Honeywell 33-00131ES Touchscreen Thermostat
Welcome
Congratulations! You’ve just purchased the world’s most advanced, easy-to-use thermostat. It has been designed to give you many years of reliable service and touchscreen climate control.
When used in conjunction with other Z-Wave-enabled devices, such as a Z-Wave controller, your thermostat settings can be changed remotely from other places in your home.
Warning
- This thermostat works with common 24-volt systems such as forced air, hydronic, heat pump, oil, gas, and electric. It will not work with millivolt systems, such as a gas fireplace, or with 120/240 volt systems such as baseboard electric heat.
- This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate - MERCURY NOTICE: Do not place your old thermostat in the trash if it contains mercury in a sealed tube. Contact the Thermostat Recycling Corporation at www.thermostat-recycle.org or 1-800-238-8192 for information on how and where to properly and safely dispose of your old thermostat.
- NOTICE: To avoid possible compressor damage, do not run the air conditioner if the outside temperature drops below 50°F (10°C).
Need help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 before returning the thermostat to the store.
Features of your Z-Wave thermostat
Congratulations! You’ve just purchased the world’s most advanced, easy-to-use thermostat. It has been designed to give you many years of reliable service and touchscreen climate control.
Features:
- One-touch temp control overrides the program schedule at any time.
- Precise comfort control keeps the temperature within 1°F of the level you set.
- Change/check reminders let you know when to service or replace filters and other critical components.
- Large touchscreen display with backlight is easy to read—even in the dark.
- Z-Wave wireless control lets you connect the thermostat to a Z-Wave network.
Your new thermostat provides:
- Adaptive Intelligent RecoveryTM
- Compressor protection
- Heat/cool auto changeover
Home screen quick reference
Once your thermostat is installed, it will display the home screen. Portions of this display will change depending on how you are viewing it. To change settings, simply press the appropriate area lightly with your finger.
Unless you change the lighting function, the screen is always lit at low intensity. When you touch the screen, the screen brightens.
Setting up your thermostat
Setting up your Z-Wave programmable touchscreen thermostat is easy. It is preprogrammed and ready to go as soon as it is installed.
- Install your thermostat.
- Set up your thermostat.
- Connect the thermostat to the Z-Wave network.
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502.
Installing your thermostat
You might need the following tools to install this thermostat:
- No. 2 Phillips screwdriver
- Drill and bits (3/16″ for drywall,
- Small pocket screwdriver 7/32″ for plaster) (optional)
- Pencil
- Hammer (optional)
- Level (optional)
- Electrical tape (optional)
- Switch OFF power to your heating/cooling system.
Important! To protect your equipment, switch OFF the power to your heating/ cooling system at the breaker box or the system switch. - Remove old thermostat faceplate and leave the wires connected.
- Take a picture of the wire connections for later reference.
- If no wire is connected to a terminal labelled C or no C terminal exists on the old thermostat, call 1-800-468-1502 for wiring assistance.
If you have an older thermostat with a sealed mercury tube, turn to page ii for proper disposal instructions.
Important! C wire is required and is the primary power source for your thermostat. Without a C wire, your thermostat will not power up.
- Label wires.
Do not label by wire colour. Use the supplied sticky tags to label wire as you disconnect it. Label wires according to the old thermostat terminal designations, not by wire color.
Note: If no tag matches a terminal designation, write the appropriate letter on a blank sticky tag. - Remove wallplate.
Remove the old wallplate from the wall after all wires have been labelled and disconnected. - Separate the thermostat and its wallplate.
On your new thermostat, grasp the finger holds on the top and bottom of the wallplate with one hand and the thermostat (front) with the other hand. Pull pieces apart. - Mount wallplate for Z-Wave thermostat.
Mount your new wallplate using screws and anchors included with the thermostat.
If necessary:- Drill 3/16-in holes for drywall.
- Drill 7/32-inch holes for plaster.
Note: You may be able to use your existing wall anchors. Hold the wallplate up to the existing anchors to check for alignment.
Important! The Z-Wave thermostat requires a C wire to operate. The C, or common, wire brings 24 VAC power to the thermostat. Many older mechanical or battery-operated thermostats do not require a C wire. If you don’t have a C wire, try:
Looking for an unused wire that is pushed into the wall. Connect that wire to C and check that it is connected to the 24 VAC common at your heating/cooling system.
Note: Not all heating/cooling systems label the 24 VAC common C. Check your system manual or contact the manufacturer to find out which terminal is the 24 VAC common.
Wiring
For conventional heating/cooling systems (natural gas, oil or electric furnace, air conditioner), see page 6. See “Glossary” on page 25 for further definition. For a heat pump system, see page 6. See “Glossary” on page 25 for further definition.
- Wiring (conventional system)
- 7A Wire the thermostat to your conventional system.
- a Starting with the C Wire, match the sticky tag on the wire to the terminal labels.
You must have a C wire. See page 5. - b Loosen screw, insert wire on inside edge of terminal, then tighten screw.
- c Verify wire is firmly secured by gently pulling on wire.
- d Repeat steps a–c for all other wires.
- e Push any excess wire back into the wall opening after all wires are installed.
- f Continue to page 9. Labels don’t match? See alternate wiring key on page 7.
- a Starting with the C Wire, match the sticky tag on the wire to the terminal labels.
- Wiring (heat pump system only)
7B Wire thermostat to your heat pump.- Starting with the C Wire, match the sticky tag on the wire to the terminal labels.
You must have a C wire. See page 5. - b Loosen screw, insert wire on inside edge of terminal, then tighten screw.
- c Verify wire is firmly secured by gently pulling on wire.
- d Repeat steps a–c for all other wires.
- e Push any excess wire back into the wall opening after all wires are installed.
- f Continue to page 9.
- Starting with the C Wire, match the sticky tag on the wire to the terminal labels.
- Alternate wiring (conventional system)
Use this if your wire labels don’t match the terminal labels.
Note: You must have a C wire or equivalent.
Alternate wiring key (conventional system)- Remove the metal jumper connecting R and RC only if you must connect both R and RC.
- If your old thermostat had both R and RH wires, remove metal jumper.
Connect the R wire to the RC terminal, and the RH wire to the R terminal. - Do not use the K terminal. For future use.
- Alternate wiring (heat pump system only)
Use this if your wire labels don’t match the terminal labels.
Note: You must have a C wire or equivalent. - Alternate wiring key (heat pump system only)
- Leave metal jumper between R and RC terminals in place.
- If your old thermostat had both V and VR wires, check yourhome.honeywell.com for help.
- If your old thermostat had separate O and B wires, attach the B wire to the C terminal. If another wire is attached to the C terminal, check yourhome.honeywell.com for help. Attach the wire to the O/B terminal. Set System Function 0190 to 0 (see page 18).
- If your old thermostat had an O wire and not a B wire, attach the O wire to the O/B terminal.
- If your old thermostat had separate Y1, W1 and W2 wires, check yourhome.honeywell.com for help.
- This is the system monitor. If the monitor finds a problem, you will see a red light in the upper right corner of the thermostat (shines through the cover).
- Do not use K terminal. For future use.
- 7A Wire the thermostat to your conventional system.
- Remove the battery tab.
The thermostat is shipped from the factory with the coin cell installed. To keep the battery from discharging during shipment and storage, the thermostat is shipped with a plastic tab inserted in the battery holder simply pull the plastic tab out of the battery tray. Make sure that the battery tray is fully inserted into the thermostat. - Attach thermostat to wallplate.
Align the thermostat to the wallplate and then snap into place. - Switch the heating/cooling system ON.
Important!- 10a Verify that the C wire is connected at the thermostat and at the heating/cooling system.
- 10b Make sure the heating/
The cooling system door is firmly secured. - 10c Switch power back ON for your heating/cooling system at the breaker box or its power switch.
- Set date and time.
Touch buttons to change displayed time and date.
Press and hold a button to quickly change a setting. - Determine your heating/cooling system type.
Important! Heating/cooling system type must be set so that your thermostat operates properly and does not damage your system.- 12a If you have a traditional system (single-stage heating and cooling), your thermostat is set up by default to control this system.
- 12b If you DO NOT have a single-stage heating and cooling system, You MUST change the system type by setting system function 0170.
See “Setting functions and options” on page 16.
If you are not sure of your heating/cooling system type or have other questions, go to http://yourhome.honeywell.com
Congratulations! Your thermostat is operational.
- Test your thermostat.
- 13a Press the SYSTEM button to change to heating or cooling and begin operation.
- 13b To connect your thermostat to other Z-Wave-enabled devices, continue to “Connecting to Z-Wave network” on page 10.
Connecting to the Z-Wave network
Connect to other Z-Wave-enabled devices.
The RTH8580ZW is powered by Z-Wave technology so it is compatible with Z-Waveenabled devices from other manufacturers. With a separate Z-Wave controller, for example, you can change your thermostat settings from your bedroom or elsewhere in the house.
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell
Customer Care is toll-free at 1-800-468-1502.
- Join the Z-Wave network.
- To join a Z-Wave network, set the Z-Wave controller to INCLUDE mode.
- Access system setup. See “Setting functions and options” on page 16 for information on how to access system setup.
- Press next to the four-digit function number, and scroll to function rf10.
- Press next to the single-digit option number, and select option 1 to add the thermostat to the Z-Wave network.
- Share Z-Wave network.
- Press next to the four-digit function number, and scroll to function rf20.
- Press next to the single-digit option number, and select option 1 to share the thermostat Node information with additional Z-Wave devices.
- Press Done to save changes and exit the system setup.
For an explanation of Z-Wave messages, see page 22.
Setting the clock
- Press CLOCK to display setting arrows.
- Pressto adjust the time. (You can advance the time more quickly by holding the s or t buttons.)
- Press DONE to save and exit (or press CANCEL to exit without changing the time).
Note: You should never need to adjust the real-time clock; it automatically updates for daylight saving time and all date/time information is stored.
Note: To change the current weekday format, see “System setup” on page 17.
Setting the fan
- Press FAN to select fan operation.
- Press DONE to save setting. Your selection appears under FAN.
- ON: Fan is always on.
- AUTO: Fan runs only when the heating or cooling system is on.
- CIRC: Fan runs randomly, about 35% of the time, including any run time with the heating or cooling system.
Note: You can press FAN to override the fan settings you’ve programmed for different time periods. If you select ON or CIRC, the setting you select will remain active until you press FAN again to select AUTO.
Note: If a fan schedule is programmed, “Auto” will run the fan schedule.
Selecting system mode
- Press SYSTEM to display options.
- Press DONE to save the setting. Possible system modes:
- HEAT: Controls only the heating system.
- COOL: Controls only the cooling system.
- OFF: Heating/cooling systems are off.
- AUTO: Selects heating or cooling depending on the indoor temperature. EM HEAT (heat pumps with aux. heat): Controls auxiliary/emergency heat. The compressor is locked out.
Setting filter reminder intervals
If activated during installation, the filter reminder alerts you with a message above the time when it is time to replace your filter.
Press RESET after changing the filter, to restart the timer.
To change the reminder interval:
- Press MORE, then EDIT.
- Press to select the desired interval (in days), then press DONE.
- Press RESET.
- Press DONE to save and exit.
Note: System setting function 0500 governs the filter interval. See “System setup” on page 19.
Screen lock
To prevent tampering, the screen can be partially or fully locked.
When partially locked, the screen displays SCREEN LOCKED for several seconds if a locked key is pressed. To unlock the screen, press any unlocked key while SCREEN LOCKED appears on the screen.
When the screen is fully locked, no keys function.
To lock or unlock the screen, see function 0670 on page 20.
Cleaning the screen
- Press SCREEN to lock the screen for cleaning.
The screen will remain locked for 30 seconds so you can clean the screen without changing any settings. - After 30 seconds, press DONE to resume normal operation, or press SCREEN again if you require more time for cleaning.
Note: Do not spray any liquid directly on the thermostat. Spray the liquid onto a cloth, then use the damp cloth to clean the screen. Use water or household glass cleaner. Avoid abrasive cleansers.
Remove from Z-Wave network
- Access system setup. See “Setting functions and options” on page 16 for information on how to access system setup.
- Press next to the four-digit function number, and scroll to function rf10.
- Pressnext to the single-digit option number, and select option 0 to remove the thermostat from the Z-Wave network.
Adaptive Intelligent Recovery
This feature allows the thermostat to “learn” how long the heating/cooling system takes to reach programmed temperature settings, s the temperature is reached at the time you set.
For example: Set the Wake time to 6:00 am, and the temperature to 70°. The heat will come on before 6:00 am, so the temperature is 70° by 6:00 am.
Note: System setting function 0530 controls Adaptive Intelligent Recovery. See “System setup” on page 19
Compressor protection
This feature forces the compressor to wait a few minutes before restarting, to prevent equipment damage.
Auto changeover
This feature is used in climates where both air conditioning and heating are used on the same day.
When the system is set to AUTO, the thermostat automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 3 degrees apart. The thermostat will automatically adjust settings to maintain this 3-degree separation.
Note: System setting function 0300 controls Auto changeover. See “System setup” on page 18.
Setting functions and options
You can change options for a number of system functions. Available functions depend onthe type of system you have. The functions, designated with four-digit numbers, along withavailable options are described on pages 17–20.
This thermostat is pre-set for a single-stage heating/cooling system.
Setting function 0170 for a heat pump will adjust the default settings.
- Press SYSTEM. You’ll see several blank buttons on the bottom of the display.
- Press and hold the buttons on either side of the center button until the screen changes (approximately 5 seconds).Cycle through the functions, press next to the four digit number on the left.
- As needed, change options for any function by pressing next to the number on the right.
- When you have made all changes, press DONE to save and exit.
System setup
How do I change time and date settings? (See page 16 for instructions)
Function Settings & Options
0120 | Year Setting
(first two digits) |
20 = Year 20xx
21 = Year 21xx |
0130 | Year Setting (last two digits) | 01–99 (i.e., 2001–2099) |
0140 | Month Setting | 01–12 (i.e., January–December) |
0150 | Date Setting | 01–31 |
0160 | Schedule Options | 4 Program schedule is on (7-day programmable).
0 Program schedule is off. The thermostat cannot be programmed. |
0165 | Restore Schedule Defaults | 0 Continue using a programmed schedule. 1 Restore the thermostat program to energy-saving settings |
Function | Settings & Options | |
0170 | Select System Type If you are not sure of your heating/cooling system type or have other questions, go to http://yourhome.honeywell.com | 1 Heat/cool: Gas, oil or electric heating with central air conditioning |
2 Heat pump: Heat pump without backup or auxiliary heat. | ||
3 Heat only (2-wire systems): | ||
4 Heat only with fan: Gas, oil or electric heat without central air conditioning. | ||
5 Heat only (no fan): Gas, oil or hot water heat without central air conditioning | ||
6 Cool only: Central air conditioning only. | ||
7 Heat pump: Heat pump with backup or auxiliary heating. 8 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 cooling stages (wires on Y and Y2). 9 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 cooling stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on W), 2 cooling stages (wires on Y and Y2). 11 2Heat/2Cool Heat Pump (no aux. heat): 12 3Heat/2Cool Heat Pump (with aux. heat): |
0180 | Heating Fan Control | 0 Gas or oil heat: Use this setting if you have a gas or oil heating system (system controls fan operation).
1 Electric heat: Use this setting if you have an electric heating system (thermostat controls fan operation). |
0190 | Heat Pump Changeover Valve (for heat pumps only) | 0 Cooling changeover valve: Use this setting if you connected a wire labeled “O” to the O/B terminal.
1 Heating changeover valve: Use this setting if you connected a wire labeled “B” to the O/B terminal. |
0220 | 1st Stage compressor cycle rate | 3 Recommended for most compressors [Other options: 1, 2, 4, 5 or 6 CPH] |
0230 | 2nd Stage compressor cycle rate | 3 Recommended for most compressors [Other options: 1, 2, 4, 5 or 6 CPH] |
0240 | Heating Cycle Rate | 5 Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).
9 Electric furnace: Electric heating systems. 3 Hot water or high-efficiency furnace: Hot water system or gas furnace (more than 90% efficiency). 1 Gas/oil steam or gravity system: Steam or gravity heat systems. [Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH] |
0250 | Heating Cycle Rate Stage 2 | |
0260 | Heating Cycle Rate Stage 3 | |
0270 | Emergency Heat Cycle Rate (CPH) |
0280 | Backlight | 0
1 |
Backlight off, then on for approximately 45 seconds after a keypress. Backlight always on low intensity, full bright after keypress (requires 24VAC connection). |
0300 | Manual/Auto Changeover
See page 16 for more information. |
0
1 |
Manual changeover (Heat/Cool/Off).
Automatic changeover (Heat/Cool/Auto/Off). Automatically turns on Heat or Cool based on room temperature. |
0310 | Auto changeover deadband | 3 | Heat/cool temperature 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)]) |
0320 | Temperature Format (°F/°C) | 0
1 |
Fahrenheit Celsius |
0330 | Automatic Daylight Saving Time Adjustment | 0
1 |
Off On |
Function Settings & Options | ||
0500 | Filter Change Reminder
The reminder appears after selected number of days run time not actual time. |
0 Off (no reminder)
1 Reminder after 10-day run time (about 1 calendar month) 2 Reminder after 30-day run time (about 3 calendar months) 3 Reminder after 60-day run time (about 6 calendar months) 4 Reminder after 90-day run time (about 9 calendar months) 5 Reminder after 120-day run time (about 1 calendar year) 6 Reminder after 180-day run time (about 18 calendar months) 7 Reminder after 270-day run time (about 2 calendar years) 8 Reminder after 365-day run time (about 3 calendar years) 9 30 calendar days 10 60 calendar days 11 90 calendar days 12 120 calendar days 13 180 calendar days 14 365 calendar days |
0502 | Furnace Filter for Run Time | 1 Counts both heat and cool
0 Counts cool only |
0520 | UV Lamp Replacement | 0 Disabled
1 365 days 2 730 days |
0530 | Adaptive Intelligent RecoveryTM
See page 15 for more information. |
1 On
0 Off |
0540 | Program Periods | 4 4 program periods (Wake, Leave, Return, Sleep)
2 2 program periods (Wake, Sleep) |
0580 | Compressor Protection | 5 5-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time) |
0600 | Heat Temperature Range Stop | 90 Max. heat temperature setting is 90°F (32°C) [Other options: 40-89°F (4°C to 32°C)] |
0610 | Cool temperature range stop | 50 Min. cool temperature setting is 50°F (10°C) [Other options: 51-99°F (11°C to 37°C)] |
0615 | Energy Saving Heat Setpoint | 65 65°F (18.5°C)
40-90°F (4.5°C to 32°C) |
0616 | Energy Saving Cooling Setpoint | 78 78°F (25.5°C)
50-99°F (10°C to 37°C) |
0640 | Clock Format | 12 12-hour clock (i.e., “3:30 pm”)
24 24-hour clock (i.e., “15:30”) |
0650 | Extended fan timer (heat) | 0 Off
90 Fan runs for 90 seconds after call for heat ends [Other options: 30, 60, 120] |
0660 | Extended Fan Timer (cool) | 0 Off
90 Fan runs for 90 seconds after call for cooling ends [Other options: 30, 60, 120] |
Function Settings & Options | ||
0670 | Keypad Lock | 0 Keypad unlocked (fully functional)
1 Partially locked (access to temperature settings only) 2 Fully locked |
0680 | Heat temperature control | 2 Standard temperature control (recommended)
1 Choose if room is warmer than set temperature 3 Choose if room does not reach set temperature |
0690 | Cool temperature control | 2 Standard temperature control (recommended)
1 Choose if room is cooler than set temperature 3 Choose if room does not reach set temperature |
0700 | Temperature display offset | 0 Thermostat displays actual room temperature
[Other options: -3, -2, -1, 1, 2, 3°F offset (-1.5°C to 1.5°C)] |
0710 | Restore Original Settings | 0 No reset
1 Reset installer options, the Z-Wave Radio module, & programming schedule to factory default (only date and time settings are retained). |
RF10 | Z-Wave Network Connection | 0 Remove
1 Add |
RF20 | Z-Wave Node Connection | 0 Idle
1 Send node |
System test
- Press SYSTEM. You’ll see several blank buttons on the bottom of the display.
- Press and hold the buttons on either side of the center button until the screen changes (approximately 5 seconds).
- Repeatedly press t next to the four digit function number until “Test” appears.
- Press t next to “Test” to select test type.
- Press t next to the 0 to change system status.
- Press DONE to terminate testing.
See next page for system test types and status options.
System test System status
1 | Cooling system | 0 Compressor and fan turn off
1 Compressor and fan turn on 2 Second stage compressor turns on |
2 | Fan system | 0 Fan turns off
1 Fan turns on |
3 | Heating system | 0 Heat and fan turn off
1 Heat turns on (fan on if Function 0170 is set for heat pump, or if Function 0180 is set to “1”) 2 Second stage heat turns on |
4 | Emergency heating system | 0 Em Heat and fan turn off
1 Em Heat and fan turn on 2 Second stage heat turns on (Auxiliary heat) |
Important!
EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing.
To prevent equipment damage, avoid cycling the compressor quickly.
Z-Wave messages
Add/Remove | The thermostat can be included or excluded from the Z-Wave network. This action requires the controller set in inclusion mode. The device is included to the Z-Wave network after sending the node information to the controller. The controller is responsible for assigning the home ID and device ID to the included device. The thermostat can also act as a repeater to forward
messages to other devices in the Z-Wave network. Repeating messages allows communication of devices that are not in the direct reach of Z-wave protocol. |
Association | The thermostat can be associated with other devices in the system. Being associated means that the thermostat is able to send messages directly to any other device. During the association process the return route is acquired from the primary controller. The thermostat then uses this return route to access the distant node. The association is a connection between primary and secondary devices. It is used to determine the relationship of devices in the network. Both primary and secondary controllers can set up associations. |
|
The thermostat supports one association grouping and five nodes can be associated with this grouping. The following messages are sent to associated nodes for grouping #1:
• Basic • Multilevel Sensor • Thermostat Mode • Thermostat Setpoint • Thermostat Fan Mode • Thermostat Operating State • Thermostat Fan State |
Enter/leave Power Savine Mode
|
When requested from the Z-Wave controller, the thermostat adjusts its setpoint in order to decrease the power consumption of the HVAC equipment.
In addition, using an Internet gateway enables the person to control the thermostat remotely through the Internet. |
Thermostat. Fan Mode Change
|
The thermostat can send a message containing the actual fan mode position. |
Thermostat Fan Mode | The other devices can change the fan mode of the thermostat. After the message is received, the fan mode is changed to the desired value (if this value is possible).
For the thermostat, the possible values are On, Auto and Circ. |
Indoor Temperature | The thermostat sends the indoor temperature using the Multilevel Sensor command class. |
Report. upon GET request.
|
Upon request (GET command) the thermostat sends the corresponding report. |
Setroint Value |
The thermostat can send the message containing the actual setpoint value based on the setpoint change. |
Setpoint. Change
|
Other Z-Wave devices are able to modify the setpoint of the thermostat. The absolute value can be sent by the controller and the thermostat will change the setpoint to this value. |
Thermostat Mode Change
|
The thermostat can send a message containing the actual thermostat mode based on the thermostat mode change. |
Thermostat Mode |
Other devices (controllers) can change the thermostat mode change of the thermostat. After the message is received by the thermostat, the
thermostat mode change is changed to the desired value (if this value is possible). Seven possible modes are available for the thermostat: Heat / Cool / Off / Auto / Energy Saving Heat / Energy Saving Cool / Em Heat. The number of allowed selections depends on the actual configuration of the thermostat. The thermostat uses the “Thermostat Mode Supported” report command class to tell other devices the supported thermostat modes. |
Thermostat Operating State
|
The thermostat can send a message containing the actual state of the HVAC equipment based on equipment state change.
The thermostat provides the following operating states: • Idle – no equipment on • Heating – heating equipment on • Cooling – cooling equipment on • Pending Heat – minimum off time applied to protect the heat pump compressor • Pending Cool – minimum off time applied to protect the heat pump compressor |
Unsolicited
|
Sending the message is possible only if the thermostat is associated with any other node. The thermostat will send the message using the assigned node ID and return route. |
Troubleshooting
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.
Display is blank | • Check circuit breaker and reset if necessary.
• Make sure the power switch at the heating and cooling system is on. • Make sure furnace door is closed securely. • Make sure C wire is connected (see page 5). |
Cannot change a system setting to Cool | • Check Function 0170: System Type to make sure it is set to match your heating and cooling equipment (see page 17). |
The fan does not turn on when heat is required | • Check Function 0180: Heating Fan Control to make sure it is set to match your heating equipment (see page 18). |
“Wait” appears on the screen | • Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor. |
Heat pump issues cool air in heat mode, or warm air in cool mode | • Check Function 0190: Heat Pump Changeover Valve to make sure it is properly configured for your system (see page 18). |
Button on lower right of screen is blank | • This button will remain blank unless the furnace filter change reminder is activated (see page 13). |
Red light is on | • If thermostat is in Emergency Heat mode the red light is normal. It shows that the thermostat is in emergency heat mode.
• If thermostat is not in Emergency Heat mode, contact a qualified service contractor for repair. |
Heating or cooling system does not respond | • Press SYSTEM to set system to Heat. Make sure the temperature is set higher than the Inside temperature.
• Press SYSTEM to set system to Cool. Make sure the temperature is set lower than the Inside temperature. • Check circuit breaker and reset if necessary. • Make sure power switch at heating & cooling system is on. • Make sure furnace door is closed securely. • If “Wait” is displayed, the compressor protection timer is on. Wait 5 minutes for the system to restart safely, without damaging the compressor. |
Heating system is running in cool mode | • Check Function 0170: System Type to make sure it is set to match your heating and cooling equipment (see page 17). |
Glossary
- C wire
The Z-Wave thermostat requires a C wire to operate. The “C” or common wire brings 24 VAC power to the thermostat from the heating/cooling system. Some older mechanical or battery-operated thermostats may not have this wire connection. - Heat Pump heating/cooling system
Heat pumps are used to heat and cool a home. If your old thermostat has a setting for auxiliary or emergency heat, you likely have a heat pump. - Conventional heating/cooling system
Non–heat pump-type systems; include air handlers, furnaces or boilers that run on natural gas, oil or electricity. They may or may not include an air conditioner. - Jumper
A small piece of wire that connects two terminals
1-year limited warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option). If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or (ii) call Honeywell Customer Care at 1-855-733-5465. Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN
55422 or call 1-855-733-5465. . In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive,Toronto, Ontario M1V4Z9.
Regulatory information
FCC Compliance Statement (Part 15.19) (USA only)
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USA only)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radioor television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Thermostats
To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Section 7.1.2 of RSS-GEN
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Section 7.1.3 of RSS-GEN
Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
Automation and Control Systems
Honeywell International Inc.
1985 Douglas Drive North Golden Valley, MN 55422
http://yourhome.honeywell.com
® U.S. Registered Trademark.
Z-Wave is a registered trademark of Sigma Designs, Inc. and/or its subsidiaries.
© 2015 Honeywell International Inc.
33-00131ES—01 M.S. 06-15
Printed in U.S.A.