, press
to adjust setting, press ‘
’ to confirm. If there are no actions for 10 seconds, the thermostat will return to temperature display mode. Press ‘
’ to check time, year, month, day
Setting the date and time on initial start up
Plug in the power supply. Pressto set year, press ‘
’ to set month, day, time scale, time, press
to adjust the setting.
Program setting
Program setting: 4/6 period programming optional (factory default: 6 period). When thermostat is on, press and hold ‘ ’ to enter the programming mode. Press
to select the programming week (5+2, 5+1+1 or 7 individual day optional). Press ‘
’ to enter time setting mode. Press
to select time, press ‘
’ to enter temperature setting mode, Press
to select temperature. Press ‘
’ to save and exit. If no buttons are pushed for 10 seconds, the thermostat will exit program setting automatically.
Default programming (6 period programming)
(4 period programming
Operation mode
Programming mode (The factory default is programmable) The thermostat will run according to the pre-set schedule. The screen will show ‘ ’
Manual mode
From programming operation mode, press ‘ ’ to enter the manual mode, the screen will display ‘ ’. Press
to immediately adjust the temperature and save automatically.
Temporary hold mode
The thermostat will keep the room at the temporary set temperature, and will resume the programme operation mode when you enter the next programme. In programming operation mode, press to enter the temporary hold mode, the screen display ‘
’. Press
to immediately adjust the temperature and save automatically.
Alarm instructions
Pairing
- With the thermostat power off, press and hold the on/off button for 4 seconds to enter pairing mode (display should show “rF1 ”).
- Press the on/off button again to send a signal to the wiring centre (display should show “
”)
- On the Wiring Centre, press and hold the pairing button for 3 seconds to enter pairing mode
- Use the Wiring Centre pairing button to select the desired zone, indicated by the LED
- Leave the wiring centre for 3 seconds. The LED should flash to indicate it is pairing to the thermostat
- Once paired, the wiring centre LED will move to the next available zone.
- Press and hold the pairing button once again to exit the pairing mode
- The thermostat is now connected to the chosen zone
Installation
- Install the base
- Mounting screws
- Install the panel
- Finish
Wiring diagram
Configuration menu
With the thermostat turned off, press and hold ‘= ‘to enter the configuration menu. Press ‘=’ to select different parameters. Press to adjust parameters. Press and hold ‘
’ for 3 seconds, display ‘def ’, indicates all the configuration settings have reverted to factory default setting. The thermostat will return to ‘ ’ mode if no buttons are pushed within 10 seconds.
Gateway specification
- Adapter output: 5V — 1A
- Working temperature: -10°C~55°C
- Working humidity: 10%-90%(no condensation)
- Wifi frequency: 2.4G Wi-Fi
- Wireless frequency: Lora 868MHz
- Dimensions: 60.5 × 60.5 × 16.1mm
Connecting the App
Download and register
Click App store (click Android application market) Search for ‘JG Underfloor’ and download
Login
When you finish the registration, log into your email and click on the link to activate your account. Your APP is now ready to use.
Connecting to the Gateway
Tips: First, please turn on the location of your phone. Press and hold the reset key of gateway until the light turns red and blinks.
- Enter the ‘HOME’ interface of the app, click the ‘
’ on the top right.
- Click ‘Wireless thermostat’.
- Enter your Wi-Fi account and password. Click ‘Next’
- Tick ‘Confirm and proceed’,then click ‘Next’ (Follow intruction to reset device)
- Adding device
- Click ‘Done’, it means the gateway has been added successfully
ADD THERMOSTAT Before adding the thermostat, press and hold ‘ ’ for 3 seconds, press
’ to select ‘rF2 ’, then press ‘
’ to enter code match status and it will display ‘ ’ then then follow these steps to connect the app.
- Click ‘ Add subdevice’
- Adding device…
- Added successfully Click ‘Done’.
APP Setting-programming
APP Setting-Multi-day Programming
Optional Parameter Setting
Remove devices
Voice command
Amazon Alexa
- Alexa, turn on bedroom.
- Alexa, raise the bedroom by 1 degree.
- Alexa, drop the bedroom by 1 degree.
- Alexa, set the bedroom to 16 degrees.
Google Assistant
- Ok, Google, turn on bedroom.
- Ok, Google, turn oF bedroom.
- Ok, Google, set the bedroom to 16 degrees
Reliance Worldwide
- Corporation (UK) Limited
- Horton Road
- West Drayton
- UB7 8JL
- United Kingdom
- Tel: +44 (0) 1895 449233
- Reliance Worldwide Corporation
- (UK) Limited reserves the right to make changes to the product which may aBect the accuracy of information contained in this leaflet
- www.reliancevalves.com
Reference
Download Manual:
Johnguest JGSTAT4W 240v Wired Programmable Room Thermostat User Manual
Other Manual:
Johnguest JGSTAT4W 240v Wired Programmable Room Thermostat Product Specification Guide
Johnguest JGSTAT4W 240v Wired Programmable Room Thermostat User Manual
Leave a Reply