Drayton-RTS1-Thermostat-featured

Drayton RTS1 Thermostat Technical Specification Guide

drayton-logo

Drayton RTS1 Thermostat Technical

Drayton-RTS1-Thermostat-product

Room Thermostat Range
The RTS range of thermostats utilise electronic sensing to provide accurate temperature control. Six models are available to suit all domestic applications including frost protection and combi boilers.

Models

  • RTS1: Standard model
  • RTS2: With LED ‘ON’ indicator
  • RTS3: Frost thermostat
  • RTS4: Volt-free contacts (Suitable for combi boilers)
  • RTS9: Volt-free heating/cooling change over switch with call for heat LED indicator
  • RTS10: Volt-free heating/cooling change over switch with call for heat LED indicator (Min-Max)

Flexible Features

  • Range limiting stops
  • Set point locking
  • Surface or conduit box mounting
  • Double insulated

Wiring

Drayton-RTS1-Thermostat-Technical-fig.1

Getting Technical

Model:                                                                              RTS
Power supply: 230V ac 50Hz fused 3A
230V ac 50Hz fused 3A Double insulated (no earth required)
Switch rating: 2(1)A 230V a.c.
Switch type: RTS1, 2 & 3:

RTS4, 9 & 10:

S.P.S.T

S.P.D.T. Volt-free

 

Wiring:

Designed for fixed wiring only, to comply with current IET wiring regulations (BS7671).
Mounting: Suitable for surface or conduit box mounting
Ambient temperature: Operating 0ºC to 40ºC /Storage –20ºC to 55ºC
Ambient humidity (non condensing):  

Operating 25% to 90% / Storage 15% – 95%

Temperature range:

RTS1, 2 , 4 & 9:

RTS10:

RTS3 (Frost):

 

10 to 30ºC

14 to 30ºC

3 to 10ºC

Control accuracy:

RTS1, 2 , 4, 9 & 10:

RTS3:

 

<0.6ºC at 4º/hour 1ºC typical

Ball pressure test: 75ºC
Pollution degree: 2
Energy class: I = 1% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
 

Relevant directives:

2014/35/EU Low Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive

2011/65/EU RoHS Directive

Applied standards: EN60730-1; EN60730-2-9

RTS Room Thermostats

Product Part No.
RTS1 SPST contacts 24001
RTS2 SPST with LED indicator 24002
RTS3 SPST frost thermostat 24003
RTS4 SPDT volt free contacts 24004
Product Part No.
RTS9 SPDT volt free +LED 24030
RTS10 SPDT volt free +LED (Min 14ºC) 24031
RTS pattress 24022

REFERENCE:

other Manual: Drayton RTS1 Thermostat Installation instructions

drayton-logo

Drayton RTS1 Thermostat Technical Specification Guide