Honeywell Home CT60 Non-Programmable Thermostat
Application
Your new CT60 Series Electric Heating Thermostats provide line voltage control of electric baseboard healing systems within the ratings listed on the front of this instruction sheet. CT6OA replaces 2 wire thermostat; CT60B replaces 4 wire thermostat. Wire connectors are not supplied. Use certified wire connectors approved for No. 12 wires.
WARNING Electrical Shock Hazard.
This thermostat is a line voltage control (120–240 Volts). Do not install it if you are not completely familiar with house wiring. If handled improperly, there is risk of electric shock hazard, which may cause serious injury or death.
Specifications
- CT60A single-line break 2 wires
- CT60B double-line break in OFF position—4 wires
Temperature Range: 10° C to 30°C temperature range
Electrical Ratings: 60 Hz noninductive; 22A at 120-240 Vac; 19A at 277 Vac
ATTENTION: MERCURY RECYCLING NOTICE
This product does not contain mercury.
However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash.
For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at www.thermostat-recycle.org.
For mercury thermostat recycling in Canada, please refer to Switch the Stat at www.switchthestat.ca
Preparation for Installation
- Before proceeding, first, turn off power to the healing system at the main fuse or circuit breaker panel. See warning note.
- When replacing your old thermostat, remove the two mounting screws of your old thermostat and pull out of the junction box.
- Label the wires in the junction box, so that they match the thermostat wires to which they are attached.
- Disconnect the old thermostat.
Wiring and Installation
- When installing your new thermostat, remove the pre-stripped insulation tips from your new thermostat´s leads.
- Re-connect wires in the junction box to match the lead wires on the back of the thermostat. See the wiring diagram below.
NOTE: Do not connect power supply LI-L2 to L1-TI, to avoid thermostat burn-out.
CAUTION
Use certified solderless wire connectors (not included) approved for No. 12 wires and tighten them firmly so they cannot be pulled off.
Failure to tighten firmly may cause an overheated connection. - Remove the thermostat cover.
- Mount the thermostat to the junction box using the two captive screws provided. Do not press the knob or bimetal sensing element during mounting.
- Replace the thermostat cover.
Wiring
- The power supply provides disconnect means and overload protection as required.
- Special service co/air solderless connectors must be used when connecting with aluminum conductors. Otherwise, a fire hazard may result.
- L1-T1 closes on temperature fall.
- The power supply provides disconnect means and overload protection as required.
- Special service co/air solderless connectors must be used when connecting with aluminum conductors. Otherwise, a fire hazard may result.
- L1-T1 closes on temperature fall.
L2-T2 opens only in the off position.
Check Out Thermostat
- Turn the temperature setting dial fully counterclockwise
.
- Turn the power back on.
- Turn the temperature setting dial fully clockwise
and listen for the “click” sound as the switch makes contact. The electric heater should warm up within 2 – 10 minutes.
- Turn the temperature setting dial fully counterclockwise
and listen for the “click” sound as the switch breaks contact Electric heater should shut off and cool down.
- Set the dial to a normal comfort temperature.
Troubleshooting
Your thermostat requires little or no attention. Most problems can generally be traced to the following:
Symptom | Checkout | Action |
No heat. | Blown fuse or tripped circuit breaker. | Replace the fuse or reset a breaker |
Improper connections to the thermostat. | With the power to circuit OFF, tighten all wiring connections. Repair any frayed or broken wires. | |
Other. | Contact a qualified electrician for assistance. | |
The heater never turns off. | Turn the temperature setting dial fully counterclockwise![]() |
1. Electric heater should start to cool within 2-10 minutes.
2. If the heater does n start to cool then turn off power at the main service panel and reconfirm that wiring is in accordance with wiring diagram. |
Other | Contact a qualified service technician for assistance |
1-year limited warranty
Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period, the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Reside o’s option).
If the product is defective,
- return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
- call Resideo Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage that occurred while the product was in the possession of a consumer.
Reside o’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422, or call 1-800-468-1502.
Resideo Inc., 1985 Douglas Drive North Golden Valley, MN 55422 www.resideo.com
This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502
© 2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc.
All rights reserved.
REFERENCE
Download Manual:
Honeywell Home CT60 Non-Programmable Thermostat Owner Manual
Honeywell Home CT60 Non-Programmable Thermostat Owner Manual
Leave a Reply