Flomasta-4718G-Programmable-Thermostat-featured

Flomasta 4718G Programmable Thermostat User Manual

Flomasta

Flomasta 4718G Programmable Thermostat 

Flomasta-4718G-Programmable-Thermostat 

Terminal block connectionsFlomasta-4718G-Programmable-Thermostat-fig-1

Specification

  1. Temperature measurement: 0.0 – 40°C(0.1°C/step)
  2. Accuracy: ± 0.5°C
  3. Temperature control range: 5.0 – 35.0°C (0.5°C/step)
  4. Terminals: 2.5mm2 cable
  5. Electronic control: Type 2.B action
  6. Transmitter—Battery: 2 x 1.5V AAA alkaline battery
  7. Receiver—Input voltage: 240Vac
  8. Receiver—Output voltage: 24..240Vac 50/60Hz 10(3)A max
  9. Operating temperature: 0 – 50°C
  10. Storage temperature: -10 – 60°C
  11. Sensing Element: NTC thermistor
  12. Pollution Degree: 2
  13. Software class rating: A
  14. Rated impulse voltage: 4000V
  15. Radio Frequency: 868MHz

4718G Programmable Thermostat

  1. The system includes one wireless thermostat controller plus one RF receiver.
  2. Transmits up to 20 meter indoor.
  3. Communicates at 868MHz(Europe Standard) and designed for unlicensed operation under FCC Part 15.

Warning:

  1. If there is a dead zone in the RF communication. That means the receiver may not be able to receive the message from the transmitter. Before installation, check the communication first. If the communication fails, relocate the receiver and transmitter location.
  2. If the receiver has interference, set another transmitter address. Reset the transmitter and follow the set up instruction to reset the receiver.
  3. It is recommended locate at least 30cm away from any metal objects (including the metal box) and at least 2 meter from any electronic devices e.g. radio TV, PC, etc. The metal objects or electronic devices can interfere with the RF communication.
  4. Do not mount onto metal wall boxes.

Installation, Mounting

Warning:

  • Switch off the thermostat and any connected elec tric sources be fore installing or performing maintenance.
  • This product is for fixed wiring only.
  • Must be wired in accordance with IET regulation.

Installation Location

The thermostat (Receiver and Transmitter) should be mounted on an inner wall 1.5m above the floor in a position where it is readily affected by changes of the general room temperature with freely circulating air.
Prevent direct exposure to sunlight; dripping or splashing area. Do not place this unit at a location where air circulation is low, or where it has great temperature changes (e.g. near door).

Jumper selection

Delay / No Delay jumper:

Heater Cooler

  • No delay 10sec 4mins
  • Delay 4mins 4mins

Choose the Delay option if compressor heat is connected.

12-hours / 24-hours mode jumper:
When the 12-hours option is selected, the time is shown in 12-hours mode. Otherwise, the time is shown in 24-hours mode.

Heater / Cooler jumper:
Select the heater option when a heater is connected to the receiver. Select the cooler option when a cooler is connected to the receiver.

Address setting

In the transmitter and receiver, there are dip switches to select the addresses. The receiver ignores messages which are sent by a transmitter with a different address setting.

Permanent Override Mode

The room temperature will be maintained at the Override temperature until Override mode is released. Press <PRG> to release the Permanent Override mode.

Control Off / Sleep mode:

  1. Press the Flomasta-4718G-Programmable-Thermostat-fig-2to select the sleep mode and control off mode.
    The sequence is as below:
    Normal Mode Flomasta-4718G-Programmable-Thermostat-fig-13 Sleep ModeFlomasta-4718G-Programmable-Thermostat-fig-13Control Off ModeFlomasta-4718G-Programmable-Thermostat-fig-13Normal Mode Flomasta-4718G-Programmable-Thermostat-fig-13
  2. Press any other keys to exit the control off / sleep mode
    and return to normal mode.

Sleep Mode:
At sleep mode, < > icon is displayed. Transmitter stops measuring and displaying the temperature.

Control Off mode:
The LCD is fully turned off. The heater/ cooler is switched off, irrespective of the current control temperature setting. Do not place the thermostat near heat/cool generating
sources.

Wiring

Warning: Turn off the electrical devices and receiver before wiring.

There is 4-wire cable provided

Color Connection
Brown 230Vac Live
Blue 230Vac Neutral
Black Common
Grey Control (Call for Heat)

It is recommended that a 10A fuse is fitted at grey wire. (Please refer to the wiring diagram on the last page.

Mounting

  • Mount the Transmitter on a suitable wall/ surface using the slots and screws provided.
  • Find an optimum location to mount the Receiver.
  • Cut a hole into the wall and feed the heating/cooling control wires through to the thermostat side.
  • Using a suitable screwdriver remove the cover of the receiver by pressing in the two tabs located on both sides of the receiver.
  • Attach the receiver to the wall/ surface using the slots and screws provided.
  • Attach the wires to the receiver (see wiring section)
  • Place the cover back onto the receiver.
    Note: Please do not use the key/slots for Permanent Installation

Battery Installation

Warning: Turn off the electrical devices and disconnect the supply to the appliances before replacing the batteries. Replace only with the same or equivalent type of batteries. Do not dispose of the used batteries with household waste. Refer to your local area for the proper disposal.

  1. Pull out the battery drawer
  2. Place in the new batteries according to the marking on the battery drawer.

Selecting the Temporary/ Permanent Override Mode

  1. PressFlomasta-4718G-Programmable-Thermostat-fig-4to change the mode from normal to Temporary Override. Flomasta-4718G-Programmable-Thermostat-fig-5icon will be displayed.
  2. PressFlomasta-4718G-Programmable-Thermostat-fig-4again, the mode changes from Temporary Override to Permanent Override mode. Flomasta-4718G-Programmable-Thermostat-fig-6icon will be displayed.
  3. PressFlomasta-4718G-Programmable-Thermostat-fig-4once, the mode changes from Permanent Override to normal mode.

Review and adjust the Override temperature:

  1. Press Flomasta-4718G-Programmable-Thermostat-fig-7the Override temperature is shown.
  2. Hold theFlomasta-4718G-Programmable-Thermostat-fig-7for 2 seconds, the Override temperature will flash.
  3. PressFlomasta-4718G-Programmable-Thermostat-fig-7to adjust the Override temperature.
  4. Press Flomasta-4718G-Programmable-Thermostat-fig-8 to exit the Override temperature setting. Or transmitter will auto-return to normal mode after 10 seconds.

Temporary Override Mode:
Temporary Override mode maintains until next program time is met.

change the hour setting.

  1. Press <PRG>, the minutes will flash, press Flomasta-4718G-Programmable-Thermostat-fig-7to change the minutes setting.
  2. Press <PRG>, temperature will flash, pressFlomasta-4718G-Programmable-Thermostat-fig-7to change the set point.
  3. Press <PRG> to set the next program.
  4. The program setting sequence is as below:
    Mon~Fri (P1Flomasta-4718G-Programmable-Thermostat-fig-13P2Flomasta-4718G-Programmable-Thermostat-fig-13P3 Flomasta-4718G-Programmable-Thermostat-fig-13 P4Flomasta-4718G-Programmable-Thermostat-fig-13P5Flomasta-4718G-Programmable-Thermostat-fig-13P6)Flomasta-4718G-Programmable-Thermostat-fig-13 Sat (P1Flomasta-4718G-Programmable-Thermostat-fig-13 P2Flomasta-4718G-Programmable-Thermostat-fig-13 P3Flomasta-4718G-Programmable-Thermostat-fig-13 P4Flomasta-4718G-Programmable-Thermostat-fig-13P5Flomasta-4718G-Programmable-Thermostat-fig-13P6)Flomasta-4718G-Programmable-Thermostat-fig-13 Sun (P1Flomasta-4718G-Programmable-Thermostat-fig-13 P2Flomasta-4718G-Programmable-Thermostat-fig-13 P3Flomasta-4718G-Programmable-Thermostat-fig-13 P4Flomasta-4718G-Programmable-Thermostat-fig-13P5Flomasta-4718G-Programmable-Thermostat-fig-13P6)Flomasta-4718G-Programmable-Thermostat-fig-13
  5. PressFlomasta-4718G-Programmable-Thermostat-fig-8to exit the program setting mode and return to the normal mode. Or transmitter will auto-return to normal mode after 10 seconds.

Temporary / Permanent Override Mode:

  1. There are two modes in the override mode (Temporary override and Permanent override mode).
    The sequence is as below:
  2. NormalFlomasta-4718G-Programmable-Thermostat-fig-13Temporary Override Flomasta-4718G-Programmable-Thermostat-fig-13 Permanent OverrideFlomasta-4718G-Programmable-Thermostat-fig-13 NormalFlomasta-4718G-Programmable-Thermostat-fig-13
  3. Slide the battery drawer back to its position.
  4. Check if the thermostat works properly or not. Press “Reset” if necessary.

Start/Reset:

  1. After wiring and mounting, switch off all the connected devices. Place 2 new AAA 1.5V alkaline batteries according to the polarities marked. LCD display will be switched on.
  2. Press ‘RST’ to reset. The thermostat will be ready to control the heater / cooler .

Normal Time Mode:

  1. Temperature detection starts and LCD displays the room temperature.
  2. If Battery is LOW, Flomasta-4718G-Programmable-Thermostat-fig-9will be flashing. The old batteries must be replaced with new ones immediately.
  3. Defrost function is activated with Flomasta-4718G-Programmable-Thermostat-fig-10displayed when temperature is 5°C or below. Output will be forced to ON @ Heat & OFF @ Cool.
  4. Below 0°C, transmitter will display LO.
  5. Above 40°C, transmitter will display HI.

Normal Time Setting Mode:

  1. Press Flomasta-4718G-Programmable-Thermostat-fig-11, the Day of Week (1-7) will flash, press Flomasta-4718G-Programmable-Thermostat-fig-7 to select the current Day of Week.
  2. Press Flomasta-4718G-Programmable-Thermostat-fig-11, the Hour will flash, pressFlomasta-4718G-Programmable-Thermostat-fig-7to set the Hour.
  3. Press Flomasta-4718G-Programmable-Thermostat-fig-11, the Minute will flash, pressFlomasta-4718G-Programmable-Thermostat-fig-7to set the Minute.
  4. PressFlomasta-4718G-Programmable-Thermostat-fig-11display will jump back to the step 1.
  5. Press Flomasta-4718G-Programmable-Thermostat-fig-8 to confirm the settings and return to Normal Mode. (transmitter will auto-return to normal mode after 10 seconds.)

Factory Defined Programs:

The heater/cooler turns on according to the activated program and the control temperature setting. When the heater/cooler is On. Program number and Flomasta-4718G-Programmable-Thermostat-fig-12 icons are shown. The pre-defined programs are as below:

Heater mode:

Mon ~ Fri Sat Sun
P1 06:00 (21°C) 08:00 (21°C) 08:00 (21°C)
P2 08:00 (16°C) 10:00 (16°C) 10:00 (16°C)
P3 12:00 (21°C) 12:00 (21°C) 12:00 (21°C)
P4 15:00 (16°C) 15:00 (16°C) 15:00 (16°C)
P5 18:00 (21°C) 18:00 (21°C) 18:00 (21°C)
P6 22:00 (16°C) 23:00 (16°C) 23:00 (16°C)

Cooler mode:

Mon ~ Fri Sat Sun
P1 06:00 (24°C) 08:00 (24°C) 08:00 (24°C)
P2 08:00 (29.5°C) 10:00 (29.5°C) 10:00 (29.5°C)
P3 12:00 (24°C) 12:00 (24°C) 12:00 (24°C)
P4 15:00 (29.5°C) 15:00 (29.5°C) 15:00 (29.5°C)
P5 18:00 (24°C) 18:00 (24°C) 18:00 (24°C)
P6 22:00 (29.5°C) 23:00 (29.5°C) 23:00 (29.5°C)

Set Program:
Press <PRG>, the hour will flash, pressFlomasta-4718G-Programmable-Thermostat-fig-7to

Reference

Download manual: 

Flomasta 4718G Programmable Thermostat User Manual

Flomasta

Flomasta 4718G Programmable Thermostat User Manual

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *