Hunter- 44378- 7-Day -Programmable- Thermostat- fea

Hunter 44378 7-Day Programmable Thermostat Installation Sheet

Hunter-logo

Hunter 44378 7-Day Programmable Thermostat  

Hunter- 44378- 7-Day -Programmable- Thermostat- pro

Preparation

Gathering Tools and Warnings 

This thermostat is compatible with most conventional oil, gas, electric, hot water systems, single stage, and multi-stage heat pumps. This thermostat will not control line voltage systems. You will need the following tools to complete your installation:

  • Phillips Screwdriver (#2)
  • Two 1.5V (AA) size alkaline batteries
  • Take note of these warnings and cautions before proceeding:
  • Read all installation instructions before beginning installation!
  • If you still need assistance after reading this manual, call our Technical Support at 1-888-880-3267.
  • Do not disconnect the wires from your old thermostat until all wires have been properly labeled. You must label all wires properly because wire color may not indicate the function of the wire.
  • All wiring must be done in accordance with local code and ordinances.
  • Always turn power off to your furnace/compressor before the installation process. Failure to do so could result in damage to your thermostat and/or your heating and cooling system. Do not restore power until your installation is complete.
  • This thermostat is designed for use with 24V AC/ millivolt systems with a maximum of 1 amp. Higher amp or line voltage systems will cause damage to your system and increase the risk of fire.

Old Thermostat RemovalHunter -44378- 7-Day -Programmable -Thermostat- fig (1)

  • Turn off power to your compressor and furnace.
  • Remove the cover to your existing thermostat. Some thermostats may have screws or other locking devices that must first be removed. Once the wall plate is exposed, locate the wire terminals and try to identily the wire designations. If the wire terminals are not visible, they may be connected to the back of the wall plate. Look tor any additional screws, tabs, or locking devices to remove the wall plate. See Figure 1. It you are still unable to find the terminals for the wires, it may be necessary to contact the manufacturer of the original thermostat.Hunter -44378- 7-Day -Programmable -Thermostat- fig (2)

Labeling Your Wires
Use the table in Figure 2. to write down your wire colors and the letter designations on the old thermostat. This will allow you to keep a record of your old thermostat’s wiring configuration should you need to refer to it at a later time. This will also help our Technical Support Department determine your system type and proper wiring, should you need to contact them. Wire color does not indicate the function of the wire, this is being used only to help determine which wire has what letter designation.

Wire Color Wire Letter

ConventionalHunter -44378- 7-Day -Programmable -Thermostat- fig (3)

  • After writing down the wire colors and letters, use the terminal stickers to label the wires. Figures 3a and 3b will help you depending on system type; Conventional or Heat Pump.
  • Not all terminals will be used, this will be determined by your system type.
  • To ensure wires do not fall back into the wall hole, you may tape them to the wall, or wrap them around a pencil. Figure 4. may assist you if your old thermostat is a heat pump from one of the listed Manufacturers and your wire labels do not match. It is located on the back of this sheet

Heat Pumps

Hunter -44378- 7-Day -Programmable -Thermostat- fig (4)

These tips will also help you in wiring:

  • Only 1 reversing valve is needed to run a heat pump. If both “O” and “B” are present, “B” may be a common wire.
  • Often, 2-wire heat only systems do not have terminal labels. Connect 1 wire to the Rh terminal and the other to W.
  • If you have a 3-wire hot water system, the damper valve control wire will be labeled and attached to the “A” terminal.
  • If you need further assistance with wiring, or determining your system type, you can contact our Technical Support Department. See the “Technical Support” section for information.

Installation

Mounting the Wall Plate 

  • Remove the wall plate by pulling it straight off the back of the Thermostat. Figure 5.
  • Pull the wires through the back of the mounting plate, ensuring none of the wire labels are removed. Figure 6.Hunter -44378- 7-Day -Programmable -Thermostat- fig (6)

Using a Phillips Screwdriver, Partially install 1 screw into the top hole of the thermostat. Ensure the thermostat is level using the bubble level on the wall plate, Figure 7, then install the other screw. Tighten both screws until secure. Figure 8.Hunter -44378- 7-Day -Programmable -Thermostat- fig (7)

  • Check the charts on the back of this sheet and identify your system type. They are divided by Conventional and Heat Pump installations.
  • Raise all of the levers on the terminals you will be using. Heat Pump Installation labels are located on the left of the terminal blocks on the mounting plate and
  • Conventional labels are on the right. If your installation does not call for the jumper, remove it now. It is located underneath the wire holes, between the RH and RC terminals on the conventional side. Figure 9.
  • If one of the terminals you need has a tab in front of it, use your finger to break the ab awayHunter -44378- 7-Day -Programmable -Thermostat- fig (8)
    • Insert the bare end of each wire all the way into the appropriate hole in the terminal block that matches the wire label then lower the lever. This will lock each of the wires in place. Tuck excess wire back into wall after they have been locked in the mounting plate.
    • Before mounting the thermostat onto the mounting plate, turn it over and find the 2 switches located on the circuit board next to the battery compartment.
    • Set the system switch to “Cnv” if you have a conventional HVAC system or “H.P.” if you have a heat pump system. Set the furnace type to “Elc” if you have an electric convention system or a heat pump. “Gas/Oil” will be used if you have gas or oil-based conventional system. Figure 10Hunter -44378- 7-Day -Programmable -Thermostat- fig (9)
  • Lay the ribbon across the battery compartment and install 2 (AA) Batteries into the back of the thermostat over it, Figure 10., and snap the thermostat on to the mounting plate. Refer to “Setup” on page 10 of your owner’s manual to continue setup, scheduling, and daily useHunter -44378- 7-Day -Programmable -Thermostat- fig (10)

 

Technical Support

If you have any additional questions or problems with your Hunter thermostat, please call:

  • USA: 1-888-880-3267

We open 24 hours a day, 7 days a week. You may also contact us over the Internet at www.HunterHomeComfort.com.

Hunter Carrier Coleman Comfortmaker Bryant, Payne Rheem Ruud Trane, Weathertron York Lennox (1) Lennox (2)
R R R R R R R R R V-VR
Y Y or Y1 Y Y Y Y Y Y Y M
E W2 W2 W1 W2 W2 W W W1 Y
E E Jumper to W2 E E X2 Jumper to W2 E E
O O O O O O O R
B B B
G G G G G G G G G F
L L or F L L or X L L X L

CONVENTIONALHunter -44378- 7-Day -Programmable -Thermostat- fig (11)

HEAT PUMP

Hunter -44378- 7-Day -Programmable -Thermostat- fig (12)

Hunter -44378- 7-Day -Programmable -Thermostat- fig (13)

REFERENCE

DOWNLOAD MANUALS:

Hunter 44378 7-Day Programmable Thermostat Installation Sheet

OTHER  MANUALS:

Hunter 44378 7-Day Programmable Thermostat Owner’s Manual

Hunter-logo

Hunter 44378 7-Day Programmable Thermostat Installation Sheet


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)