This thermostat is designed to control an electric heating system such as a baseboard heater, a radiant ceiling, a convector or a fan-forced heater. The thermostat CAN NOT be used with:

 WARNING Electrical Shock Hazard.

This thermostat is a line voltage control (120­240 Volts). Do not install it if you are not completely familiar with house wiring. If handled improperly, there is risk of electric shock hazard, which may cause serious injury or death.

Do you need assistance? We are here to help.
Call 1-800-468-1502 for wiring assistance before returning the thermostat to the store.

 ATTENTION: MERCURY RECYCLING NOTICE

This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash.
For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at www.thermostat-recycle.org.
For mercury thermostat recycling in Canada, please refer to Switch the Stat at www.switchthestat.ca

SUPPLIED PARTS

Installation

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.

Wiring

Connect the thermostat wires to the heating system (load) and to the power supply using solderless connectors for copper wires.

Mounting the thermostat

Loosen the screw underneath the thermostat and separate the faceplate from the wallplate.

NOTE: The screw remains captive and cannot be completely removed. Mount the wallplate to the electrical box using the provided screws. Insert the screws through the two left or the two right mounting holes of the wallplate. Reinstall the faceplate onto the wallplate and tighten the screw underneath the thermostat.

NOTE: If there is a protective film or sticker on the thermostat’s screen, peel it off. Apply power to the heating system. Verify the installation by checking that the heating system can be turned On by raising the setpoint using the Up button or turned Off by lowering the setpoint using the Down button.

 WARNING
Keep the thermostat’s air vents clean and free from obstructions.

Controls

Display

Clock and day setting

The clock must be set when Time appears on the screen.

  1. Pull the cover down.
  2. Press the Day button to set the day.
  3. Use the Hour and Min buttons to set the clock.
  4. Press the Ret button to exit.

Temperature display and setting

The thermostat normally displays the room (measured) temperature.

Automatic mode

To place the thermostat in Automatic mode, press the Mode button until Auto appears on the screen. The current period number also appears.
In this mode, the thermostat follows the programmed schedule. You can program up to 4 periods in a day. You can set 2 different programs: one for the weekdays (Monday to Friday) and another one for the weekend (Saturday and Sunday).
By default, the thermostat is programmed with the following schedule:

Monday to Friday Saturday & Sunday
Period Start Time Temperature Start Time Temperature
1 Wake 6:00 21.0 °C (70 °F) 6:00 21.0 °C (70 °F)
2 Leave 8:00 16.5 °C (62 °F) –:– – –
3 Return 18:00 21.0 °C (70 °F) –:– – –
4 Sleep 22:00 16.5 °C (62 °F) 22:00 16.5 °C (62 °F)

Temporary Override

You can temporarily override the current temperature using the Up or Down button. The new setpoint will be used until the end of the current period. During the override, Auto flashes on the screen.

To modify the schedule:

  1. Press the Mode button until Auto appears on the screen.
  2. Press the Pgm button. Period 1 of the weekday (Monday to Friday) program is displayed.
  3. To display another period, press the Pgm button.
  4. To toggle between the weekday (Mon to Fri) program and the weekend (Sat & Sun) program, press the Day button.
  5. Press the Hour and Min buttons to set the start time of the displayed period.
    NOTE: To cancel the period, press the Mode button. The thermostat will display –:–. During operation, the thermostat will skip over that period.
  6. Press the Up or Down button to set the temperature of the displayed period.
  7. Repeat steps 3 through 6 to set another period
  8. Press the Ret button to end programming.

Manual mode (a permanent override of schedule)

To place the thermostat in Manual mode, press the Mode button until Man appears on the screen. In this mode, any modification to the temperature must be done manually. Press the Up or Down button to set the temperature. The default setting is 21°C (70°F).

Economy mode

To place the thermostat in Economy mode, press the Mode button until Econo appears on the screen. This mode is ideal for weekend residences (cottages) as it can be used to keep the temperature at an economy level during most of your absence and raise the temperature to a comfortable level by your usual arrival time. If you do not show up at your cottage, the temperature will return to the economic level until the following weekend.

Period Temperature Start Time
1 Set to a comfortable level (e.g., 22°C). Set the day and time that you want the temperature to start rising so that the comfort level is reached by the time you arrive (e.g., Friday at 3:00 pm).
2 Set to an economical level (e.g., 16.5°C). Set the day and time that you want the temperature to start dropping to the economy level if you do not show up (e.g., Friday at 8:00 pm).

The Economy mode can be used as follows:

To program the two periods of the Economy mode:

  1. Press the Mode button until Econo appears on the screen.
  2. Press the Pgm button. Period 1 is displayed.
  3. Press the Day button to set the start day of the displayed period.
  4. Press the Hour and Min buttons to set the start time of the displayed period.
  5. Press the Up or Down button to set the temperature.
  6. Press the Pgm button to select Period 2.
  7. Repeat steps 3 through 5 to set Period 2.
  8. Press the Ret button to end programming.
Temporary Override

You can temporarily override the current temperature using the Up or Down button. The new setpoint will be used until the end of the current period. Econo flashes during the override.

Power outage

During a power outage, the thermostat display remains lit for the first 2 minutes. During this time, the LP (low power) indicator appears and all buttons are disabled. Then the screen turns blank. The settings are stored in memory. When power returns, the thermostat returns to the mode of operation preceding the power outage. If the power failure has exceeded 5 hours, the clock and date must be re-adjusted.

Advanced settings

  1. Pull the cover down.
  2. Briefly insert a pointed object (e.g., paperclip) through the advanced setting opening. The first parameter will appear.
  3. To display the next parameter, press the Mode button.
  4. To modify a parameter, press the Up or Down button.
  5. To exit the menu, press the Ret button or do not press any button for 1 minute.
Parameter and options Display and Default Setting Parameter and options Display and Default Setting
Temperature display format
  • °C / °F
Time display format
  • 24 h / 12 h
Early Start *
  • OF (Off) / On
Automatic Daylight Saving Time **
  • OF (Off) / On
Year ***
  • 00 – 99
Month ***
  • 1 – 12
Day ***
  • 1 – 31
Cycle length ****
  • Std / Fan

* Early Start is used in Automatic mode only. When Early Start is enabled (On), the thermostat determines when to start heating so the desired temperature be reached at the beginning of periods 1 and 3. When Early Start is disabled (Off), heating does not start in advance, and therefore the desired temperature will not yet be reached at the beginning of these periods.
** When Automatic Daylight Saving Time is enabled (On), the thermostat automatically switches to daylight saving time on the second Sunday of March and to normal time on the first Sunday of November.
*** Available only if Daylight Saving Time is enabled (On).
**** Generally set to a 15-second cycle (Std) as it provides better temperature control. However, set it to a 5-minute cycle (Fan) if you have a fan-forced heater to prevent premature fan motor burnout. Fan appears on the thermostat’s screen when the 5-minute cycle is selected.

Troubleshooting

Problem Solution(s)
The thermostat’s housing is hot. This condition is normal. Ensure that the heater capacity does not exceed the thermostat’s maximum load.
The wrong temperature is displayed. Correct it if any of the following situations exists:
  • The thermostat is exposed to an air draft.
  • The sticker on the thermostat’s screen has not been removed.
  • The thermostat is located near or above a heat source such as a light dimmer
The wrong time is displayed The time is not yet set or the thermostat was without power for more than 5 hours.
Temperature does not change according to the programmed schedule.
  • Ensure the thermostat is in Automatic mode
  • Check the clock and the schedule. If the thermostat is configured for a 12-hour format, ensure that PM appears on the screen when afternoon times are displayed.
LP appears on the screen or the screen is blank despite there is no power outage. The thermal circuit breaker in the heater is opened. This can happen if the heater is obstructed by furniture or curtain and has overheated, or if the thermal circuit breaker is defective or too sensitive.

Specifications

Supply: 120/240 VAC, 60 Hz
Minimum load 1.25 A (resistive only) 150 W @ 120 V AC 300 W @ 240 V AC
Maximum load 12.5 A (resistive only) 1500 W @ 120 V AC 3000 W @ 240 V AC
Display range 0 °C to 50.0 °C (32 °F to 99 °F)
Setpoint range 5.0 °C to 27.0 °C (41 °F to 81 °F)
Resolution: 0.5 °C (1 °F)
Storage temperature -20.0 °C to 50.0 °C (-4 °F to 120 °F)

1-year limited warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period, the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Reside o’s option).
If the product is defective,

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage that occurred while the product was in the possession of a consumer.
Reside o’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.

Resideo Inc., 1985 Douglas Drive North Golden Valley, MN 55422 33-00150EF-03 www.resideo.com

REFERENCE

Download Manual:

Honeywell RLV4300 Programmable Thermostat Owner’s Manual

Other manuals

Honeywell Home RLV4300 Programmable Thermostat User Guide

 

Honeywell logo

Honeywell Home RLV4300 Programmable Thermostat Owners Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)