About Your New Thermostat

Congratulations! Your recreational vehicle manufacturer has equipped your RV with the most advanced RV thermostat. Your Dometic Single Zone LCD thermostat has been designed for ease of operation and for many years of reliable service.

Features

  • Liquid Crystal Display and Green LED Mode Indicators
  • Auto Fan
  • Indoor Temperature Display
  • °F / °C Display
  • Air conditioner can provide additional indoor air circulation during furnace operation.

To help familiarize yourself with the operation of the Single Zone LCD thermostat, review the following diagrams and accompanying text that explain the functional characteristics of this system.
Your Single Zone LCD thermostat is equipped with both a liquid crystal display (LCD) that identifies the temperature set-point, fan speed (Auto, Low, High), and F/C and green LEDs that indicate the mode of operation (Off, Fan, Cool, Furnace, Heat Pump or Heat Strip*). The modes of operation available will vary depending on the system installed in your RV.
* Select models.

System Initialization

A system initialization will need to be performed by the installer after the system is installed.

  • Make sure the Single Zone LCD thermostat is in the Off condition. See page 4, “Quick Reference To Control Buttons”.
  • Press the “+” button and, while holding it, also press and hold the On/Off Mode button for three seconds. LCD will show ― ― . Press the On/Off Mode button again to turn system off.
    This completes the initialization.

The furnace On/Off temperature differential should be set at this time. See “Mode Description – Furnace” on page 9 for further information on furnace mode differential setting.
Your Dometic Single Zone LCD thermostat has been pre-programmed. Review settings below and adjust the settings to your personal comfort level.

Factory Preset Settings
Heating 68ºF / 20ºC
Cooling 72ºF / 22ºC
Fan Speed Auto
Mode Off
Furnace Differential 2ºF

Quick Reference To Control Buttons

DOMETIC -Single -Zone -LCD-Thermostat-FIG.1

Programming & Operations

On/Off

To turn On the Single Zone LCD thermostat, press the On/Off Mode button. The LCD will be activated. To turn Off the Single Zone LCD thermostat press the On/Off Mode button and toggle through the modes until the On/Off green LED is on. The LCD will go out and the green LED will remain on for approximately 15 seconds, then go out.

Temperature Format ºF / ºC

Simultaneously press the “+” and “―“ buttons to toggle between Fahrenheit and Centigrade format. ºF indicates Fahrenheit and ºC indicates Centigrade.

DOMETIC -Single -Zone -LCD-Thermostat-FIG.2

Inside Temperature

To display the Inside Temperature, the Single Zone LCD thermostat must be in the Off Mode. Press either the “+” or “―” button to display the Inside TemperatureDOMETIC -Single -Zone -LCD-Thermostat-FIG.3

Mode Selection

Press the On/Off Mode button to advance through the available modes. Each successive press will advance to the next available mode. The green LED will indicate the mode selected. Depending on the systems installed, your choices will be Off, Fan, Cool, Furnace, Heat Pump or Heat Strip. See “Mode Description” on pages 8-10 for more information on modes.

DOMETIC -Single -Zone -LCD-Thermostat-FIG.4

Fan Speed

Press the On/Off Mode button until the fan green LED is lit. The LCD will show “Lo” (Low), “Hi” (High) or “Au” (Auto). Press the “+” or “―” button to select the desired fan speed. See “Special Features” on page 11 for more information on Auto Fan.

DOMETIC -Single -Zone -LCD-Thermostat-FIG.5

Temperature Set-Point

Press the “+” or “―” button to change the temperature set-point. The temperature set-point is indicated by two digits on the LCD. Press the “+” to increase and the “―” to decrease the temperature setpoint. The maximum set-point for the system is 90º F. The minimum set-point is determined by the active operating mode. For heating, the minimum is 40º F and minimum for cooling is 55º F.

DOMETIC -Single -Zone -LCD-Thermostat-FIG.6

Mode Description

  • “Off” – Off Mode
    When selected, the LCD will be blank and the Off green LED will turn on for 15 seconds, then it will turn off.
  • “Cool” – Cool Mode
    In the Cool mode the system will cycle the compressor On and Off based on the room air temperature and the temperature set-point on the Single Zone LCD thermostat. The fan will turn on first followed by the compressor in approximately 2 minutes. In this mode there are 3 fan speed selections:
    • Lo – (LOW): The fan operates continuously at low speed. The compressor cycles ON and OFF.
    • Hi – (HIGH): The fan operates continuously at high speed. The compressor cycles ON and OFF.
    • Au – (AUTO): When auto fan is selected the fan speed will vary depending on the difference between the temperature set-point and the room air temperature. In auto fan the compressor and the fan will cycle On and Off with the thermostat. See “Special Features” on page 11 for information on auto fan.
      “Furnace” – Furnace Mode

In this mode there are 3 fan speed selections:

  • Lo – (LOW): The fan operates continuously at low speed.
  • Hi – (HIGH): The fan operates continuously at high speed.
  • Au – (AUTO): The fan will be OFF.

Note: If additional indoor air circulation provided by the air conditioner is not desired during Furnace Mode of operation, select Au (AUTO) in the Fan Mode to shut the air conditioner fan off. If Lo (LOW) or Hi (HIGH) is selected the air conditioner fan will continue to operate on the selected speed.
In the FURNACE mode the system will cycle the RV’s furnace On and Off based on the room air temperature and the temperature set-point on the Single Zone LCD thermostat. The system can be configured to operate using an On/Off differential of either 1 degree F or 2 degree F. This feature is programmed during the system initialization. See “System Initialization” on page 3.
To set the temperature differential the system must be Off. Press the “―” button and, while holding it, also press and hold the On/Off Mode button for three seconds. Release the On/Off Mode button. Then release the “―” button. Press the “+” button to toggle between “d1” and “d2”, “d1” for 1 degree F differential and “d2” for 2 degrees F differential.

“Heat Pump” – Heat Pump Mode (Select Models)
In the Heat Pump mode the system will cycle the compressor On and Off based on the room air temperature and the temperature setpoint on the Single Zone LCD thermostat. When the system calls for heating there will be a delay of approximately two minutes. In auto fan, the compressor will turn On first followed by the fan in approximately 15 seconds. In this mode there are 3 fan speed selections:

  • Lo – (LOW): The fan operates continuously at low speed. The compressor cycles ON and OFF.
  • Hi – (HIGH): The fan operates continuously at high speed. The compressor cycles ON and OFF.
  • Au – (AUTO): When auto fan is selected the fan speed will vary depending on the difference between the temperature set-point and
    the room temperature. In auto fan the compressor and fan will cycle On and Off with the thermostat. The compressor shuts off first followed by the fan in approximately 15 seconds. See “Special Features” on page 11 for information on auto fan.

“Heat Strip” – Heat Strip Mode (Select Models)
In the Heat Strip mode the system will cycle the heat strip On and Off based on the room air temperature and the temperature setpoint on the Single Zone LCD thermostat. In this mode there are 3 fan speed selections:

  • Lo – (LOW): The fan operates continuously at low speed. The heat strip cycles On and Off.
  • Hi – (HIGH): The fan operates continuously at high speed. The heat strip cycles On and Off.
  • Au – (AUTO): The fan operates in low speed and will cycle On and Off with the thermostat.
    “Fan” – Fan Mode

In Fan mode there are 3 fan speed selections:

  • Lo – (LOW): The fan operates continuously at low speed.
  • Hi – (HIGH): The fan operates continuously at high speed.
  • Au – (AUTO): The fan will be Off.

Special Features

Auto Fan
When auto fan is selected the fan speed will vary depending on the difference between the temperature set-point and the room temperature. In auto fan the compressor and fan cycle On and Off with the thermostat.
When the difference is:

  • >5º The fan operates on HIGH
  • <4º The fan operates on LOW

Compressor Time Delay
A time delay of approximately two minutes occurs any time the compressor is required to begin the cooling or heat pump cycle.
Power Interruption
In the event the power to the air conditioner or control is interrupted, the system will restart with the previous set points once power is restored.
LCD Error Code
When the system determines that one of the faults listed below has occurred an error code will be displayed on the LCD.
Error Code:

  • E1 Loss of communication between the Single Zone LCD thermostat and the module board. LCD will cycle between E1 and the previous mode setting. The system will shut down.
  • E2 Open circuit or out-of-range Indoor Temperature Sensor. Heating and cooling operations will be locked out. Fan operation can continue to operate.
  • E3 Shorted Indoor Temperature Sensor. Heating and cooling operations will be locked out. Fan operation can continue to operate.
  • E4 Open circuit or out-of-range Outdoor Temperature Sensor (select models). Heat Pump operation will be locked out. Air Conditioner, Fan, and Furnace operation can continue to operate.
  • E5 Open circuit or out-of-range Freeze Sensor. The air conditioner’s mode of operation will be locked out. The furnace, heat strip, heat pump, and fan mode of operation can continue to operate but displays the last temperature set-point.

General Information

The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV. Some preventative measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner. During extremely high outdoor temperatures, the heat gain of the vehicle may be reduced by:

  1. Parking the RV in a shaded area.
  2. Using window shades (blinds and/or curtains).
  3. Keeping windows and doors shut or minimizing usage.
  4. Avoiding the use of heat producing appliances.

Operation on High Fan/Cooling mode will give optimum or maximum efficiency in high humidity or high outside temperatures.
Starting the air conditioner early in the morning and giving it a “head start” on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature.
For a more permanent solution to high heat gain, accessories like A&E outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening.

The manufacturer of this air conditioner will not be responsible for damage caused by condensed moisture on ceilings or other surfaces. Air contains moisture and this moisture tends to condense on cold surfaces. When air enters the RV, condensed moisture may appear on the ceiling, windows, metal parts, etc. During normal operation, this unit removes moisture from the air. Keeping doors and windows closed when this air conditioner is in operation will minimize condensed moisture on cold surfaces.

Maintenance

Air Filter – Periodic cleaning or replacement of the air conditioner/heat pump air filters is required. When a system fan run time exceeds 1000 hours the filter icon is displayed in the LCD. See “Quick reference to LCD icons” on page 3. When this occurs wash the filter with soap and warm water. Let dry and reinstall. NEVER run the air conditioner without the air filter in place. This may plug the unit evaporator coil with dirt and substantially degrade the performance of the unit. To reset the fan run time and clear the filter icon, hold the INSIDE and OUTSIDE buttons for three seconds. This will clear the fan run time for the current zone selected. Dometic CCC 2 thermostat: Clean the CCC 2 thermostat with a moist soft cloth. DO NOT spray water directly on the CCC 2 thermostat. DO NOT use solvents for cleaning.

Service

In the unlikely event the unit fails to operate or operates improperly, check the following before calling your service center.

  1. If your RV is connected to a motor generator, check to be sure the motor generator is running and producing power.
  2. If the RV is connected to a power supply by a landline, check to be sure the line is sized properly to run air conditioner load and it is plugged into the power supply.
  3. Check your 120 VAC fuse or circuit breaker to see if it is open. Insure fuse is not burnt, or circuit breaker is ”ON” and not activated.
  4. Check your 12 VDC fuse or circuit breaker to see if it is open.
  5. After the above checks, call your local service center for further help. This unit must be serviced by qualified service personnel only.
    When calling for service, always give the following:
  6. Unit Model Number and Serial Number found on the Identification Label located on the Base Pan of the unit bottom. It is necessary to remove the return air cover to expose the rating plate.
  7. Electronic Control Kit Part Number and Serial Number found on the Identification Label located on the side of the Kit. This kit is mounted in the return air cavity and can be exposed by removing the return air cover.

USA
SERVICE OFFICE Dometic, LLC 2320 Industrial Parkway Elkhart, IN 46516
574-294-2511
CANADA
Dometic, LLC 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA
519-720-9578
For Service Center Assistance Call:
800-544-4881

REVISION Form No. 3312366.010 7/10 (Replaces 3312366.000) (French 3312796.018) ©2010 Dometic, LLC Lagrange, IN 46761

REFERENCE:

Download Manual:

DOMETIC Single Zone LCD Thermostat Operating Instructions

OTHER MANUALS:

DOMETIC Single Zone LCD Thermostat User Guide

dometic-logo

DOMETIC Single Zone LCD Thermostat Operating Instructions


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *