Hitachi-LOGO

HITACHI ATW-RTU-07 Wireless Intelligent Room Thermostat

HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-PRODUCT

SAFETY SUMMARY

DANGER

CAUTION

NOTE

FACTORY SUPPLIED ACCESSORIES

Description Quantity
ATW-RTU-07 (Receiver + Thermostat) 1
Screw and plug 4
Installation and operation manual 1
Product fiche 1

INSTALLATION INFORMATION

RF RECEIVER INSTALLATION

  1. Disconnect the main power from the system. To ensure your safety, always make sure main power is switched off before accessing wiring.
  2. Remove the cover from the RF receiver.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.1
  3. Mount the wiring plate to the wall or wall box.
    NOTE
    The plugs and mounting screws required are supplied.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.2
  4. Connect the RF Receiver wiring.
    • Connect the H-LINK cable.
    • Place the cable through the orifice identified by marker 3.
    • Connect the power cable (L = Live ; N =Neutral) (Tightening torque 0.50 Nm)
    • Place the power cable in the cable guide identified by marker 1.
  5. The cables must be positioned in the box’s cable guides in order to guarantee the pull-off strength.
    Item Notes
    CB Circuit Breaker 5A
    Cable 2 x 0.75 (1)

    The power cable type cannot be lighter than the specified in 60245 IEC 57.HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.3

  6. Attach the cover of the RF receiver to the wiring plate.
  7. Reconnect the main power to the system.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.4

Dimensional data
HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.5Technical data

Communication

Simplified declaration of conformity
Hereby, Johnson Controls-Hitachi declares that the radio equipment type 2 is in compliance with directive 2014/53/EU.
DSW configuration
HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.6

THERMOSTAT INSTALLATION

  1. Locate the thermostat.
    • Away from draughts
    • Away from heat sources
    • Away from direct sunlight
    • Positioned about 1.2m – 1.5m from the floor
      HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.7
      HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.8
  2. First, remove the dial.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.9
  3. Unclip the mounting plate.
    Press the top of the thermostat downwards, pull it loose and tilt forwards.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.10
  4. Mount directly to the wall.
    The plugs and mounting screws required are supplied.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.12
  5. Remove the protective tab between the batteries.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.13
  6. Attach the thermostat to the mounting plate.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.14
  7. Replace the dial.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.15

OPERATION INSTRUCTIONS

RF RECEIVER

Operation and status LED

RF receiver status ON Time OFF Time Description
Waiting 0.5 s 4 s There is no thermostat linked to the RF receiver
Normal operation Infinite There is at least 1 thermostat linked to the receiver and there are no alarms.
Alarm 150 ms 150 ms Communication fault between RF receiver and YUTAKI unit, RF communication lost with any of the wireless thermostats or Faulty RF receiver.
Binding 1 s 1 s Binding process

Reset
ATW-RTU-07 RF receiver and thermostat are already linked by default. To verify if Reset has to be performed, check section “3 Binding the Wireless thermostat and RF Receiver”
To reset the stored data in order to create a new binding in ATW-RTU-07 press the BIND button for 15 seconds.
After reset is being performed Status led shall blink according to
“Waiting” status is defined in ”2.1.1 Operation and status LED”.
HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.16RF transmission
The refresh time of the RF transmission (between the wireless room thermostat and the main controller) is ranging from 30 sec to 2 minutes.

Explanation of the icons

The setting of room temperature

The current room temperature is shown in the display. The setting temperature can be changed by turning the dial to the right to increase temperature, and to the left to reduce temperature. The setting temperature changes in 0.5ºC steps, one for each ‘click’ as the dial is turned.
HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.27The display changes to current room temperature again after five seconds have passed. Then the thermostat tries to maintain the set temperature as accurately as possible. The setting temperature can be checked by turning the dial one ‘click’ to the left or right. It will flash up for a few seconds, before returning to the display of room temperature again.

Installation menu
The single zone thermostat has an installation menu that is used to set the maximum and minimum temperature limits.
The maximum temperature that can be set on the thermostat is 35ºC and the minimum temperature is 5ºC.

Activation of the installation menu

Reset to default
Rotate the setting ring fully to the left until the minimum temperature is shown.
When the value starts flashing, touch and hold on left or right touch zones for approximately 10 s. The maximum temperature limit is now displayed flashing, touch the left or right touch zone briefly.
When the minimum temperature limit is flashing, touch again the left touch zone.
The symbol appears on the screen, touch and hold during 10 s the left touch zone and the device resets the default settings.

Replacement of the batteries

  1. Pull to remove the dial ring.
  2. Detach the thermostat from the base.
  3. Replace the batteries as shown at the picture.
  4. Attach the thermostat to the base.
  5. Place the dial ring.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.31

BINDING THE WIRELESS THERMOSTAT AND RF RECEIVER

By default the thermostat is already linked to the RF receiver. For these reason there is no need to perform binding procedure in case it is only required one wireless thermostat at the installation.
The binding operation described below is required if:

  1. Hold button on RF Receiver for 15 seconds in order to remove all the configurations. At the end of the procedure, LED will flash 0.5 seconds ON and 4 seconds OFF.
  2. Hold button on RF Receiver for 5 seconds. Led will flash for 1 seconds ON and 1 second OFF.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.32
  3. Bind the thermostat. Touch and hold on the right touch zone for approximately 10 seconds.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.33
  4. The screen for binding the RF Receiver is now displayed.
    HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.34
  5. Briefly touch the right touch zone to send the binding signal, at which point the symbol will flash several times.
  6. If binding has been successful the number indicates the signal strength (1 = min to 5 = max). If binding fails, appears on screen. Please try again.
    • Successful binding
      HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.35
    • Failed binding
      HITACHI-ATW-RTU-07-Wireless-Intelligent-Room-Thermostat-FIG.36
  7. The LED on the RF receiver is constantly ON to indicate that the RF receiver is correctly linked with a thermostat.
    NOTE
    Binding can be cancelled from the binding screen by touching and holding on the right touch zone for approximately 10 seconds.
  8. If binding is unsuccessful, LED will flash. In this case, change the location of the room thermostat and repeat the procedure.
  9. In case that there are 2 room thermostats and thermostat 1 is already linked, LED will be stay ON even if binding is unsuccessful for thermostat 2.
  10. Perform this step in case started from step 1. Repeat the procedure from step 2 to 8 to bind the second room thermostat.

NOTE

COMMUNICATION LOSS

In case of alarm the LED on the RF Receiver flashes 150 ms ON and 150 ms OFF. The following list shows which types of communication fails makes the RF receiver to enter into alarm state.

In case of alarm, check wireless thermostats and check also YUTAKI LCD Controller (PC-ARFH1E) to determine reason of alarm.
NOTE
LED also shows alarm in case of faulty RF receiver.

FAIL-SAFE MODE SETUP

The fail-safe mode defines the system status if the RF communication is lost (e.g. when the Room thermostat stops communicating due to discharged batteries).
The system will continue to operate at the last communicated setpoint.

TROUBLESHOOTING

Symptom (Fault Message) Possible Cause Remedy
The receiver box does not react to setpoint changes on the room thermostat. The room thermostat and receiver box are not bound. Reset the receiver box by pressing and holding the push button for 15 seconds. Then follow the binding/rebinding procedure as described in section 3 Binding the Wireless thermostat and RF Receiver”.
The LED shows the alarm There is no communication between YUTAKI Unit and the RF receiver. Check the H-LINK connection wire between YUTAKI Unit and the RF receiver and replace it if necessary.
The receiver box receives no RF messages from the room thermostat. Re-locate the room thermostat.
RF signal is blocked due to the wrong location of the room thermostat.
Room thermostat batteries are exhausted. Replace batteries in the room thermostat.
Faulty receiver. Change the receiver.

REFERENCE:

Download Manual:

HITACHI ATW-RTU-07 Wireless Intelligent Room Thermostat User Manual

Hitachi-LOGO

HITACHI ATW-RTU-07 Wireless Intelligent Room Thermostat User Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)