General

HTW-61-CH06 heating thermostat is powered by 2*AA batteries, working as below logic:

  • the room temperature is lower than the setting, the output turns on
  • the room temperature is higher than the setting, the output turns off

Features

  • Display and set the room temperature
  • Six daily programmable time settings, Mondays to Sundays
  • Two work mode switchovers: (programmable, non-programmable )
  • Display temperature offset
  • Anti-freezing protection (OPTION)
  • Memory function: parameters are permanently held in memory and retained during power outages. (OPTION)

Specification

  • Temperature setting range (5-35℃), factory default:22℃
  • Room temp differential: -6℃~6℃adjustable (factory setting-2℃)
  • Temperature sensor: NTC
  • Temperature accuracy: +/-1℃
  • Power supply: 2AA batteries

Display and Buttons

hotowell-HTW-61-CH06-Heating-Thermostat-FEATURED

Operation

hotowell-HTW-61-CH06-Heating-Thermostat-FEATURED

  1. Press “F” can adjust the time. Press the “hotowell-HTW-61-CH06-Heating-Thermostat-FEATURED ” or “ hotowell-HTW-61-CH06-Heating-Thermostat-FIG-4” button to adjust the value of time and day.
  2. Both press “M” and “ hotowell-HTW-61-CH06-Heating-Thermostat-FIG-4” for 3s to lock or unlock the button. If locked, LOC will display.
  3. Programmable setting: Press “F” for 3 seconds to set the actual time and events per day, and press the “hotowell-HTW-61-CH06-Heating-Thermostat-FEATURED ” or “ hotowell-HTW-61-CH06-Heating-Thermostat-FIG-4” button to adjust the value of time and temperature. The periods and temperatures can be changed according to requirements. The time schedule default is set as below:
 

 

Week

Time    schedule
1 2 3 4 5 6
Time /℃ Time /℃ Time /℃ Time /℃ Time /℃ Time /℃
Mon. 6:00 / 20 7:30 / 15 11:30 / 20 14:00 /15 17:00 /20 22:00 /15
Tue. 6:00 / 20 7:30 / 15 11:30 / 20 14:00 /15 17:00 /20 22:00 /15
Wed. 6:00 / 20 7:30 / 15 11:30 / 20 14:00 /15 17:00 /20 22:00 /15
Thu. 6:00 / 20 7:30 / 15 11:30 / 20 14:00 /15 17:00 /20 22:00 /15
Fri. 6:00 / 20 7:30 / 15 11:30 / 20 14:00 /15 17:00 /20 22:00 /15
Sat. 6:00 / 20 7:30 / 15 11:30 / 20 14:00 /15 17:00 /20 22:00 /15
Sun. 6:00 / 20 7:30 / 15 11:30 / 20 14:00 /15 17:00 /20 22:00 /15

Note: when the set temperature is lower than 1℃, the set temperature display “OF” and in the period the output is off.

Installer Set-Up Process(ISU)

  1. Reset: under the power off state, press the “M” and “ hotowell-HTW-61-CH06-Heating-Thermostat-FEATURED” buttons together for 3s to return to the factory setting. It will display “rE” and press “ hotowell-HTW-61-CH06-Heating-Thermostat-FIG-4” to confirm.
  2. Under power, off, press the “M” button for 6s to enter the advanced setting, Press “M” can select and confirm the operation. Press “hotowell-HTW-61-CH06-Heating-Thermostat-FEATURED ” or “hotowell-HTW-61-CH06-Heating-Thermostat-FIG-4 ” to set the value.
 

Code

 

Function

 

Display

Factory setting
01 Model Setting 1—internal                sensor; 2—internal & external sensor 1-internal sensor
02 Temperature Calibration -8℃~ 8℃ 0℃
03 Upper Internal Sensor Switch Differential 0℃~ 6℃ 0℃
04 Lower Internal Sensor Switch Differential -6℃~ 0℃ -2℃
05 Anti-Freezing Protection ON/OF OF

Installation

hotowell-HTW-61-CH06-Heating-Thermostat-FIG-6

hotowell-HTW-61-CH06-Heating-Thermostat-FIG-7

  1. Open the backside plastic cover
  2. Unscrew the two screws
  3. Connect the wires from the boiler to NO and COM terminals
  4. Screw closely
  5. Cover the plastic

REFERENCE: