Honeywell PRO 2000 VERTICAL PROGRAMMABLE THERMOSTAT Installation Guide

Honeywel-Home-LOGO

Honeywell PRO 2000 VERTICAL PROGRAMMABLE THERMOSTAT 

Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-product

This manual covers the following models

  • TH1100DV: For Heat only systems
  • TH2110DV/TH1110DV: For 1 Heat/1 Cool systems
  • TH2210DV/TH1210DV: For 2 Heat/1 Cool heat pump systems only (Pull thermostat from wallplate and turn over to find a model number.)

System Types

TH2110DV/TH1110DV

  • Gas, oil, or electric heat with air conditioning
  • Warm air, hot water, high-efficiency furnaces, 1 Heat/1 Cool heat pump, steam, gravity
  •  Heat only
  •  Heat only with a fan
  •  Cool only
  •  750 mV heating systems

TH2210DV/TH1210DV

  • 2 Heat/1 Cool heat pumps TH1100DV:
  •  Gas, oil, or electric heat
  •  Warm air, hot water, steam, gravity
  •  Heat only
  •  750 mV heating systems

Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

Wallplate installation

Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-1

Remove the wallplate from the thermostat as shown on the left, then follow the directions below for mounting.

  1. Pull wires through the wire hole.
  2.  Position the wallplate on the wall, level, and mark hole positions with a pencil.
  3.  Drill holes at marked positions as shown below, then tap in supplied wall anchors.
  4.  Place the wallplate over the anchors, and insert and tighten the mounting screws.Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-2

CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation. Drill 3/16″ holes for drywall. Drill 7/32″ holes for plaster.

MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact the Thermostat Recycling Corporation at www.thermostatrecycle.org or 800-238-8192 for information on how and where to properly and safely dispose of your old thermostat.

Power options

Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-3

Note: Terminals vary by model

Wiring

Terminal designations

  • B Changeover valve energized in heating
  • O Changeover valve energized in cooling
  • G Fan relay
  • Y Compressor contactor
  • W Heat relay
  • C 24 Vac common. For 2-transformer systems, use common wire from the cooling transformer.
  • R 24 Vac power from the heating transformer
  • Rc 24 Vac power from the cooling transformer

TH2210DV/TH1210DV

  • B Changeover valve energized in heating
  • O Changeover valve energized in cooling
  • G Fan relay
  • Y Compressor contactor
  • Aux/E Auxiliary heat relay
  • C 24 Vac common
  • R 24 Vac powerHoneywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-4

TH1100DV

  • W Heat relay
  • C 24 Vac common
  • R 24 Vac powerHoneywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-5

TH2210DV/TH1210DV

  • B Changeover valve energized in heating
  • O Changeover valve energized in cooling
  • G Fan relay
  • Y Compressor contactor
  • Aux/E Auxiliary heat relay
  • C 24 Vac common
  • R 24 Vac power

Wiring guide — conventional and heat pump systems

Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-7Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-8

NOTES
Wire specifications:
Use 18- to 22-gauge thermostat wire. A shielded cable is not required.

  1. Power supply. Provide disconnect means and overload protection as required.
  2. Remove jumper for 2-transformer systems.
  3. Optional 24 Vac common connection
  4. The common connection must come from the cooling transformer.
  5. Use either O or B terminals for the changeover valve.
  6. Use a small piece of wire (not supplied) to connect W and Y terminals.
  7. Set the fan operation switch to Heat Pump (see page 5).

Fan operation settings

Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-9

TH2110DV/TH1110DV only:

  • Gas or Oil: For gas or oil heating systems, leave the fan operation switch in this factory-set position. (This setting is for systems that control the fan in a call for heat.)
  • Electric or Heat Pump: Change the switch to this setting for heat pumps or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat if a fan wire is connected to the G terminal.)

Thermostat mounting

Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-10

Installer setup

Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired. Function number
Setting To begin, press and hold the Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-12 AND Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-13buttons until the display changes.

Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-11

  • Press the Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-12 or Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-13 button to change the setting.
  • Press the Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-12 buttons Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-13simultaneously for one second to advance to the next function.
  • Press Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-12and hold the Honeywell-PRO-2000-VERTICAL-PROGRAMMABLE-THERMOSTAT-Installation-Guide-fig-13and t buttons to exit and save settings.

NOTE: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat automatically saves any changes made and exits the menu.

Installer setup

CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.
NOTE: The options below may not be available in all models.

Setup function Settings & options (factory default in bold)
5 Heating cycle rate (CPH: cycles/hour)

(TH2110DV, TH1110DV and TH1100DV)

5      For gas or oil furnaces of less than 90% efficiency

1      For steam or gravity systems

3      For hot water systems & furnaces of over 90% efficiency

6      For electric furnaces

[Other cycle rate options: 2 or 4 CPH]

6 Auxiliary heat cycle rate (CPH)

(TH2210DV and TH1210DV)

3      For hot water systems & furnaces of over 90% efficiency

1      For steam or gravity systems

5         For gas or oil furnaces of less than 90% efficiency

6         For electric furnaces

[Other cycle rate options: 2 or 4 CPH]

9 Compressor cycle rate (CPH) (TH2110DV, TH2210DV, TH1110DV, TH1210DV) 3      Recommended for most compressors

[Other cycle rate options: 1, 2, 4, 5, or 6 CPH]

13 Early Start (TH2110DV and TH2210DV) 1      On **See page 8

0      Off

14 Temperature display 0         Fahrenheit

1         Celsius

15 Compressor protection (TH2110DV, TH2210DV, TH1110DV, TH1210DV) 1      Five-minute compressor off time (See page 8)

0      No compressor off time

20 Clock display (TH2110DV and TH2210DV) 0         12-hour display

1         24-hour display

25 Lower temperature range (TH1100DV only) 0         Standard range 40°F to 90°F (4.5°C to 32°C)

1         Lower range (for garage mode) 35°F to 90°F (1.5°C to 32°C)

40 Restore program schedule to default

(TH2110DV and TH2210DV)

0         Off

1 On-program schedule default settings are listed in the operating manual

CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage,
avoid cycling the compressor quickly.

NOTE: The options below may not be available in all models.

CAUTION: ELECTRONIC WASTE NOTICE
The product and batteries should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health. FCC statement at: https://customer.resideo.com/en-US/support/residential/ codes-and standards/FCC15105/Pages/default.aspx

Special functions

Early Start (Setup Function 13): Early start allows the heating or cooling to turn on before the program start time, so the temperature is reached at the time you set. Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before restarting, to prevent damage. During the wait time, the message Cool On or Heat On (heat pumps only) will flash on the display.

Accessories & replacement parts
Please contact your distributor to order replacement parts.
Cover plate assembly*……………………………………………. Part Number 50002883-001 Use to cover marks left by old thermostats

Specifications

Temperature Ranges

  • Heat: 40° to 90°F (4.5° to 32°C)
  • Cool: 50° to 99°F (10° to 37°C)

Operating Ambient Temperature

  • 32° to 120°F (0° to 48.9°C)

Shipping Temperature

  • -20° to 120°F (-28.9° to 48.9°C)

Operating Relative Humidity

  • 5% to 90% (non-condensing)

Physical Dimensions

  •  3-7/16”H x 4-10/16”W x 1-3/16”D
    87mm H x 119mm W x 30mm D

Electrical Ratings

  • System Voltage (50/60Hz) Running Current
  • Heat (1st stage) 20-30 Vac 0.02-1.0 A
  • (Powerpile) 750 mV DC 100 mA DC
  • Auxiliary heat 20-30 Vac 0.02-1.0 A
  • Cooling 20-30 Vac 0.02-1.0 A

Resideo Inc., 1985 Douglas Drive North Golden Valley, MN 55422 69-2800EFS—05 M.S. Rev. 03-22 | Printed in the United States © 2022 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates