Honeywell LR-HWLV-HVAC TouchPRO Wireless Thermostat
System Types
- Gas, oil, or electric heat with air conditioning
- Warm air, hot water, high efficiency furnaces, heat pumps, steam, gravity
- Heat only — including power to open and close zone valves (Series 20), and normally open zone valves
- Heat only with fan
- Cool only
- 750 mV heating systems
MERCURY NOTICE
This thermostat does not contain mercury. However, do not place your old thermostat in the trash if it contains mercury in a sealed tube. Contact the Thermostat Recycling Corporation at www. thermostat-recycle.org or 800.238.8192 for information on how and where to properly and safely dispose of your old thermostat.This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate
Wallplate installation
- Separate wallplate from thermostat.
- Mount wallplate as shown below.
Battery Replacement
The TouchPRO Wireless thermostat has a coin cell battery that retains the time and date during a power failure. Under normal circumstances the coin cell should last five years. Should the time and date need to be reset after a power failure, this is an indication that the coin cell needs to be replaced. You should replace the battery every five years, or before leaving home for an extended period.
Power Requirements
The TouchPRO Wireless thermostat is shipped from the factory with the coin cell installed. To keep the battery from discharging during shipment and storage, the TouchPRO Wireless thermostat is shipped with a plastic tab inserted in the battery holder. This tab must be removed during installation. Simply pull the plastic tab out of the battery tray. Make sure that the battery tray is fully inserted into the TouchPRO Wireless thermostat.
Wiring
- Remove factory-installed jumper only for two-transformer systems
- Push excess wire back into the wall opening. Plug wall opening with non-flammable insulation
Terminal Designations
Wiring guide—heat pump systems
Wiring guide—conventional systems
Verify battery function
- After receiving time and date from the TouchPRO Wireless thermostat, remove the thermostat from the wallplate.
- Wait 10 seconds and replace the thermostat.
- After a few seconds the thermostat should return to its normal display. If it does, you are done.
- Remove the battery tray, adjust the metal tabs for good contact and verify battery polarity.
- Re-install battery tray and repeat steps 1, 2 and 3.
- If battery function cannot be verified, replace battery. If thermostat does not return to its normal display, do not install the thermostat. Return it for evaluation.
Installer setup
0170 | System type | 1 | 1 heat/1 cool conventional |
2 | 1 heat/1 cool heat pump (no aux. heat) | ||
3 | Heat only (2-wire systems) | ||
4 | Heat only with fan | ||
5 | Hot water Series 20 system (power to open & close zone | ||
valves/normally open zone valves) | |||
6 | Cool only | ||
7 | 2 heat/1 cool heat pump (with aux. heat) | ||
8 | 2 heat/2 cool multistage conventional | ||
9 | 2 heat/1 cool multistage conventional | ||
10 | 1 heat/2 cool multistage conventional | ||
11 | 2 heat/2 cool heat pump (no aux. heat) | ||
12 | 3 heat/2 cool heat pump (with aux. heat) | ||
0173 | Heat pump type | 0 | Air to air heat pump |
1 | Geothermal heat pump | ||
0180 | Fan control | 0 | Gas/Oil heat (equipment controls heating fan) |
(heating) | 1 | Electric furnace (thermostat controls heating fan) | |
0190 | Changeover valve | 0 | O/B terminal controls valve in cooling |
(O/B terminal) | 1 | O/B terminal controls valve in heating | |
0200 | Auxiliary Heat | 0 | Electric backup heat |
1 | Fossil fuel backup heat | ||
0210 | External Fossil Fuel | 0 | None |
Kit | 1 | Yes | |
0220 | 1st Stage Cool/ Compressor cycle rate | 3 | Recommended for most compressors
[other options: 1, 2, 4, 5, or 6 CPH] |
0230 | 2nd Stage Cool/ Compressor cycle rate | 3 | Recommended for most compressors
[other options: 1, 2, 4, 5, or 6 CPH] |
0240 | First stage heat | 5 | Gas or oil furnaces of less than 90% efficiency |
cycle rate (CPH= | 1 | Steam or gravity systems | |
cycles per hour) | 3 | Hot water systems & furnaces of 90%+ efficiency | |
9 | Electric furnaces | ||
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH] | |||
0250 | Second stage heat | 5 | Gas or oil furnaces of less than 90% efficiency |
cycle rate (CPH) | 1 | Steam or gravity systems | |
3 | Hot water systems & furnaces of 90%+ efficiency | ||
9 | Electric furnaces | ||
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH] | |||
0260 | Third stage heat | 9 | Electric auxilliary heat |
cycle rate (CPH) | 1 | Steam or gravity systems | |
3 | Hot water systems & furnaces of 90%+ efficiency | ||
5 | Gas or oil furnaces of less than 90% efficiency | ||
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH] | |||
0280 | Backlight | 0 | Backlight ON for approx. 8 seconds after keypress |
1 | Backlight always on low intensity, full bright after | ||
keypress |
0300 | Manual/Auto | 1 | Automatic changeover (Heat/Cool/Auto/OFF) |
changeover | 0 | Manual changeover (Heat/Cool/OFF) | |
0320 | Temperature | 0 | Fahrenheit ( ºF) |
display | 1 | Celsius ( ºC) | |
0340 | Remote Temperature | 0 | None |
Sensor | 1 | Outdoor for Display | |
2 | Outdoor for Control | ||
3 | Remote Indoor | ||
0345 | Dual Fuel Heat Pump | 0 | Balance point only |
Control | 1 | Balance point + Failed to Maintain Heat protection | |
2 | Low lockout + High Lockout + Failed to Maintain | ||
protection in between. | |||
0346 | Dual Fuel Heat Pump | 0 | Disabled |
Upstage to Furnace | 0.5 | 0.5 hours | |
Timer | 1 | 1 hour | |
1.5 | 1.5 hours | ||
2 | 2 hours | ||
3 | 3 hours | ||
4 | 4 hours | ||
5 | 5 hours | ||
6 | 6 hours | ||
8 | 8 hours | ||
10 | 10 hours | ||
12 | 12 hours | ||
14 | 14 hours | ||
16 | 16 hours | ||
0347 | Drop Temperature | 2 | 2 ºF 1.0 ºC |
3 | 3 ºF 1.5 ºC | ||
4 | 4 ºF 2.0 ºC | ||
5 | 5 ºF 2.5 ºC | ||
0350 | HP Compressor | 40 | 40 ºF 4.5 ºC |
Lockout also Balance | 0 | None | |
Point | 5 | 5 ºF -15.0 ºC | |
10 | 10 ºF -12.0 ºC | ||
15 | 15 ºF -9.5 ºC | ||
20 | 20 ºF -6.5 ºC | ||
25 | 25 ºF -4.0 ºC | ||
30 | 30 ºF -1.0 ºC | ||
35 | 35 ºF 1.5 ºC | ||
45 | 45 ºF 7.0 ºC | ||
50 | 50 ºF 10.0 ºC | ||
55 | 55 ºF 13.0 ºC | ||
60 | 60 ºF 15.5 ºC |
0360 | HP Aux Lockout | 40 | 40 ºF | 4.5 ºC |
0 | None | |||
5 | 5 ºF | -15.0 ºC | ||
10 | 10 ºF | -12.0 ºC | ||
15 | 15 ºF | -9.5 ºC | ||
20 | 20 ºF | -6.5 ºC | ||
25 | 25 ºF | -4.0 ºC | ||
30 | 30 ºF | -1.0 ºC | ||
35 | 35 ºF | 1.5 ºC | ||
45 | 45 ºF | 7.0 ºC | ||
50 | 50 ºF | 10.0 ºC | ||
55 | 55 ºF | 13.0 ºC | ||
60 | 60 ºF | 15.5 ºC | ||
65 | 65 ºF | 18.5 ºC | ||
0500 | Furnace Filter 1 | 0 | Disabled | |
Change Reminder | 1 | 10 R.T. Day | ||
2 | 30 R.T. Day | |||
3 | 60 R.T. Day | |||
4 | 90 R.T. Day | |||
5 | 120 R.T. Day | |||
6 | 180 R.T. Day | |||
7 | 270 R.T. Day | |||
8 | 365 R.T. Day | |||
9 | 30 C Days | |||
10 | 60 C Days | |||
11 | 90 C Days | |||
12 | 120 C Days | |||
13 | 180 C Days | |||
14 | 365 C Days | |||
0502 | Furnace filter | 0 | Counts heat and cool | |
reminder run time equipment counts | 1 | Counts cool only | ||
0510 | Humidifier Pad | 0 | Disabled | |
Replacement | 1 | 90 C Days, 30 R.T. Days | ||
Reminder | 2 | 180 C Days, 60 R.T. Days | ||
3 | 365 C Days, 90R.T. Days | |||
0520 | UV Lamp | 0 | Disabled | |
Replacement | 1 | 365 Days | ||
Reminder | 2 | 730 Days (2 years) | ||
0580 | Compressor protection | 5 | 5 minute compressor OFF time
[Other options: 0, 1, 2, 3 or 4-minute off time] |
|
0640 | Clock format | 12 | 12-hour time (i.e., “3:30 pm”) | |
24 | 24-hour time (i.e., “15:30”) | |||
0650 | Extended fan | 0 | OFF | |
timer (heat) | 90 | Fan runs for 90 seconds after call for heat ends | ||
0660 | Extended fan | 0 | OFF | |
timer (cool) | 90 | Fan runs for 90 seconds after call for cooling ends | ||
0670 | Keypad lock | 0 | Keypad unlocked (fully functional) | |
1 | Partially locked (access to temperature settings only) |
0680 | Heat temperature | 2 | Standard temperature control (recommended) |
control | 1 | Choose if room is warmer than set temperature | |
3 | Choose if room does not reach set temperature | ||
0690 | Cool temperature | 2 | Standard temperature control (recommended) |
control | 1 | Choose if room is cooler than set temperature | |
3 | Choose if room does not reach set temperature | ||
0700 | Temperature display offset | 0 | Thermostat displays actual room temperature
[Other options: -3 ºF, -2 ºF, -1 ºF, 1 ºF, 2 ºF, 3 ºF offset (-1.5 ºC, -1.0 ºC, -0.5 ºC, 0.5 ºC, 1.0 ºC, 1.5 ºC)] |
0710 | Reset | 0 | No reset |
1 | Reset HVAC installer options to factory default (only date | ||
and time settings are retained) and remove from Lutron® | |||
system | |||
0900* | Lutron System | 0 | Remove from Lutron system |
Connection | 1 | Connected |
Installer system test
Adding the thermostat to a Lutron system
- Use the Lutron PC software to start activation mode. When a Lutron system is in activation mode, an unaddressed thermostat will show “Device Is Unaddressed” at the top of the screen.
- To activate thermostat press MORE. The thermostat will now show the connection screen and display “Press Connect” at the top of the screen.
- Press the CONNECT button. The CONNECT button will blink and the thermostat will display “Addressing” at the top of the screen.
- Return to the Lutron software and confirm thermostat activation. When activated, the thermostat will exit the connect screen and display “Device Is Addressed” at the top of the screen.
- The thermostat is now activated.
Special functions
Auto Changeover (Setup Function 0300): When set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 2 ºFapart.
Compressor Protection (Setup Function 0580): Forces the compressor to wait a few minutes before restarting, to prevent damage. During this time, the message “Wait” flashes on the display.
Accessories & replacement parts
- Please contact your distributor to order replacement parts.
- Cover plate*……………………………………………………. Honeywell Part Number 32003796-001
- Outdoor Temperature Sensor………………………… Honeywell Part Number C7089U1006
- Remote Indoor Temperature Sensor……………… Honeywell Part Number C7189U1005
- *(Use to cover marks left by old thermostats.)
Specifications
- Temperature Ranges
- Heat: 40 ºF to 90 ºF
- (4.5 ºC to 32.0 ºC)
- Cool: 50 ºF to 99 ºF
- (10.0 ºC to 37.0 ºC)
- Operating Ambient Temperature
- 0 ºF to 120 ºF (-18 ºC to 49 ºC)
- Shipping Temperature
- -30 ºF to 150 ºF (-34 ºC to 66 ºC)
- Operating Relative Humidity
- 5% to 90% (non-condensing)
- Physical Dimensions
- 4-15/16 in H x 6-9/16 in W x
- 1-7/16 in D
- (125 mm H x 166 mm W x 36 mm D)
Electrical Ratings
W Heating | 20-30 V | 0.02-1.0 A |
(Powerpile) | 750 mV | 100 mA DC |
W2 Heating | 20-30 V | 0.02-0.6 A |
Y Cooling | 20-30 V | 0.02-1.0 A |
Y2 Cooling | 20-30 V | 0.02-0.6 A |
Aux Auxiliary heat | 20-30 V | 0.02-1.0 A |
O/B Changeover | 20-30 V | 0.02-0.6 A |
E Emergency heat | 20-30 V | 0.02-1.0 A |
L Heat pump reset | 20-30 V | 0.02-0.6 A |
Optional THP9045 Wiring Module
The THP9045 Wiring Module is designed to be used with applicable thermostats in 1 Heat/1 Cool retrofit applications where only 4 wires are available. The K terminal on the thermostat can be used to operate both the fan and compressor on a single wire, and the module is designed to receive the signal from the K terminal, split that signal and reroute it to operate the compressor, and/or fan for normal operation. See the THP9045 manual for further details.
Technical Assistance
- 24 hours a day, 7 days a week
- www.lutron.com
- U.S.A. / Canada: 1.800.523.9466
- Mexico: +1.888.235.2910
- Other Countries: +1.610.282.3800
Warranty: For warranty information, please see the Warranty enclosed with the product, or visit www.lutron.com/resiinfo
Technical Assistance
- 24 hours a day, 7 days a week
- www.lutron.com
- U.S.A. / Canada: 1.800.523.9466
- Mexico: +1.888.235.2910
- Other Countries: +1.610.282.3800
Lutron
- Lutron Electronics Co., Inc.
- 7200 Suter Road
- Coopersburg, PA 18036-1299
- USA
- TEL: +1.610.282.3800
- FAX: +1.610.282.1243
- www.lutron.com
Honeywell
- Honeywell International Inc.
- 1985 Douglas Drive North
- Golden Valley, MN 55422
- http://yourhome.honeywell.com
Reference