Single Stage / Heat Pump Applications

  • Non-Programmable,
  • Programmable 5+1+1
  • Day or 24-Hour
  • Dual Powered – Hardwired or Battery Powered

PROGRAMMABLE MODELSEmerson-1F82-0261-Blue-Series-Thermostat-1 Emerson-1F82-0261-Blue-Series-Thermostat-2

  • Easy-to-Read 2-Square-Inch Blue™ Display
  • Exclusive – Easy Push-Connect Color-Coded Terminals
  • All Models are Dual Powered

Exclusive 2″ Blue™ Features

  • 2-square-inch Blue™ display with easy-to-see characters
  • Exclusive Cool Savings™ feature saves energy during peak A/C demand periods
  • Long battery life – uses 2 “AA” alkaline batteries (included)
  • Exclusive battery power monitor
  • 5-year warrantyEmerson-1F82-0261-Blue-Series-Thermostat-3

Programmable Models

  • Choice of programmable models in 5/1/1 day or 24-hour programmable models 4 time and 4 temperature settings per program (heat & cool)
  • Energy savings up to 33%
  • Patented pre-programmed software simplifies time and temperature programming

Display

  • Easy-to-read LCD with improved contrast
  • Lighted display for easier
  • low-light viewing

Comfort & Convenience
Permanent program retention during power loss Setpoint Hold
Simple “setup” menu to activate optional features Temporary temperature override two-hour minimum or until next program period (1F82-0261, 1F80-0261, 1F80-0224) Soft-touch keypad
Display temperature recalibration (+/- 4°)
Easy access battery compartment

Performance

  • Dual-Powered…choice of battery-powered or hardwired, for all applications
  • Selectable Energy Management Recovery (1F82-0261, 1F80-0261, 1F80-0224)
  • Fast (FA) or slow (SL) heating cycle anticipation
  • Easy-to-wire push-connect color coded terminals
  • Compressor lockout protection
  • Millivolt compatible
  • Electric heat option

Dimensions
4.8″W x 3.8″H x 1.5″D

Specifications

Electrical Specifications

Rating

  • 0 to 30 VAC, 50/60 Hz or DC
  • 0.05 to 1.5 Amps (load per terminal)
  • 1.5 Amps maximum load (all terminals combined)
  • Standard Systems
  • Gas, Oil, Electric
  • Single Stage/Heat Pump
  • Millivolt Systems

Thermal Specifications

  • Setpoint Temperature Range: 45° to 90° F (7° to 32° C)
  • Blue™ 2″ Series Rated Differential: 0.6° to 1.7° F with adjustable anticipation
  • Operating Ambient Temperature: 32° to 105° F (0° to 40° C)
  • Operating Humidity Range: 90% non-condensing maximum
  • Shipping Temperature Range: -40° to 150° F (-40° to 65° C)

Accessories

Wall Plate F61-2634 (6.5″W x 5″H)
Thermostat Guard F29-0231
(For additional guard options refer to White-Rodgers catalog at www.white-rodgers.com)

For Additional Information Visit www.white-rodgers.com

Emerson-1F82-0261-Blue-Series-Thermostat-4

B, H =Battery or Hardwired ** Recommended Battery Change Interval Is Once per Year *** Optional Continuous Display Light w/Hardwire Connection

St. Louis, Missouri Markham, Ontario
314-553-3600 905-948-3411
www.white-rodgers.com
www.emerson.com

The Emerson logo is a trademark and a service mark of Emerson Electric Co.

References:

Download Manual

Emerson 1F82-0261 Blue Series Thermostat Specification Guide

Emerson

Emerson 1F82-0261 Blue Series Thermostat Specification Guide

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *