GENERAL SPECIFICATIONS
HT300 is a wired room thermostat. The user can adjust the room thermostat with the required temperature and get more comfortable and economic heating.
- Daily and Weekly Program (7×24)
- Different Mode Options (Comfort, Economy, Holiday
- Sensitive temperature measuring
- ON/OFF Control
- Heating calibration
- Wired Connection
TECHNICAL DATA
Dimensions | 85mm / 119.5mm / 24mm |
Operating Current | 3V DC (2 x AAA alkaline battery) |
Temperature Measurement Accuracy | 0.1oC |
Operating Sensitivity | 0.5oC |
Operating Temperature Range | (5oC) – (30oC) |
Battery Life | 1 Year (2 x AAA) |
Operating Temperature | (-10oC) – (+50oC) |
Storage Temperature | (-20oC) – (+60oC) |
ROOM THERMOSTAT
Buttons Functions
1 | Weekly Program Button |
2 | Temperature Adjustment (To Increase) |
3 | Settings Button |
4 | Temperature Adjustment(To Decrease) |
5 | Mode Button |
6 | On/Off Button |
Screen Indicators
ROOM THERMOSTAT PLACEMENT
A room thermostat needs to be placed in the room which is used most frequently. For instance; the living room or lounge. Placing the room thermostat in a spot that has air circulation like the entrance of a room or the side of the window should be avoided. Also anywhere close to heating units such as radiator, stove and spots which get direct sunlight would not be a suitable place. Room thermostat needs to be located above the floor between 50 cm – 150 cm in height. Few trials may be made to find the most convenient spot
BATTERY PLACEMENT
Remove your room thermostat from the Wall hanger. Then remove the battery housing from the back side of the thermostat. Put 2 alkaline batteries into battery housing. Please be sure about the directions of batteries. Hang your thermostat on the Wall hanger after assembling the battery housing back. Change both batteries together
Warning
- When the product is not used for a long time (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
- Please throw away dead batteries to trashes which specially made for batteries.
THERMOSTAT WIRING DIAGRAM
ROOM THERMOSTAT HEATING CALIBRATION
Temperature sensors which are used in room thermostats, are highly sensitive. No other thermometers in your living area have that much sensitivity. so you may need to calibrate your room thermostat if you would like to get the same temperature degrees with other thermometers in your living space.
- When the device has ”Off ” status ”On/”Off” button needs to be pressed for 3 seconds.
- From the calibration menu which appeared, you may set to any temperature degree by pressing ”Adjustment Buttons”.This value can be arranged between ”-8oC and +8oC”
- To exit the calibration menu please press ”On/Off’ button once.
Note: Recommended temperature calibration is “0.0oC”.
KEY LOCK
- In room thermostat, there is a key lock function to avoid any unintended contact.
- In order to unlock the thermostat’s key lock ” Mode” button should be pressed for 3 seconds.If buttons on the thermostat are not touched for 10 seconds,key lock will be reactivated.
DAY AND HOUR SETTINGS
- While your thermostat is On,keep pressing the ”Settings” button for 3 seconds.
- At the first screen that appears ”Hour” part will be blinking. You may set the time with the ‘Up’ and ‘Down’ buttons.
- After set the time, the ”Settings” button needs to be pressed once. For the minute setting, the minute part will be blinking. You may set the minute with ‘Up’ and ‘Down’ buttons.
- After set the minute, the “Settings” button needs to be pressed once to set the day of the week.
- Days of every week begin with Monday so if you see 1 on the screen it means Monday is chosen. Likewise, 2 would be Tuesday, 3-Wednesday, 4-Thursday, 5-Friday, 6-Saturday and 7-Sunday.
- When the setting is done you may exit by pressing for 3 seconds to the ”Settings” button.
MODE SETTINGS
- Your room thermostat has got 5 different modes. 3 of them(Comfort, Economy and Holiday Mode) are prepared and constant modes. Other modes are manual mode and weekly program mode.
- In prepared modes, temperature degrees are based on the user’s choices which have been set in the beginning. Manual mode provides to operate the thermostat with the temperature which users required and set directly. Weekly program mode provides to keep operate the thermostat with a weekly program that user set.
- The temperature degrees of prepared modes can be changed on the ”Settings” menu.
- In order to go to the ”Settings” menu, the” Settings” button needs to be pressed for 3 seconds.
- Date and time settings would appear in the first screen, to skip it ”Settings” button should be pressed 3 times.
- Comfort Mode’s temperature degree would appear and the temperature for Comfort Mode can be adjusted by pressing ”Up” and ”Down” buttons.
- When setting is done, by pressing the ”Settings” button other modes (Economy and Holiday Mode) can be set.
- Pressing the ”Settings” button for 3 seconds again would close the ‘Settings’ screen.
- Manual mode temperature can be set by pressing the ”Up” and ”Down” buttons while on the home screen.
- When the ”Up” or ”Down” buttons are pressed thermostat will be set on Manual Mode.
- In order to change to Mode settings you may press the ”Mode” button.
PROGRAM MODE
- You can adjust the weekly operating modes of your room thermostat separately for each hour per day in favor of the weekly program.
- Weekly program mode includes 2 active modes. They are “Comfort Mode” and “Economy Mode”
- In order to arrange the weekly program ”Program Mode” button needs to be pressed for 3 seconds.
- On the screen, there will be icons for the day which want to be programmed, hours of the day and active mode. The hour which will be programmed will be blinking.
- By pressing the ”Mode” button, a chosen mode for that specific hour may be changed.
- The ”Up” and ”down” buttons would allow you to change the chosen time frame and up to the active it can be programmed.
- While setting the weekly program to change the date ”Settings” button should be pressed.
- When the weekly program is chosen on the screen or while setting the weekly program, if the hours on the screen is blinking, it means that the chosen hours set on ”Comfort” mode.
- If the hour is not blinking then chosen mode is ”Economy”mode. As for blinking hour means active current time.
- After scheduling the weekly program to register it ”Program Mode’ button needs to be pressed for 3 seconds
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.
- Brand: GENERAL Life
- Product Name: HT300
- Product Type: Digital Room Thermostat
Compatible Directives
- Radio and Telecommunications Terminal Equipment Regulation 2014/53/EU (R&TTE/RED EN 301 489-1 V2.1.1:2017, EN 300 220- 1V3.1.1:2017, EN 301 489-3 V2.1.1:2017, EN 300 220-2 V3.1.1:2017, EN 62479: 2010, EN 60730-2-9:2010, EN 60730-1:2011)
- Electromagnetic Compatibility Regulation 2014/30/EU (EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007
- Low Voltage Directive 2014/35/EU (LVD EN 60730-2-9:2010, EN 60730-1:2011)
Supplementary Information: Mentioned product can be used with combi boilers with on / off output and compatibility with the directive only covers the product. ISIPARK is not responsible for the compliance of the entire system with the directive. This declaration does not apply when changes are made to the product without obtaining our consent.
WARRANTY CONDITIONS
- Warranty starts at the delivery date of devices and equpments and warranted against manufacturing defect for 2 years.
- Devices and equipments are delivered to customers in operation. Mounting and other connections will be additional fee for service.
- Devices will maintenance and repair in our factory and should send by contracted transportation company. For out services, transportation and accommodation of service personnel are covered by customers. Overtime is added on service charge and is received as cash proceeds.
- Maintenance of devices and equipments will be in our factory. For device maintenance, the round travel fares are covered by customers.
- If devices are malfunction in warranty duration, devices will be inspected in our factory to find out whose responsibility (manufacturer or customer) and will announce to user by report.
- Devices, which malfunctioned in warranty duration and found out it is responsibility of the manufacturer, customer can demand new product or repair which all costs will be fulfilled by the manufacturer regarding to cost is not higher than device.
- After inspection of malfunction and detected that, it is customer’s fault, repair cost of the device which still in warranty duration will be customer’s responsibility.
- Customers should be aware of damages (if there is any) of product and warn manufacturer since the day warranty duration starts. If customer do not warn the manufacturer with knowledge of damage, customer lose the rights of article 6.
- Devices and equipments should be used as specified in User’s Manual if not used as specified, products are out of warranty.
- If products damaged, scratched or cracked by customer. The products will be out of warranty conditions.
- Damages/Malfunctions because of using other brand’ s and model’ s devices and equipments without knowledge of the manufacturer are out of warranty.
- Failures due to battery leakage and acidic / damp conditions and rust, oxidation and liquid contact are out of warranty.
- When the product is not used for a long time (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
- The transport damage is out of warranty. Customers can take a transportation insurance.
- Damages by virtue of grid voltage are out of warranty.
- Damages because of force majeure like flood, earthquake, fire etc. are out of warranty
- All parts of the product are under warranty of our company.
- If product breaks down and gets fixed in warranty duration, duration of maintenance adds to the warranty duration. Products repairment can’t exceed 20 work days. This duration starts when the product’s problems are reported to the seller, agency, producer or the importer if there is no service station. Consumer can report the problem by; fax, e-mail, registered and reply paid letter or a similar way. If a conflict happens, the consumer has the responsibility of proofing it. If the problem can’t be solved more than 10 days the producer or importer has to supply a similar device until end of the reparation. If the product breaks down because of material, label or mounting faults in the warranty duration, firm won’t demand label costs, changing parts or any other kind of charge for repairment.
- Despite consumers rights of maintenance;
- If the product breaks down for 4 times in a year or 6 times in warranty duration and these problems effects main purpose of the product. (starting from delivery time during warranty.),
- Exceeding the maximum repairing term,
- In the case of not existing service station, determining that repairment is not possible with the report compiled by respectively service station’s seller, dealer, agency, legation, importer or manufacturer.
- You may apply for Ministry of Custom and Trade and General Directorate of Protection of Costumers and Market Surveillance in case of the problems about certificate of warranty.
- The warranty document should be kept by customer until warranty duration is finished. If warranty is lost there will be no replacement. All maintenance and repair cost is responsibility of customer in case of warranty document lost.
Manufacturer
- Title: ISIPARK İÇ DIŞ TİC. A.Ş.
- Adsress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
- Gaziemir İzmir-TÜRKİYE
- Tel: 0 (232) 457 99 50
- Fax: 0 (232) 457 91 22
- E-Mail: [email protected]
- Authorised Signatory:
- Company Stamp:
Product
- Type: Digital Room Thermostat
- Brand: GENERAL Life
- Model: HT300
- Guarantee Period: 2 Years
- Max. Time to Repair: 20 Days
- Banderole and Serial Number
REFERENCE:
DOWNLOAD MANUALS:
Generallife HT300 Wired Room Thermostat USER MANUAL
Leave a Reply