General Life HT300 SET Wireless Room Thermostat

General Life HT300 SET Wireless Room Thermostat  PRO

USAGE OF ROOM THERMOSTAT

HT300 SET is a wireless room thermostat. The HT300 SET room thermostats are used in heating systems to keep the room temperature constant at the set temperature.

USAGE AREAS

Offices
The device can be used on combi boilers and on all on/off heating systems operating at 220V AC 7A current and voltage values.

MECHANICAL DESIGN

The device consists of 3 part:

General Life -HT300 SET- Wireless- Room -Thermostat- 1 General Life -HT300 SET- Wireless- Room -Thermostat- 2

Holder
The battery cover is attached to the plastic case. After the wall bracket is mounted in the wanted area, the plastic body is attached to the wall bracket

Screen IndicatorsGeneral Life -HT300 SET- Wireless- Room -Thermostat- 3

OPERATING PRINCIPLES

HT300 SET room thermostat specifications:

The thermostat measures the room temperature with its temperature sensor. The desired temperature value is set by turning the button to the right or left. When the room temperature rises above the set temperature value, the room thermostat sends a shutdown command to the modem. Modem Turns off the relay by receiving the command.

Digital display; The set temperature, battery life, room temperature and heating symbol are displayed. The heating symbol gives information about the operation status of the boiler. The product measures 0.1oC temperature accuracy. However, there is an operating sensitivity of 0.5oC to prevent the heating unit from starting and stopping too frequently.

The device manages the heating systems by the on-off operation algorithm. This working algorithm is shown in the following graph.General Life -HT300 SET- Wireless- Room -Thermostat- 4

FUNCTIONS

Temperature Control
The room thermostat controls the room temperature according to the set value. The on / off temperature difference of the device is 0.5oC.

Calibration
The room thermostat can be calibrated if the measuring temperature wanted to be changed. The calibration range is -8oC to + 8oC.

ORDERING
When ordering, specify both the product type and the product code, for example the HT300 SET wireless room thermostat.

ROOM THERMOSTAT INSTALLATION
Remove the room thermostat by pulling it out of the wall bracket. If you want to use your room thermostat in a fixed place, mount the dismantled wall apparatus in a room you frequently use in your living space. If you want to use your room thermostat with the table bracket, place the room thermostat on the table bracket by removing the wall bracket. For example; Like your home lounge or living room. Avoid installing the room thermostat where there is a lot of air circulation, such as door entry or window edge. Also, do not place near heating units (heating panels, fireplaces etc.) and direct sunlight areas. We recommend that the room thermostat is placed at a height of 50 cm to 150 cm from the floor. You can try a few places to find where you can place the room thermostat.General Life -HT300 SET- Wireless- Room -Thermostat- 5

BATTERY CHANGE

Remove the battery cover located on the back of your room thermostat. Insert a 3V DC (2xAAA) alkaline battery into the battery compartment. When installing batteries, make sure they are incorrect position. Place the room thermostat in the wall bracket or table bracket by closing the battery cover. Replace both batteries at the same time.

WARNING!
Please dispose of your discharged batteries in waste bin which is separated for battery wastes.

MAINTENANCE
The device is maintenance-free.

MODEM

MODEM LED LIGHT COLOR EXPLANATIONS

Green Receiver synced with thermostat and Works properly.
Green Flashing Pressed to receiver sync button and waiting for thermostat sync signal.
Red Receiver has energy but no thermostat synced.
Red Flashing Boiler shut down because of, no signal from thermostat more than 22 minutes.
Orange On Manual Mode.

MODEM PLACEMENT
The important thing to note for receiver placement is that avoiding physical contact with boiler and protecting against materials such as liquid, dust etc. You can place your receiver in boiler’s cabinet without physical contact with boiler or mount receiver to Wall.

MODEM SETUP

CONNECTION DIAGRAMGeneral Life -HT300 SET- Wireless- Room -Thermostat- 7

WARNING!
Only persons who have got Professional Competence should make operations electric wiring or boiler setup.

APPLICATION EXAMPLEGeneral Life -HT300 SET- Wireless- Room -Thermostat- 8

SYSTEM COMBINATIONGeneral Life -HT300 SET- Wireless- Room -Thermostat- 9

APPLICATION EXAMPLEGeneral Life -HT300 SET- Wireless- Room -Thermostat- 10

WARNING!

SYNC ROOM THERMOSTAT AND RECEIVER

ROOM THERMOSTAT HEATING CALIBRATION

Note: Recommended tempreture calibration is “0.0oC

KEY LOCK
In room thermostat there is a key lock function to avoid any unintended contact. In order to unlock the thermostat’s key lock ” Mode” button should be pressed for 3 seconds.If buttons on thermostat are not touched for 10 seconds,key lock will be reactivated

DAY AND HOUR SETTINGS

MODE SETTTINGSGeneral Life -HT300 SET- Wireless- Room -Thermostat- 11

Your room thermostat has got 5 different modes. 3 of them(Comfort,Economy and Holiday Mode) are prepared and constant modes.Other modes are manual mode and weekly program mode. In prepared modes , temperature degrees are based on user’s choices which has been set in the beginning. Manual mode provides to operate the thermostat with temperature which user’s required and set directly. Weekly program mode provides to keep operate the thermostat with weekly program which user’s set.

WEEKLY PROGRAM
You can adjust the weekly operating modes of your room thermostat seperately for each hours per day under favour of weekly program. Weekly program mode includes 2 active modes. They are “Comfort Mode” and “Economy Mode”

TECHNICAL DATA

Room Thermostat

Power Supply
Operating Current 3V DC (2 x AAA alkaline battery)
Battery Life 1 Years (2 x AAA)
Operational Data
Temperature Measurement Accuracy 0.1oC
Operating Sensitivity 0.5oC
Operating Temperature Range (5oC) – (30oC)
Environmental Conditions
Operating Temperature (0oC) – (+45oC)
Storage Temperature (-10oC) – (+50oC)
Transport Temperature (-10oC) – (+50oC)
Standards
Radio and Telecommunications Terminal Equipment Regulation 2014/53/EU (R&TTE/RED EN 301 489-1 V2.1.1:2017,

EN 300 220-1 V3.1.1:2017, EN 301 489-3 V2.1.1:2017,

EN 300 220-2 V3.1.1:2017, EN 62479: 2010,

EN 60730-2-9:2010, EN 60730-1:2011)

Electromagnetic Compatibility Regulation 2014/30/EU (EMC EN 61000-6-3: 2007 + A1: 2011,

EN 61000-6-1: 2007

Low Voltage Directive 2014/35/EU (LVD EN 60730-2-9:2010, EN 60730-1:2011)
General Data
Weight (including package) 435 g
Color White
Material ABS, PC

Modem

Power Supply
Operation Current 220V AC
Relay NO Switching Current 7A (220V AC)
Environmental Conditions
Operating Temperature (0oC) – (+45oC)
Storage Temperature (-10oC) – (+50oC)
Transport Temperature (-10oC) – (+50oC)
General Data
Color White
Material ABS

DIMENSIONS

General Life -HT300 SET- Wireless- Room -Thermostat- 12 General Life -HT300 SET- Wireless- Room -Thermostat- 13

REFERENCE:

DOWNLOAD MANUALS:

Generallife HT300 SET Wireless Room Thermostat User Manual

OTHER MANUAL:

Generallife HT300 SET Wireless Room Thermostat DATA SHEET

General life HT300 SET Wireless Room Thermostat User Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)