devi logo

Devireg 550 Electronic Thermostat

Devireg-550-Electronic-Thermostat-PRODUCT

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long-lasting comfort at a minimum of environmental impact.

Basics

Safety instructions

Functional Overview

Devireg-550-Electronic-Thermostat-FIG-1

The thermostat is operated by using the button as follows

Temperature Setting

Devireg-550-Electronic-Thermostat-FIG-3

Operation without timer

Changing Battery

Operating the child lock

Switching the thermostat on and off

The thermostat can only be switched off if the timer is off. The thermostat is on by default.

Advanced

Switching the timer on and off

Devireg-550-Electronic-Thermostat-FIG-10The timer is switched on and off by pressing the button.

When the timer is on:

When the timer is off

Note

Optional Settings

Setting the time and weekday

Devireg-550-Electronic-Thermostat-FIG-12

Setting the timer

Devireg-550-Electronic-Thermostat-FIG-14

Devireg-550-Electronic-Thermostat-FIG-16

Devireg-550-Electronic-Thermostat-FIG-17

Setting minimum floor temperature

(This only applies if the thermostat is configured to use a room and floor sensor.)

Troubleshooting

Uninstalling Product

Specifications

Temperature range: +5 to +35 °C or OFF
Floor temperature limit: +20 to +50 °C
Operation voltage: 180-250 VAC, 50/60 Hz
Resistive load: 230 V ~ 16A /3680W
Inductive load: cos ϕ 0,3 = Max. 1A
Power consumption: < 500 mW
Battery back-up: 100 hours
Economy set-back: 0 to -30 °C
Offset: -5.5 to +5.5 °C
IP class: IP30
Sensing unit NTC 15 kOhm AT 25 °C

Installation overview

Safety instructions

Installation guidelines

Devireg-550-Electronic-Thermostat-FIG-19

System Overview

Three different sensor configurations

FS: Floor sensor (comfort heating)

RS: Room sensor (total heating)

RFS: Room and floor sensor (total heating)

Network

Functional Overview

Devireg-550-Electronic-Thermostat-FIG-20

The thermostat is programmed by pressing and holding the button as follows:

Seconds held Function accessed Notes
3 Time and weekday setting
6 Timer setting
9 Minimum floor temperature setting Only when configured to use room and floor sensor
12 Basic settings

Installation – step by step

Preparations and guidelines

Dismantling the thermostat

Devireg-550-Electronic-Thermostat-FIG-21

Devireg-550-Electronic-Thermostat-FIG-22

Connecting cables

Devireg-550-Electronic-Thermostat-FIG-24 Devireg-550-Electronic-Thermostat-FIG-25

Mounting and reassembling the thermostat

Devireg-550-Electronic-Thermostat-FIG-26

Activating the thermostat

Configuring basic settings

Devireg-550-Electronic-Thermostat-FIG-27

Select network status of the thermostat:

Devireg-550-Electronic-Thermostat-FIG-28

Devireg-550-Electronic-Thermostat-FIG-9Select status for adaptive function:

Devireg-550-Electronic-Thermostat-FIG-29

Devireg-550-Electronic-Thermostat-FIG-9Select the desired sensor configuration:

Devireg-550-Electronic-Thermostat-FIG-30

Notice: The floor temperature is measured where the sensor is placed. The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top. Floor manufactures often specify the max. temperature on the top surface of the floor. Please contact your floor supplier for maximum surface temperature.

Devireg-550-Electronic-Thermostat-FIG-31

Devireg-550-Electronic-Thermostat-FIG-32

Optional settings

Network setup

Devireg-550-Electronic-Thermostat-FIG-33

Trouble-Shooting Diagram

Error code Problem Solution
1 The thermostat is configured as master in the local network but has detected another master Reconfigure one of the master thermostats as slave or independent.
2 The thermostat is configured as slave in the local network but cannot detect a master Reconfigure one of the thermostats as master, or configure all units as independent.
3 The thermostat was switched off because of overheating Allow the thermostat to cool down, and then access basic settings to reset the error. Check the wiring if this error appears again. Replace the thermostat if the error does not disappear
4 Short circuit in floor sensor Check the sensor connected to the thermostat. Disconnect the sensor cables and test them. Replace

the sensor if it is faulty. Replace the thermostat if the error keeps appearing

5 Open circuit in floor sensor Check the sensor connection to the thermostat. Disconnect the sensor cables and test them. Replace

the sensor if it is faulty. Replace the thermostat if the error keeps appearing

6 The clock and weekday have not been set Set the clock and weekday. This error usually appears:
  • If the clock has not been set and the timer is activated
  • If the thermostat has been unplugged from the supply voltage for more than 4 days and the backup battery is depleted
  • If the thermostat is unplugged from the power supply, and the backup battery has not accumulated enough power (takes approx. 16 hours)

Factory Settings

Item Factory setting Options
Network type Alone (ALO) Independent (ALO) Master (MAS)

Slave (SLA)

Adaptive function On (AdAP) On (AdAP) Off (OFF)
Sensor Room + floor sensor (FS) Floor sensor (FS) Room sensor (RS)

Room + floor sensor (FS)

Max. floor temperature +35 °C +20 to +50 °C
Offset 0 °C -5.5 to +5.5 °C
Economy set-back -5 °C -1 to -30 °C
Weekday 1 1 to 7
Time Not set Normal 24 hour clock
Timer Not set Up to 336 settings/week

Warranty

The 2-Year DEVI Warranty

You have purchased a Devireg™ 550 thermostat, which forms an integrated part of a Deviheat™ system, which we are certain will improve your home comfort and economy. Deviheat™ provides complete heating solutions with Deviflex™ heating cables or Devimat™ heating mats, Devireg™ thermostats and Devifast™ fitting bands.

If, however, contrary to all expectations, a problem should occur with your heating system, we at DEVI, with manufacturing units in Denmark, are, as European Union suppliers, subject to general product liability rules, as stated in Directive 85/374/CEE, and all relevant national laws which implies that:

DEVI provides a warranty for Deviflex™ heating cables and Devimat™ heating mats for a 10 year period and all other DEVI products for a 2 year period against defects in material and production. The guarantee is granted on the condition that the WARRANTY CERTIFICATE on the overleaf is filled out properly in accordance to instructions and that the defect is inspected by, or presented to, DEVI or authorised DEVI distributor. Please note that the wording of the WARRANTY CERTIFICATE must be provided in English or local language with the ISO code for your country in the upper left corner of the front page of the installation instructions in order to release the warranty. The obligation of DEVI will be to repair or supply a new unit, free of charge to the customer, without secondary charges linked to repairing the unit.

In case of defective Devireg™ thermostats, DEVI reserves the right to repair the unit free of charge and without unreasonable delay to the customer. The DEVI warranty does not cover installations made by unauthorised electricians, or faults caused by incorrect designs supplied by others, misuse, damage caused by others, or incorrect installation or any subsequent damage that may occur. If DEVI is required to inspect or repair any defects caused by any of the above, then all work will be fully chargeable. The DEVI warranty is void, if payment of the equipment is in default. At all times, we at DEVI will respond honestly, efficiently and promptly to all queries and reasonable requests from our customers. The above-mentioned warranty concerns product liability whereas matters in relation to legislation on sale of goods shall be referred to national law.

2-YEAR WARRANTY Warranty Certificate

The DEVITM Guarantee is granted to:

Attention:

  1. Type of thermostat: …………………………
  2. Electrical installation by: …………………………
  3. Material number: …………………………
  4. Date: …………………………
  5. Suppliers Stamp: ………………….
  6. Date: ………………….

Article No: 08095121
Version: 04.01

CONTACT

DEVI A/S

Reference

Download Manual:

Devireg 550 Electronic Thermostat Installation Guide

Devireg-LOGO

Devireg 550 Electronic Thermostat Installation Guide

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)