devi logo

Devireg 530 Electronic Thermostat

Devireg-530-Electronic-Thermostat-Installation-Guide-product

Applications and Functions

Maximum floor temperature setting

Maximum floor temperature is preset at the factory to 35°C for cable temperature safety.

Warning: Local building regulations must be observed when changing the maximum preset tempera ture.You can/must set the maximum floor tempera ture on the Devireg™ 532 by taking off the front cover and with a screwdriver adjust the sunken temperature dial in the top left hand corner between 20° to 50°C.

Notice:
The floor temperature is measured where the floor sensor is placed. The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top. Floor manufactures often specify the max. temperature on the surface of the floor.Please contact your floor supplier for maximum surface temperature.

Light indications (LED)

The Devireg™ 530 series has a LED indicator above the 2 pole safety switch (see illustration).

Devireg-530-Electronic-Thermostat-Installation-Guide-fig-2

The LED has four indications:

is used for setting the thermostat in frost protection mode, i.e. keeping the room/floor temperature (depending on type of thermostat) at approx. 5°C at any time.

Installation instructions

Placement of Devireg™ 530, 531, and 532Devireg-530-Electronic-Thermostat-Installation-Guide-fig-4

Configuration – Max. floor temp

Devireg-530-Electronic-Thermostat-Installation-Guide-fig-5

Technical specifications for Devireg™ 530, 531, and 532

Operation voltage 180-250 VAC, 50/60 Hz
Standby consumption Max. 0.25W
3FMBZT:

t 3FTJTUJWF MPBE t *OEVDUJWF MPBE

 

230V ~ 15A/3450W

cos φ = 0.3 Max. 4A

Sensing unit NTC 15 kOhm at 25°C
Sensing values: t           0¡$ t         20¡$ t 50¡$  

42 kOhm

18 kOhm

6 kOhm

Hysteresis +/- 0.4°C for 530 (528)

+/- 0,2 for 531 + 32

Ambient temperature -10° to +30°C
Frost protection 5°C
Temperature range:

t 530 t 531 t 532

 

5-45°C

5-35°C

5-35°C, floor temperature limiter range: 20-50° C

Sensor failure monitoring The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or short-circuited.
IP class 31
Dimensions 85 mm x 85 mm

The 2-Year DEVI Warranty

2-YEAR WARRANTY Warranty Certificate
The DEVITM Guarantee is granted to:

Devireg-530-Electronic-Thermostat-Installation-Guide-fig-6

Attention:
The Warranty Certificate must be completed correctly for the Warranty to be valid.Please read the Warranty conditions on the previous page.Devireg-530-Electronic-Thermostat-Installation-Guide-fig-7Devireg-530-Electronic-Thermostat-Installation-Guide-fig-8

Address: DEVI A/S Ulvehavevej 61 DK-7100 Vejle
Tel: +45 74 88 85 00
Fax: +45 74 88 85 01
www.devi.com

Reference

Download Manual:

Devireg 530 Electronic Thermostat Installation Guide

devi logo

Devireg 530 Electronic Thermostat Installation Guide

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)