Introduction
The Honeywell CM507 is a programmable room thermostat designed to control your heating system efficiently. The following instructions explain how to install, program, and use the CM507.
Features
- 7-day heating program with factory default energy-saving schedule
- Timeline display facilitating programming
- Subtle, unobtrusive styling matching a variety of room decors
Display
Installation
NOTE: The installation must be performed by an electrician or a qualified installer.
Baseplate Installation
Choose a location approximately 1.5 m above the floor and on an inside wall. Avoid draughty areas (top of the staircase, air outlet, tc.), dead air spots (behind doors), direct sunlight, or areas near concealed pipes or chimneys.
Wiring
Installing the Batteries
Use Alkaline batteries only!
After the batteries are installed, the thermostat performs a series of tests for approximately 5 seconds. Once installed on the wall, the thermostat will display the ambient temperature. The time and day settings flash to indicate that they must be set (see section 4.1).
Completing the Installation
Basic Functions
Displaying the TemperatureThe measured temperature is normally displayed. To view the set temperature, press once on either of the buttons. The set temperature is displayed for 5 seconds along with the icon.
Setting the Temperature Press one of the buttons until the desired temperature is displayed.
Comfort and Economy TemperaturesThe thermostat has 2 preset temperature buttons:
- Comfort temperature
- Economy temperature
- To set the thermostat at the comfort temperature or economy temperature, press the corresponding preset button.
- The corresponding symbol will be displayed.
- The following table shows the use and the factory setting of each preset button.
Button | Intended Use | Default Setting |
Comfort (when the occupant is awake and at home) | 21°C | |
Economy (when the occupant is absent or asleep) | 17°C |
To modify the comfort or economy temperature:
- Set the desired temperature using the buttons.
- Press and hold the appropriate preset button until the corresponding symbol is displayed.
Control Mode
Manual
Use this mode to set the temperature at a fixed value. To use this mode, press Mode to display and set the desired temperature using the buttons or the buttons.
Automatic
Use this mode to set the temperature according to the energy-saving schedule (see sectionTo place in Automatic mode, press Mode to display .
Temporary Override
If you modify the temperature when the thermostat is in automatic mode, the new temperature will be used for the next 2 hours. Afterward, the thermostat will return to the automatic mode settings. The icon flashes during the override period.
Battery Indicator
An icon appears when the batteries need replacement. This icon will flash for 60 days, then the thermostat will cut power to the heating system. The icon disappears once the batteries are replaced. After replacing the batteries, readjust the time and day (see section 4.1).
Programming
Setting the Time and Day
- Press Clk for 3 seconds. The hour display flashes
- Set the hour using .
- Press Clk. The minute display flashes.
- Set the minutes using .
- Press Clk. The day display flashes.
- Set the day using .
- Press Exit to exit the programming mode.
Energy-saving Schedule
When the thermostat is placed in automatic mode, it switches between the comfort temperature and economy temperature according to the programmed schedule. You can set a different program for each day of the week. The preprogrammed schedule is as follows:
Monday to Friday | comfort : 6:00 to 8:00 18:00 to 22:00 |
Economy : 8:00 to 18:00 22:00 to 6:00 | |
Saturday and Sunday | Comfort : 6:00 to 22:00 |
Economy: 22:00 to 6:00 | |
Modifying the Schedule
- If not already done, set the comfort and economy temperatures (see section 3.3)
- Press Pgm. The program for Monday will appear and the first hour period (0:00 a.m. to 1:00 a.m.) is selected (flashes).
NOTE: Note: If you wish to use the same program every day, press Pgm for 3 seconds to select all the days of the week.
- Press button to advance to the next or preceding hour period respectively.
- Select the comfort or economy temperature by pressing on the corresponding button( or ).
- Repeat steps 3 and 4 for each switch point.
- To modify the program for another day, press Pgm until the day is selected and repeat steps 3 to 5.
- Press Exit to exit the programming mode.
- To access the configuration menu, press theand buttons simultaneously for 3 seconds.
- To go to the next parameter (menu item), briefly press the buttons simultaneously.
- To modify a parameter, press
- Repeat steps 2 and 3 if necessary.
- Press the buttons simultaneously for 3 seconds to exit the configuration menu.
DISPLAY | DESCRIPTION | DEFAULT | SELECTIONS |
Time Display | 12 h | 12 h or 24 h | |
1 Pump Protection | Off | On or Off | |
Number of cycles per hour | 4 | 2, 3, 4, 5 or 6 | |
¹When pump protection is On, the thermostat will activate the heating system for 15 seconds if it has not been activated for the past 24 hours. ²The corresponding cycle lengths are 2=30 min., 3=20 min., 4=15 min., 5=12 min., 6=10 min. Select the cycle according to the type of heating: Gas boiler <30k W – 10 minutes Oil boiler – 20 minutes |