Emmeti-Zona-Smart-Thermostat-featured

Emmeti Zona Smart Thermostat Operating Instructions

Emmeti logo

Emmeti Zona Smart Thermostat 

Emmeti-Zona-Smart-Thermostat-product

Getting to know your ZONA Thermostat

Emmeti-Zona-Smart-Thermostat-fig-1

Turning your ZONA ON/OFF

  • While OFF, your ZONA will not perform any of its functions.
  • Hold Emmeti-Zona-Smart-Thermostat-fig-2for 3 seconds to turn the ZONA on or off.
  • PLEASE NOTE: Low-Temperature Protection (Frost Protection) will also be inactive

Setting the Time and Date

  • HoldEmmeti-Zona-Smart-Thermostat-fig-3 for 3 seconds.
  • The format for entering the date is YY/MM/DD.
  • UseEmmeti-Zona-Smart-Thermostat-fig-4 &Emmeti-Zona-Smart-Thermostat-fig-5 to change the Year, andEmmeti-Zona-Smart-Thermostat-fig-2 to confirm and move to the Month.
  • Repeat these steps to set the Date, Day, and Time, then pressEmmeti-Zona-Smart-Thermostat-fig-3 to finish setting and return to the main display.

Programming Modes

  • 7 Day (07) – This mode allows you to program all 7 days of the week individually.
  • 5 Day & 2 Day (52) – This mode allows you to program Monday to Friday, and Saturday to Sunday individually.
  • 24hr (24) – This mode allows you to create a single program that will repeat on a daily basis.

Select the Programming Mode

  • Hold Emmeti-Zona-Smart-Thermostat-fig-2& Emmeti-Zona-Smart-Thermostat-fig-3together for 3 seconds to enter the programming function.
  • UsingEmmeti-Zona-Smart-Thermostat-fig-2the &, select the required Programming Mode. Use Emmeti-Zona-Smart-Thermostat-fig-4toEmmeti-Zona-Smart-Thermostat-fig-5 confirm your selection

Programming Logic
When programming this thermostat you will be asked to enter a time and then the temperature you require at that time. You can set 4 time/ temperature switches throughout a single day.
E.g. 07:00 & 22°C > 10:00 & 18°C > 15:00 & 22°C > 22:00 & 18°C With these temperature settings, the heating will be increased to 22°C by 07:00 and maintain that temperature until 10:00 when the temperature requirement will switch to 18°C. This new temperature will be maintained until 22°C is required at 15:00, and 22°C will be maintained until 22:00 when only 18°C Description simplified for clarity. Building, heat up & cool down rates are not explained here and will vary according to various external parameters.

Emmeti-Zona-Smart-Thermostat-fig-6

To Enter the Programme Parameters

  • Hold Emmeti-Zona-Smart-Thermostat-fig-2& together Emmeti-Zona-Smart-Thermostat-fig-3for 3 seconds to enter the programming function.
  • Use Emmeti-Zona-Smart-Thermostat-fig-2this to confirm your selection.
  • The time display will be flashing – useEmmeti-Zona-Smart-Thermostat-fig-4 & Emmeti-Zona-Smart-Thermostat-fig-5to change the hours and pressEmmeti-Zona-Smart-Thermostat-fig-2 to confirm. Repeat for the minutes.
  • The temperature display will now be flashing – use Emmeti-Zona-Smart-Thermostat-fig-4& Emmeti-Zona-Smart-Thermostat-fig-5to select the desired temperature and press Emmeti-Zona-Smart-Thermostat-fig-2to confirm.
  • Repeat these steps for the remainder of that day, then as necessary depending on your programming mode after that.

Manual Override

Manual Override allows you to set a temperature (higher or lower) than the current room temperature by interrupting the current program. This new temperature will be maintained until the Manual Override is turned off. From the main display, briefly press Emmeti-Zona-Smart-Thermostat-fig-4either Emmeti-Zona-Smart-Thermostat-fig-5or , the Manual Emmeti-Zona-Smart-Thermostat-fig-7symbol will appear and the temperature can then be changed to the desired temperature.

  • PressEmmeti-Zona-Smart-Thermostat-fig-3 to confirm your selection.
  • To cancel the Manual Override pressEmmeti-Zona-Smart-Thermostat-fig-2. The Manual Override will be removed, press Emmeti-Zona-Smart-Thermostat-fig-3to return to the main display.
  • The ZONA will resume the previously set program.

Locking and Unlocking your ZONA
Locking the ZONA disables all the functions of the buttons and shows the small padlock symbol in the top right of the display. Hold Emmeti-Zona-Smart-Thermostat-fig-2& Emmeti-Zona-Smart-Thermostat-fig-5together for 3 seconds. The padlock symbol will appear, indicating that the ZONA has been locked. Repeat these steps to unlock the ZONA.

Advanced Settings List

  1. Boost Setting – Hours and Target Temperature 5-35°C
  2. Holiday Setting – Days and Target Temperature 5-35°C
  3. Sensor Type – 00 Inner Sensor, 01 External Sensor,
    02 Inner & External Sensor, Default 00
  4. High-Temperature Protection – 35-90°C, Default 90°C
  5. Low-Temperature Protection (Frost Protection) –
    0-10°C, Default 5°C
  6. Swing – 1-9°C, Default 1°C
  7. Temperature Calibration ADJ – ±9°C, Default 0°C
  8. Highest Target Temperature – 35-90°C, Default 35°C
  9. Lowest Target Temperature – 0-30°C, Default 5°C
  10. Home Mode – Temperature Setting 5-25°C, Default 22°C
  11.  Away Mode – Temperature Setting 5-25°C, Default 15°C
  12. Sleep Mode – Temperature Setting 5-25°C, Default 18°C
  13. Restart Thermostat / Reset Thermostat
    • The screen shows ‘ ’
    •  PressEmmeti-Zona-Smart-Thermostat-fig-4 andEmmeti-Zona-Smart-Thermostat-fig-5 the screen will change to ‘ ’
    • Wait 10 seconds or press Emmeti-Zona-Smart-Thermostat-fig-3the button to confirm setting

Advanced Settings

From here you can access the Advanced Settings for your ZONA. These settings will allow you to personalize the way your ZONA works.
To access the Advanced Setting Menu:

  • Hold Emmeti-Zona-Smart-Thermostat-fig-4& Emmeti-Zona-Smart-Thermostat-fig-5together for 3 seconds.
  • UseEmmeti-Zona-Smart-Thermostat-fig-2 to switch between the Advanced Settings. Use Emmeti-Zona-Smart-Thermostat-fig-4&Emmeti-Zona-Smart-Thermostat-fig-5 to make changes to the chosen Advanced Setting.
  • Once you have finished altering the Advanced Settings, pressEmmeti-Zona-Smart-Thermostat-fig-3 to confirm changes and return to the main display.

Connecting your ZONA to the ZONA App

Search your App Store for EMMETI ZONA and download
Creating an Account by Email, or Phone

Emmeti-Zona-Smart-Thermostat-fig-10

  • If you are setting up the App for the first time you will need to register your details. After registering you can simply log in with these details, should you log out from the App.
  • Accept the Privacy Policy to proceed.
  • Accept the Privacy Policy to proceed.
  • A unique code will be sent to your email address which you will then enter on the following screen.Emmeti-Zona-Smart-Thermostat-fig-11

Once you have created an Account
Creating a Family on the ZONA App

Emmeti-Zona-Smart-Thermostat-fig-12

Once you have created an Account (continued)

Emmeti-Zona-Smart-Thermostat-fig-13
Connecting your ZONA Thermostat(s) to the App (continued)

Emmeti-Zona-Smart-Thermostat-fig-14

  • The App will pick up your home network, or you can change it if required.
  • It may take a few minutes to connect to your ZONA and complete the pairing.
  • When the thermostat and App have paired, the Cloud symbol will appear on the display of the thermostat.Emmeti-Zona-Smart-Thermostat-fig-15

Entering the Programme Parameters on the App

Emmeti-Zona-Smart-Thermostat-fig-15Emmeti-Zona-Smart-Thermostat-fig-17

Locking/Unlocking the Thermostat via the App

Emmeti-Zona-Smart-Thermostat-fig-18

Turning the Thermostat OFF/ON via the App

Emmeti-Zona-Smart-Thermostat-fig-19

Advanced Modes

Emmeti-Zona-Smart-Thermostat-fig-20

Your ZONA thermostat can be set on 6 different modes as shown below:

Wiring Diagram

Emmeti-Zona-Smart-Thermostat-fig-21

  • 6 Tannery Yard
  • Witney Street
  • Burford
  • Oxfordshire
  • OX18 4DQ
  • T: +44 (0) 1993 824900
  • F: +44 (0) 1993 824990
  • E: [email protected]

REFERENCE:

DOWNLOAD MANUALS:

Emmeti Zona Smart Thermostat Operating Instructions

Emmeti logo

Emmeti Zona Smart Thermostat Operating Instructions


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *