Heat decor TS10 THERMO-SWITCH SOCKET THERMOSTAT
DESCRIPTION OF CONTROLS
- selection of functions
- = selection of temperatures
- = confirmation (ENTER), information present temperature (tE: A), present time (CL:O), the sum of operating hours (SU: MA), and day (dE:n)
- the setting of temperature, time, functions
DISPLAY DESCRIPTION
OPERATING INSTRUCTIONS
After a connection in the 230V socket is TS10 immediately ready for use? If sign dO: bI is flashing on the display, the backup battery is not fully charged and it is necessary to let the TS10 in 230V-socket charge for a minimum of 2 days (a full charge takes about 4 days). After charging it is possible to remove TS10 from the socket without losing the actual time and you can provide the programming outside the 230V socket. (Maximal backup time is 100 hours). If we disconnect TS10 from the network 230V, the TS10 comes to standby mode and only actual time will be shown on display (the colon symbol will not be flashing) and the buttons will be functionless. The activation of the buttons you can make by pressing the button. When the sign dObI will be permanently shown on display, it is not possible to make any settings on TS10 without connection into 230VAC If the TS10 is not in a 230V socket the showed temperature is 2 °C lower than real actual temperature
Functions of TS10
- After pushing the button you can select the following functions by pushing
- AUTO thermo-switch socket works according to the program as set
- MANU serves for manual setting of temperature ( the selection by or by buttons), the temperature should be constant up to the next change of mode.
- CLO: setting of present-day and time.
- PAr: setting of parameters (constants).
- PROG programming mode
- OFF in this mode is TS10 permanently switched off.
Proceed during programming
Before the programming itself, it is necessary to set present day, time, and parameters (constants), namely in the following way
The setting of current day and time – “ CLO “ function
- Press the button, by pressing select CLO (CLOCK) function and confirm by
- Indication of hours blinks on the display, use buttons to set required data and confirm by button.
- Use the same method for minutes and day (d:1 represents Monday, d:2 Tuesday, and d:7 Sunday)
- After the completion of the setting, press the button to return
The setting of parameters (constants) – “ PAr “ function
- Press the button, by pressing select Par (Parameters) and confirm by
- PA:r2 shows on the display,
PA:r2 economic temperature (the 17°C temperature is factory-set)
- PA:r2 shows on the display
- confirm by and with using of buttons set economic temperature and press the button to confirm
PA:r3 comfort temperature (the 23°C temperature is factory-set)
- PA:r3 shows on the display
- confirm by and with using of buttons set comfort temperature and press the button to confirm
PA:r9 Firmware version/ factory setting restoration
- PA:r9 shows on the display
- The firmware version for information only
- press button to return.
Restoring the default settings:
- Press the button, by pressing select function Par and confirm by button
- By pressing the buttons to select PA:r9, and confirm by
- Simultaneously press and buttons, and it will restore the factory settings!
Note: Use only when necessary, all saved changes will be deleted!
Programming- “ PROG “ function
- Press the button, by pressing buttons to select the PROG (PROGRAMMING) function, and confirm by
By repeated pressing of buttons select one of the following options:
- Confirm by, button. The sign 1:U1 shows on display for setting up of the first time interval
- by pressing buttons set the time of the first change (min. step of 30 min.)
- assign comfort or economic temperature to the setting time by repeated pressing of the button
- Confirm by , the display automatically shows symbol 1:U2 (the second time interval in the first day).
- Use the same procedure for the setting of further time intervals (max. 4). Leave the programming regime by pressing the button.
- Select the AUTO function, and TS10 starts to work according to the program set.
Status indication of TS10:
- AUTO (or MANU) is shown = output is switched on
- AUTO (or MANU) blinks = output is switched off
EXAMPLE of program setting
- Set on 18°C (PA:r2)
- Set on 23°C (PA:r3)
- Choose a program for the whole week d1:7(Prog)
- 17:U1 assign time 6:00 and temperature
- 17:U2 assign time 9:00 and temperature
- 17:U3 assign time 13:00 and temperature
- 17:U4 assign time 19:00 and temperature
- Leave the programming regime by pressing the button and selecting AUTO mode.
Another function
Short-term change of temperature in AUTO mode:
By simply pressing of buttons in AUTO mode, it is possible to make a short-term change in the required temperature. TS10 will maintain this temperature up to next temperature change as defined in the program.
OFF “ function:
Press the button, by pressing button select OF: F function, and confirm by button. In this way, TS10 is permanently switched off. In this mode, symbols OFF and antifreeze temperature 3°C are shown alternatively on the display. To cancel this function, press the button and select a different mode using of buttons.
Child lock:
It serves for keyboard blocking, as a protection against unauthorized handling. By simultaneous pressing of , and –buttons the keyboard is locked (buttons are inactive). Message LOC (LOCK) is shortly displayed. The function can be canceled, e.g. the keyboard unblocked, by simultaneously pressing of, the and+ buttons (the buttons are again functioning now).
Installation
- Connect TS10 in 230V/50 Hz socket.
- Program it according to instructions (register respective data in the table).
- Connect the heating body you want to regulate.
Error messages
If the following error message is shown on the display, contact immediately the manufacturer (it is dealing with a failure of the temperature sensor).
Table for registration of your programs
THERMO-SWITCH SOCKET
TS10 is a digitally switched socket for automatic regulation of electrical heating systems (direct heating bodies, towel driers, fires) in family houses, flats, and offices. Up to four-time intervals with two temperature levels can be set for each day.
Further advantages:
- different temperature program for each day
- the possibility to set 2 temperature levels
- simple control and programming
- possibility to make a short-term change in program temperature
- permanent switching off of the appliance ( OFF )
- temperature regulation at steps of 0,5°C
- well-arranged display
- back-up battery NiMH 2,4 V, for more than 100 operating hours
Specification of TS10
Heat decor
- ELEKTROBOCK CZ s.r.o.
- Blanenská 1763
- Kuřim 664 34
- Tel./fax: +420 541 230 216
- www.elbock.cz
Reference
Download manual:
Leave a Reply