HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-featured

HONEYWELL T2 Pro THECC11060MX Programmable Thermostat Installation Instructions

Honeywell-logo

HONEYWELL T2 Pro THECC11060MX Programmable Thermostat 

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-13

Installation Instructions
Read before installing the unit

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-1

Package Includes:

  • T2 Pro Thermostat
  • Wall Plate Mounting System
  • Terminal Block (12 to 14 AWG)
  • Screws
  • Installation Instructions and User Guide

Wiring terminal designation

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-2

Power Supply: 120V~ @ 60 Hz, 13A

Terminal Designation
L Line
2 Pump
1 Low
C High

Selecting Location

Install the thermostat about 5 ft. (1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the thermostat where it can be affected by:

  • Drafts or dead spots behind doors and in corners.
  • Hot or cold air from ducts.
  • Radiant heat from sun or appliances.
  • Concealed pipes and chimneys.
  • Unheated (uncooled) areas such as an outside wall behind the thermostat.

Terminal block assembly

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-3

The terminal block is inserted in the wall plate at the factory. DO NOT remove the terminal block from the wall plate. If the terminal block is accidentally removed from the wall plate, please follow the next steps. Insert the terminal block into the wall plate slot from the front side until it clicks. Be sure that terminal block screws are on the back side of the wall plate and wire inputs are facing up at the end of the assembly.

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-4

Wall plate mounting system installation
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

  1. Before starting, turn the power off at the breaker box switch. Use the wall plate with the terminal block previously assembled. See “Terminal block assembly” on page 2.
  2. Identify the 4 wires inside the gang box (Line, Pump, High, and Low).
  3. Insert wires into the terminal block inputs and tighten screws using a screwdriver (wire color doesn’t indicate terminal designation). See “Terminal block
    assembly” on page 2.HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-5
  4. Place the wall plate over the gang box holes and be sure the arrow is pointing UP. Insert and tighten the mounting screws supplied in the box. Do not over-tighten. Tighten until the wall plate no longer moves.HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-6

Thermostat mounting

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-7

  1. Push excess wire back into the wall opening.
  2. Align the wall plate with the thermostat, and push gently until the thermostat snaps in place.
  3. Turn the power on at the breaker box or switch.

Set the time and dayHONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-8

  1. Press HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-9or HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-10 choose between 12 or 24 hours. Press Select.
  2. Use HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-9or HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-10adjust the Hour. Press Select.
  3. Use HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-9or HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-10 adjust the Minutes. Press Select.
  4. Use HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-9or HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-10choose the Day. Press Select to save and exit the Time menu.

System test

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-11

  1. Wait 5 minutes to allow the thermostat to sense the room temperature correctly (after this time a change in the temp displayed could occur).
  2. Press the Mode button until “Manual” flashes on the left side. Press Select.
  3. “Pump Only” flashes on the right side. Press Select and verify that the water pump is working.
  4. Press the Fan button to go to High Cool mode and verify that the water pump and motor’s high speed are working.
  5. Press the Fan button to go to Low Cool mode and verify that the water pump and motor’s low speed are working.
  6. Press the Fan button to go to High Vent mode and verify that the motor’s high speed is working and the water pump is OFF.
  7. Press the Fan button to go to Low Vent mode and verify that the motor’s low speed is working and the water pump is OFF.
  8. Press the Mode button 4 times until OFF is flashing on the left side, then press Select. If the unit is not working correctly, verify there are no loose connections or wires in the wrong terminal of the block.

Installer setup (ISU)

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-12

  1. Press and hold the CENTER and buttons HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-9for approximately 3 seconds to enter the advanced menu.
  2. Press Select to enter ISU.
  3. Press Select to cycle through menu setup options.
  4. Press HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-9or HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-10to change values or select from available options.
  5. Press Select and confirm your settings or press Back to ignore changes and return to the ISU menu screen to continue editing another setup option.
  6. To finish the setup process and save your setting, press Home and return to the Home screen.
    NOTE: A list of setup (ISU) parameters and options is on the next page.

Advanced set-up options (ISU)

#ISU ISU Name ISU options (factory default in bold)
120 Scheduling Options [0] = No schedule

[1] = All days same

[2] = |MO-FR|SA-SU|

[3] = |MO-FR|SA|SU|

[4] = Individual days (7 Days Programmable)

125 Temperature Indication Scale [0] = Fahrenheit

[1] = Celsius

430 Minimum Cool Setpoint 59 to 68 °F

15.0 to 20.0 °C

431 Maximum Cool Setpoint 86 to 95 °F

30.0 to 35.0 °C

1400 Continuous Backlight [0] = On Demand

[1] = Continuous

1401 (only if

ISU 1400 is

set to 1)

Inactive Backlight Level [0] = Off

1 to 5 levels

1410 Clock Format 12 hour, 24 hour
1420 Indoor Temperature Display Offset -3 to +3° in 1 °F increments

-1.5 to +1.5° in 0.5 °C increments

Default 0°

Note: The thermostat will follow an auto-calibration process the first time Low Cool runs for 3 consecutive hours and High Cool runs for 3 consecutive hours during normal operation. Low Cool and High Cool could run at different days or with an OFF period between. If booth speeds run consecutively Low Cool must be first.
Note: If the swamp cooler system is replaced it is highly recommended to reset the thermostat to factory default values to perform a new auto-calibration the process as follows:

  1. Press and hold the CENTER and buttons for approximately 3 seconds to enter the advanced menu.
  2. Press 2 times to go to the Reset Defaults option, and press select.
  3. Allow the thermostat to run the auto-calibration process as previously indicated.

Specifications

Temperature Ranges
59 °F to 95 °F (15 °C to 35 °C)

Working Ambient Temperature
32 °F to 120 °F (0 °C to 48.9 °C)

Shipping Temperature
-20 °F to 120 °F (-28.9 °C to 48.9 °C)

Operating Relative Humidity
5% to 90% (non-condensing)

Physical Dimensions in inches (mm) (H x W x D)
4-3/4” H x 4-3/4” W x 1-13/32” D
(121.2 mm H x 121.2 mm W x 35.8 mm D)

Motor Electrical Ratings
120V~ @ 60 Hz, 13A Max

Compatibility

Motor Power Rating NEMA Codes
1 HP (746 W) A, B, C, D, E, F, G
3/4 HP (560 W) A, B, C, D, E, F, G, H, J
1/2 HP (373 W) A, B, C, D, E, F, G, H, J, K, L, M, N
1/3 HP (249 W) A, B, C, D, E, F, G, H, J, K, L, M, N, P, R, S

WEEE Directive 2012/19/EU Waste Electrical and Electronic Equipment Directive
At the end of the product, life disposes of the packaging and product in a corresponding recycling center. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.

Customer Assistance

HONEYWELL-T2-Pro-THECC11060MX-Programmable-Thermostat-fig-13
For assistance with this product, please call
Resideo Honeywell Home Customer Care toll-free at
Mexico: 01-800-083-5925
Brazil: 0-800-047-4323
Colombia: 01-800-944-3620

Pull to remove the thermostat from the wallplate
Resideo Inc., 1985 Douglas Drive North
Golden Valley, MN 55422
33-00404ES—07 M.S. Rev. 09-19
Printed in the United States
This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN ©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.

Home Technologies
Instromet Mexicana S. de R.L. de C.V.
Avenida Insurgentes 2453, Piso 6,
Tizapan, Alvaro Obregon,
Ciudad de Mexico, CP 01090

REFERENCE:

Download Manual:

HONEYWELL T2 Pro THECC11060MX Programmable Thermostat Installation Instructions

Honeywell-logo

HONEYWELL T2 Pro THECC11060MX Programmable Thermostat Installation Instructions

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *