INTRODUCTION

Weekly circulation digital programming thermostat with LCD touch screen, which has 6 events every day. Manual mode and program mode could be selec- ted. The thermostat is recommended for control of electric heating devices or on/off valve actuators used in hydronic floor heating.

SELECTION TABLE

ezheat T2910w TOUCHSCREEN PROGRAMMABLE Thermostat 11

Parameter:

  • Voltage:220V/230V
  • Power comsuption:2W
  • Setting range:5-90°C (can adjust to 35-90°C)
  • Limitation setting:5…60°C
  • (Factory setting:35°C)
  • Switch differential:0.5-10Cadjustable
  • factory setting1°C
  • Ambient temperature:-5-50°C
  • Protective housing: IP20
  • Housing material: anti-flammable PC

User operation

  •  On/Off ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -1
  •  At clock-controlled program mode, press” A “or” Enter to temporary control.
  • UP” ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -32 “, DOWN” ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -33” to adjust the temperature value.
  • Press the clock “ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -3 “key for 5 seconds, then enter to clock set, and choose a modified item by pressing the clock”
  • UP/DOWN”  ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -1” to modify the date and clock, then switch off to quit.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -3 “press
  •  Press the menu” ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -4 ” to choose a manual mode or program mode.
  • Set temperature and clock display alternately, room temperature can be read out directly.
  • Press both “ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -1 “for five seconds to engage the disengage key-lock function key-łock shows” ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -5 (“a “this symbol disappeared that shows unlock)

FUNCTION

  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -6Manual mode
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -2Clock-controlled program mode
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -8Heating on
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -9Wake-up, event 1
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -10Leave(am), event 2
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -11Return(am),event 3
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -12Leave (pm), event 4
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -13Return (pm), event 5
  • ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -14Sleep, event 6

PROGRAMMINGezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -34

Note:

  •  The pre-programmed setpoint(15°C) for event 384 is the same as event 2, please reset it according to your individual requirement.
  • Symbol “OFF” will be displayed if the setpoint reaches the minimum set value and the thermostat is switched off in this event.

Advanced setting(qualified person preferred):

  • Usually finished at the mounting thermostat.
  • Press [ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -4 key simultaneously press the power on key when in power off.

ADJ: Temperature calibration

  • Press + or – key to adjust the present checked value, adjustable scale:9.9 C.
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -15

SEN: Sensor mode

  • Press the + or -key to choose the senor working mode
  • IN: built-in, OUT: floor sensor.
  • ALL: both sensors, door sensor is the limit sensor
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -16

LIT: Modify limitation value

  • Press + or – key to modify the temp.
  • Limit value limitation range:5-60C
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -17

LIT: Modify limitation value

  • Press + or- key to modify the temp.
  • Limit value limitation range:5-60C
  • Re-press menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -18

DIF: Switch differential seting

  • Press + or- key to change switch differential
  • Setting range:0.5-1 0C.
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -19

LTP: Start anti-frozen function in power off

  • Press + or -key to change the present anti-frozen function
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -19

PRG: Set day off mode

  • Press + or- to choose a day off
  • 5/2-day mode, 6/1-day mode, 7-day mode
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -20

RLE: Potential-free output and main

  • power output in the same/different way.
  • Press + or-key to change the present
  • linkage state.
  • 00:in same way, 01:in defferent way
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -21

DLY: Delay time of potential-free output

  • Press +or-key to change linkage delay time
  • Range:0-5min.
  • Re-presS menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -22

HIT.Max. Temperature setting

  • Press + or – key to change the Max.value
  • Range:35-90°C
  • Re-press the menu key to enter to next step.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -23

AFAC: Reset to factory seting

  • Press + key for 5seconds still showing —
  • Reset to factory setting
  • Switch off for saving settingezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -24

Sensor Failure
Built-in sensor short-circuited or disconnected. E1:Exernal sensor is short-circuited or disconnected. When shows E0/E1 error, the thermostat must be checked till the error is eliminated

DISPLAY SYMBOLSezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -25

DIMENSIONezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -26

Mounting steps:  

  • Release the front cover by inserting a screwdriver into bottom crack.

    ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -27

  • Take the backing plate apart according to the following diagram.

    ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -28

  • Mounted the backing plate in the wall socket by screwdriver.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -29
  • After connect wires(see right diagram), the thermostat mounted on the backing plate and remounted the cover and frame.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -30

Connecting Diagram

The thermostat which connect the electric healing dev-ice is applied to full load(3200W) heating cable in 2500m height above sea level, and the rated power of external load should be less than or equal to 80%rated power thermostal when in the 2500m to 4200m height.ezheat- T2910w -TOUCHSCREEN -PROGRAMMABLE -Thermostat -31

REFERENCE:

DOWNLOAD MANUALS:

ezheat T2910w TOUCHSCREEN PROGRAMMABLE Thermostat INSTRUCTION MANUAL

EZHEAT LOGO

ezheat T2910w TOUCHSCREEN PROGRAMMABLE Thermostat INSTRUCTION MANUAL

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *