GENERAL SPECIFICATIONS

NORA 270S is a wired room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economical heating/cooling.

NORA 270S AND EQUIPMENT

NORA 270S Room Thermostat

GENERAL NORA 270S Digital Room Thermostat A01

Alkaline Battery

GENERAL Life A03

Dowels and Screws                          GENERAL LIFE Therma 300S Wired Room Thermostat A02

TECHNICAL DATA

Dimensions 85mm / 125mm / 19.2mm
Operating Current 3V DC (2 x AAA alkaline battery)
Relay NO Switching Current 2A (30VDC Resistive load)
0.5A (125VAC Resistive load)
Temperature Measurement Accuracy 0.1° C
Operating Temperature Range (5° C) – (30° C)
Battery Life 1 Years (2 x AAA)
Operating Temperature (-10° C) – (+50° C)
Storage Temperature (-20° C) – (+60° C)

ROOM THERMOSTAT

Buttons Functions

GENERAL NORA 270S Digital Room Thermostat A02
1 Economy Mode
2 Temperature Adjustment (Increasing)
3 Comfort Mode
4 Heating/Cooling Modes
5 Temperature Adjustment (Decreasing)
6 ON/OFF and Setting Button

Screen Indicators

GENERAL NORA 270S Digital Room Thermostat A03
1 General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 1 Room Temperature
2 General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT-2 Set Temperature
3 General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 5 Economy Mode
4 General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 6 Comfort Mode
5 General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 7 Heating Indicator
– If the Heating Indicator is blinking, the heating unit is working.
– If the Heating Indicator is steady, the heating unit is not working.
6 General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 9 Cooling Indicator
– If the Cooling Indicator is blinking, the cooling unit is working.
– If the Cooling Indicator is steady, the cooling unit is not working.
7 General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 10 Battery Indicator

ROOM THERMOSTAT PLACEMENT

Room Thermostat needs to be placed in the room which is used most frequently. For instance; living room or lounge. Placing the Room Thermostat in a spot that have air circulation like entrance of a room or side of window should be avoided. Also anywhere close to heating/cooling units such as radiator, stove and spots which get direct sun lights would not be suitable. Room Thermostat needs to be located above the floor 150 cm height. Few trials may be made to find the most convenient spot.

GENERAL NORA 270S Digital Room Thermostat A04
GENERAL NORA 270S Digital Room Thermostat A05A
GENERAL NORA 270S Digital Room Thermostat A05B

BATTERY PLACEMENT

Before starting, power off the device connected to the Room Thermostat and make sure that the energy is cut off.

GENERAL NORA 270S Digital Room Thermostat A06

As shown in the picture, press the screwdriver forward from the space shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Then align the front part of your Room Thermostat to the back and squeeze it towards the back.

Low Battery Warning: When the “GENERAL Life Lb” icon appears on the screen, it means “low battery warning”. It is recommended to replace the batteries when this warning appears.

Warning: When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Please throw your dead batteries into the waste bin for batteries

ROOM THERMOSTAT WIRING DIAGRAM

GENERAL NORA 270S Digital Room Thermostat A07

Warning!
Operations within the heating / cooling unit or the electrical installation must be carried out by professionally qualified persons.

ROOM THERMOSTAT TEMPERATURE CALIBRATION

Temperature sensors which are used in Room Thermostats are highly sensitive. You may need to calibrate your Room Thermostat if you would like to get the same temperature values with other thermometers in your living space.

Note: Recommended tempreture calibration is “0.0 C”.

FACTORY SETTINGS RESET

You can reset your Room Thermostat to its default factory settings. This operation resets the mode temperature values, calibration setting and heating/coling modes to factory setting. To reset your Room Thermostat to factory setting:

MODE SETTINGS

There are 2 modes in the Room Thermostat. These are Comfort Mode “General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 15” and Economy Mode “General life -SOLARA- 330S -RF -DIGITAL- WIRED- ROOM- THERMOSTAT- 16”. Modes work according to the pre-set temperature values adjusted by the user.

In order to change the comfort mode temperature value;

In order to change the economy mode temperature value;

You can use the “+” and “-” buttons to use the Room Thermostat manually.

TPI ROOM THERMOSTAT WORKING LOGIC

Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI technology predict when the temperature of your home will rise above or below the set temperature and turn the heating/cooling unit on and off accordingly. This ensures that your home stays at the temperature you set without maximum deviations up and down.

Heating Mode
Your room thermostat takes the average room temperature of the last 40 seconds as a basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Thus, it ensures that the room temperature remains within a certain range.

TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC

TEMPERATURE (ºC) – – – – Desired Temperature —- TPI Room Thermostat

GENERAL NORA 270S Digital Room Thermostat A08

Cooling Mode
Your room thermostat takes the average room temperature of last 40 seconds as basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Thus, it ensures that the room temperature remains within a certain range.

TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC

TEMPERATURE (ºC) – – – – Desired Temperature —- TPI Room Thermostat

GENERAL NORA 270S Digital Room Thermostat A09

WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT

FREQUENTLY ASKED QUESTIONS

Is my Room Thermostat compatible with my heating/cooling unit?

If your heating/cooling unit has on-off connections, your Room Thermostat is compatible. You can find information about your heating/cooling unit from your heating/cooling unit operating manual or from your heating/cooling unit service.

How will I connect my Room Thermostat to the heating/cooling unit?

  • We recommend that the connection between your Room Thermostat and the Heating/Cooling unit should be made by professionally qualified persons.
  • 2×0.75 mm cable is sufficient for the Room Thermostat – heating/cooling unit connection.
  • Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of the heating/cooling unit.
  • Connect the other end of the cable pair to COM and NO inputs of the terminal inside the Wall Hanger of the Room Thermostat as shown in the “ROOM THERMOSTAT WIRING DIAGRAM” section.
  • The direction of the cable ends does not matter.

DECLARATION OF CONFORMITY

ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş. which Head Office and production site is located on Fatih Mah. 1188 Sk. No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.

Compatible Directives:

Additional Information: The mentioned product can be used with heating/cooling units with on / off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.

WARRANTY CONDITIONS

Manufacturer

Product

Reference:

DOWNLOAD MANUALS:

Generallife SOLARA 330S RF DIGITAL WIRED ROOM THERMOSTAT User Manual

OTHER MANUALS

Generallife SOLARA 330S RF WIRELESS ROOM THERMOSTAT USER MANUAL

General life SOLARA 330S RF DIGITAL WIRED ROOM THERMOSTAT User Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)