Honeywell TH5220D Non-Programmable Digital Thermostat 

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat

Product Application

This thermostat provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems, or 750 mV heating systems.

System Types
(up to 2 heat/2 cool)

Power Options 

Changeover Options 
Selectable manual or auto-changeover modes

System Settings
Heat, Off, Cool,Auto, Em Heat

Fan Settings
Auto, On

Must be installed by a trained, experienced technician

CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Installation tips

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-1

Do not install in locations where the thermostat can be affected by:

Pre-installation checklist

Package contents
Check to make sure your package includes the following items:

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-2

Required tools & supplies 

Wallplate installation Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-3

Remove the wallplate from the ther- mostat as shown at left, then follow directions below for mounting.

  1. Pull wires through wire hole.
  2. Position wallplate on wall, level and mark hole positions with pencil.
  3. Drill holes at marked positions as shown below, then tap in supplied wall anchors.
  4. Place wallplate over anchors, insert and tighten mounting screws. Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-4

Wiring

CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before wiring.Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-5

NOTES

R & Rc terminals
In single-transformer system, leave metal jumper in place between R & Rc. Remove metal jumper if two-transformer system.

C terminal
The C (common wire) terminal is optional when thermostat is powered by batteries.

W (O/B) terminal
If thermostat is configured for a heat pump in the Installer Setup, configure changeover valve for cool (“O” factory setting) or heat
(“B”).

L terminal (Output)
Heat pump reset. L terminal powered continuously when thermostat is set to Em Heat. Configure thermostat for 2 heat / 1 cool heat pump in the Installer Setup.

Wire specifications
Use 18- to 22-gauge thermostat wire. Shielded cable is not required.

Wiring

  1. Loosen screw terminals, insert wires into terminal block, then re-tighten screws.
  2. Push excess wire back into the wall opening. Keep wires in shaded area as shown at left.
  3. Plug the wall opening with non- flammable insulation to prevent drafts from affecting thermostat operation.

Terminal Designations

Conventional Terminal Letters:

Heat Pump Terminal Letters:

Wiring diagrams

  1. Power supply. Provide disconnect means and overload protection as required.
  2. Factory-installed jumper. Remove for 2-transformer systems only.
  3. Optional 24VAC common connection.
  4. In Installer Setup, set system type to Heat Only.
  5. In Installer Setup, set system type to 1Heat/1Cool Heat Pump & changeover valve to 0 or B. In Installer Setup, set system type to 2Heat/1Cool Heat Pump.
  6. L terminal is powered continuously when thermostat is set to Em Heat.
  7. Install field jumper between Aux and E if there is no emergency heat relay.
  8. In Installer Setup, set system type to 2Heat/2Cool conventional.Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-6Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-7Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-8Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-9 Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-10

Power options & mounting

AC Power
The thermostat can be powered by 24 VAC power, or by batteries.
To wire the thermostat for AC power, connect the common side of the cool- ing transformer to the “C” terminal as shown at left.
Important: Remove R/Rc jumper for 2-transformer systems only. (See wiring diagram on page 5.)

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-11

Battery Power
The thermostat can be powered by batteries alone or, if used with AC power, can provide backup power to the display during power interruptions.
After installation, batteries can be changed without removing the ther- mostat from the wall (see page 15).

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-12To Mount Thermostat
Align the 4 tabs on the wallplate with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place.

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-13

Installer setup

Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired.

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-14

Setup Function         Settings & Options

System type 

Changeover valve (O/B terminal)

Fan control (heating)

Heat cycle rate (CPH: cycles/hour)

Second-stage heat cycle rate/Auxiliary heat (CPH)

Emergency heat cycle rate (CPH)

Compressor cycle rate (CPH) 

Second stage compressor cycle rate (CPH) 

System setting adjustment

Temperature display 

Compressor protection

Auxiliary heat control 

Heat temperature range stops

28 Cool temperature range stops

Installer system test

Follow the procedure below to test the heating, cooling and fan.

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-16

System Test SystemStatus

Heating system

Emergency heating system

Cooling system

Fan system

Thermostat information (for reference only)

CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection (minimum off time) is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

Auto changeover (Setup Function 12)

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-17

Auto Changeover is a feature used in climates where both air conditioning and heating are used on the same day. When the system is set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 3 degrees apart. The thermostat will automatically adjust settings to maintain this 3-degree separation (called “deadband”).
The 3-degree separation between heating and cooling set temperatures is fixed, and cannot be changed.

Built-in compressor protection (Setup Function 15)

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-18

This feature helps prevent damage to the compressor in your air conditioning or heat pump system.
Damage can occur if the compressor is re-started too soon after shutdown.This feature forces the compressor to wait for a few minutes before restarting.
During the wait time, the message Cool On or Heat On (heat pumps only) will flash on the display.When the safe wait time has elapsed, the message stops flashing and the compressor turns on.

Auxiliary heat control (Setup Function 26)  

Systems with heat pumps can be set to operate in one of two ways: Comfort Setting: The thermostat will prioritize comfort over economy depending on heat pump performance, load conditions and whether the equipment is calling for heat. Raising the temperature just a few degrees will often activate auxiliary heat.

Economy Setting:
The thermostat will attempt to reach the temperature set- ting without activating auxiliary heat. The thermostat waits a preset time before allowing auxiliary heat to be activated depending on the compressor stage performance, and on how many degrees the temperature setpoint is changed.

Quick reference to controls Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-19

Quick reference to display screenHoneywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-20

Battery replacementHoneywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-21

In case of difficulty 

If you have difficulty with your thermostat, please try the suggestions below. Most problems can be corrected quickly and easily.

Display is blank

Temperature settings do not change
Make sure heating and cooling temperatures are set to acceptable ranges:

Heating system does not respond (“Heat On” appears on screen) 

Cooling system does not respond (“Cool On” appears on screen) 

Fan does not turn on in a call for heat
Check Installer Setup, Function 3 (Fan Control), to make sure the fan control is properly set to match the type of system (see page 11).

Heat pump issues cool air in heat mode, or warm air in cool mode
Check Installer Setup, Function 2 (Changeover Valve), to make sure it is properly configured for your system (see page 11).

Heat/cool both on at the same time, or heat does not turn off 

Heating equipment is running in cool mode

Cannot change system setting to “Heat”

Cannot change system setting to “Cool”

“Heat On” is not displayed
Change the System Setting to Heat, and set the temperature level above the current room temperature

“Cool On” is not displayed
Change the System Setting to Cool, and set the temperature level below the current room temperature.

“Cool On” or “Heat On” is flashing 
Compressor protection timeout is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.

Accessories & replacement parts

Please contact your distributor to order replacement parts.
Battery holder ………………………………………………Part Number 50007072-001
Coverplateassembly ………………………………….Part Number50002883-001 (Use to cover marks left by old thermostats.)

Specifications

Electrical Ratings

Honeywell-TH5220D-Non-Programmable-Digital-Thermostat-fig-22

Automation and Control Solutions

Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422
Honeywell Limited-Honeywell Limitée 35 Dynamic Drive
Scarborough, Ontario M1V 4Z9
www.honeywell.com/yourhome

Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.
® U.S. Registered Trademark.
© 2005 Honeywell International Inc. Patents pending. All rights reserved. 69-1783 02-2005

Reference

Download manual: Honeywell TH5220D Non-Programmable Digital Thermostat Installation Guide

Honeywell

Honeywell TH5220D Non-Programmable Digital Thermostat Installation Guide

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)