General life MITRA 220 RF DIGITAL ROOM THERMOSTAT

General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- PRO

GENERAL SPECIFICATIONS

MITRA 220 RF is a wireless room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economic heating/cooling

MITRA 220 RF AND EQUIPMENT

General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 1

TECHNICAL DATA

Room Thermostat

Dimensions 85mm / 125mm / 24mm
Operating Current 3V DC (2 x AAA alkaline battery)
Temperature Measurement

Accuracy

0.1oC
Operating Sensitivity (-2.0oC) – (+2.0oC)
Operating Temperature Range (5oC) – (30oC)
Battery Life 1 Years (2 x AAA)
Operating Temperature (-10oC) – (+50oC)
Storage Temperature (-20oC) – (+60oC)

Receiver

Dimensions 90mm / 90mm / 25mm
Operation Current 230V AC
Relay NO Switching Current 7A (240VAC – Resistive load)

10A (120VAC – Resistive load)

Storage Temperature (-20oC) – (+60oC)

ROOM THERMOSTATGeneral life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 2

RECEIVER

General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 3

RECEIVER LED DESCRIPTIONS

Constant Red Receiver has power but Receiver and Room

Thermostat are not paired.

Blinking Green Waiting for pairing signal from the

Room Thermostat.

Constant Green Receiver and Room Thermostat are paired.

Heating/cooling unit is not operating.

3 Short Orange

Blinking

Operate the heating/cooling unit signal has

reached to the Receiver.

Constant Orange Heating/cooling unit is operating.
3 Short Green

Blinking

Shut the heating/cooling unit down signal has

reached to the Receiver.

Blinking Orange Heating/Cooling unit operates in manual mode.
Blinking Red Receiver did not get any signal from the Room

Thermostat for 22 minutes or longer. Heating/cooling unit has shut down.

ROOM THERMOSTAT PLACEMENT

Room Thermostat needs to be placed in the room which is used most frequently. For instance; living room or lounge. Placing the Room Thermostat in a spot that have air circulation like entrance of a room or side of window should be avoided. Also anywhere close to heating/cooling units such as radiator, stove and spots which get direct sun lights would not be suitable. Room Thermostat needs to be located above the floor 150 cm height. Few trials may be made to find the most convenient spot

General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 4 General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 5

BATTERY PLACEMENT

General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 6

As shown in the picture above, press the screwdriver forward from the space shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Then align the front part of your Room Thermostat to the back and squeeze it towards the back.

Low Battery Warning: When the “ ” icon appears on the screen, it means “low battery warning”. It is recommended to replace the batteries when this warning appears.

Warning: When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Please throw your dead batteries into the waste bin for batteries

RECEIVER PLACEMENT
The important things to note for the Receiver placement is avoiding physical contact between the Receiver and heating/cooling unit, and protecting it against materials such as liquid, dust etc.General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 7

The devices should be placed in order to minimize the damage to the received and transmitted signals by paying attention to the following points;

RECEIVER SETUP

RECEIVER WIRING DIAGRAMGeneral life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 8

Warning!
Operations within the heating / cooling unit or the electrical installation must be carried out by professionally qualified persons

PAIRING THE ROOM THERMOSTAT AND THE RECEIVER

ROOM THERMOSTAT TEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly sensitive. You may need to calibrate your Room Thermostat if you would like to get the same temperature values with other thermometers in your living space.

Note: Recommended tempreture calibration is “0.0oC”.

ROOM THERMOSTAT HEATING / COOLING MODES
Your Room Thermostat has heating and cooling modes. In order to switch easily between heating and cooling modes:

ROOM THERMOSTAT TEMPERATURE CALIBRATION

Note: Recommended tempreture calibration is “0.0oC”.

ROOM THERMOSTAT HEATING / COOLING MODES
Your Room Thermostat has heating and cooling modes. In order to switch easily between heating and cooling modes:

ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU
Hysteresis negative factory setting of your room thermostat is -0.5°C. This value may be adjusted between “-0.1°C” and “-2.0°C”. While hysteresis negative value is -0.5°C, if the room temperature goes below 0.5°C of set temperature, your room thermostat will send a signal to your heating/cooling unit. For instance, when you set your room thermostat to 22°C, if the room temperature goes below 21.5°C, on heating mode your heating unit will start working; on cooling mode your cooling unit will stop working. In order to change the hysteresis negative setting:

FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings. This operation resets the calibration setting, heating/coling modes and hysteresis settings to factory setting. To reset your Room

Thermostat to factory setting

ROOM THERMOSTAT WORKING LOGIC

Heating Mode
Your room thermostat takes the average room temperature of last 40 seconds as basis. If the room temperature goes above the hysteresis positive temperature value you set, your Room Thermostat will stop the heating unit. If it goes below the hysteresis negative temperature value, your Room Thermostat will start the heating unit. Thus, it ensures that the room temperature remains within a certain range.General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 13

Cooling Mode
Your Room Thermostat takes the average room temperature of last 40 seconds as basis. If the room temperature goes above the hysteresis positive temperature value you set, your Room Thermostat will start the cooling unit. If it goes below the hysteresis negative temperature value, your Room Thermostat will stop the cooling unit. Thus, it ensures that the room temperature remains within a certain range.

General life- MITRA- 220 RF -DIGITAL- ROOM -THERMOSTAT- 14

Your Room Thermostat sends the last status signal to the Receiver every 10 minutes. Thus, your Room Thermostat and Receiver work synchronously. If the signal cannot reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that the connection is broken and stops the heating/cooling operation for safety reasons. Likewise, in cases where the electricity comes back after a power failure, the Receiver do not operate the heating/cooling unit until ‘operate’ signal reaches from the Room Thermostat. However, in this case, if the Room Thermostat continues to operate normally, it will continue to work properly without any need for intervention since it sends a status signal to the Receiver every 10 minutes

FREQUENTLY ASKED QUESTIONS

Is my Room Thermostat compatible with my heating/cooling unit?
If your heating / cooling unit has on-off connections, your Room Thermostat is compatible. You can find information about your heating / cooling unit from your heating / cooling unit operating manual or from your heating / cooling unit service.

How will I connect my heating/cooling unit with my Receiver?
We recommend that the connection between the Receiver and heating/cooling unit should be made by professionally qualified persons. 2×0.75 mm cable is sufficient for the Receiver – heating/cooling unit connection. Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of your heating/cooling unit. Connect the other end of the cable pair to COM and NO inputs of the terminal inside the Receiver as shown in the “RECEIVER WIRING DIAGRAM” section. The direction of the cable ends does not matter.

DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.

Compatible Directives:

Additional Information: The mentioned product can be used with heating/cooling units with on / off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval

WARRANTY CONDITIONS

Manufacturer

Product

REFERENCE

DOWNLOAD MANUALS:

Generallife MITRA 220 RF DIGITAL ROOM THERMOSTAT User Manual

General life MITRA 220 RF DIGITAL ROOM THERMOSTAT User Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)