PRECAUTIONS FOR USE

NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT

REMOTE CONTROLLER

Precautions for UseHitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-2

VARIOUS FUNCTIONS

Auto Restart Control

AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT, COOL, or DEHUMIDIFY depending on the current room temperature. The selected mode of operation will change when the room temperature varies. However, the mode of operation will not change when the indoor unit is connected to the multi-type outdoor unit.

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-3

HEATING OPERATION

Defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchange of the outdoor unit, for 5~10 minutes each time. During defrosting operation, the operation lamp blinks in a cycle of 3 seconds on and 0.5 seconds off. The maximum time for defrosting is 20 minutes. However, if it is connected to a multi-type of outdoor unit, the maximum time for defrosting is 15 minutes. (If the piping length used is longer than usual, frost will likely form.)

Defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchange of the outdoor unit, for 5~10 minutes each time. During defrosting operation, the operation lamp blinks in a cycle of 3 seconds on and 0.5 seconds off. The maximum time for defrosting is 20 minutes. However, if it is connected to a multi-type outdoor unit, the maximum time for defrosting is 15 minutes. (If the piping length used is longer than usual, frost will likely form.)

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-5

Dehumidifying Function

COOLING OPERATION

Use the device for cooling when the outdoor temperature is 21~43°C. If indoor humidity is very high (80%), some dew may form on the air outlet grille of the indoor unit.

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-6

FAN OPERATION
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor unit at the end of the summer

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-7

FAN SPEED (AUTO) ….. When the AUTO fan speed mode is set in the cooling/heating operation:

For the heating operation

For the cooling operation

HOW TO SET THE SLEEP TIMER

Set the current time first if it is not set before (see the pages for setting the current time). Press the (SLEEP) button, and the display changes as shown below.

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-8

How to Cancel Reservation
Point the signal window of the remote controller toward the indoor unit, and press theHitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-9 (CANCEL) button. TheHitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-10 (RESERVED) sign goes out with a beep and the (TIMER)Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-10 lamp turns off on the indoor unit.

HOW TO SET THE TIMER

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-11Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-11

How to Cancel Reservation
Point the signal window of the remote controller toward the indoor unit, and press theHitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-9 (CANCEL) button. The (RESERVED)Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-10 sign goes out with a beep and the (TIMER)Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-10 lamp turns off on the indoor unit

NOTE
You can set only one of the OFF-timer, ON-timer, and ON/OFF-timer.

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-13Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-14

HOW TO INSTALL WIRELESS REMOTE CONTROL

HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER

Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-18

CAUTION

  1.  Do not use new and old batteries, or different kinds of batteries together.
  2.  Take out the batteries when you do not use the remote controller for 2 or 3 months.

TEMPORARY SWITCH
Use the temporary switch when an operation cannot be done with the remote controller.

  1. By pressing the temporary switch, the operation is done in the previously set operation mode. When the operation is done using the temporary switch after the
    power source is turned off and turned on again, the operation is
  2. When the operation is stopped or when the operation is done with the remote controller again. Press the temporary switch once again.Hitachi-SPX-RCKA2-S-Series-Wireless-Controller-THERMOSTAT-fig-19

CIRCUIT BREAKER
When you do not use the room air conditioner, set the circuit breaker to “OFF”.

HOW TO INSTALL THE DISPLAY PANEL

CAUTION Please disconnect the wired remote controller or Weekly Timer connector at CN1102 if using the wireless remote controller.

Reference:

Download Manual:

Hitachi SPX-RCKA2 S-Series Wireless Controller THERMOSTAT User Manual

Hitachi-logo

Hitachi SPX-RCKA2 S-Series Wireless Controller THERMOSTAT User Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)