Delta Dore TYBOX 5000 Room Thermostat
TECHNICAL CHARACTERISTICS
- Contact output 2A (230V) – 1.C (brownout)
- Ball test: 125 ° C
- Rated surge voltage: 4000V
- Powered by 2 lithium batteries 1.5 V, LR03/AAA (supplied), 5-year life under normal use
- Class II insulation
- Radio frequency 868.7 MHz to 869.2 MHz
- Maximum wireless power: <10 mW
- Receiver category: 2
- Wireless remote control device
- Wireless range: 100 to 300 metres outside, variable depending on the associated equipment (the range can vary depending on the installation conditions and the electromagnetic environment)
- Dimensions: 80 x 84 x 21 mm
- Degree of protection: IP 20
- Wall mounting
- Installation in an environment with normal pollution levels
- Storage temperature: – 10 to +70°C
- Operating temperature: 0 to +55°C
LOCATION
Since the temperature measurement sensor is inside the box, you must install the thermostat flush-mounting box:
- on an accessible wall at a height of 1.50 m
- away from heat sources (fi replaces, sunlight) and draughts (windows, doors)
IMPORTANT: Do not install the thermostat on a wall in contact with the outdoors or with an unheated room (e.g. garage, etc.) The sleeve output in the flush mounting box must be blanked off (with mastic) in order to avoid unwanted air movements that could bias the sensor reading.
CONNECTION
The diagrams provided are simplifi ed for greater clarity. Protections and other accessories required by standards are not illustrated. – Standard NF C15-100 and good practice must be complied with. Connected or nearby units must not generate excessive interference (directive 89/336/EEC).
Circulator control
Control of the thermostat input of the boiler or heat pump (HP) no-reversible
- Remove the terminal, on the back of the device, using a screwdriver.
- Connect the terminal to the control wire (circulator, boiler or heat pump thermostat input).
- Fit the terminal back into its position.
MOUNTING
- Remove the thermostat cover by pushing the pin using a screwdriver.
- Attach the base by using suitable fixings for mounting. Fit the cover back onto the thermostat.
- Insert the batteries, with the right polarity
CONFIGURATION
This menu is used to determine all the settings adapted to your installation
- To enter configuration mode, press the MODE button for 10 seconds until the screen displays CF01.
- Press + or – to set.
- Briefly press MODE to go to the next menu. Press MODE or wait 5 seconds to exit.
CF01 – Correcting the temperature measured Setting from -5°C to +5°C
Example: If the temperature displayed by the unit is 15°C and the actual temperature (thermometer) is 16°C, set +1°C.
CF02 – Settings lock
0 | No locking (default setting) |
1 | Total locking |
2 | Partial locking. Modification of the temperature setting at +/-2°C |
The screen will display ‘____’ if it is locked To unlock (selection 1 and 2), simultaneously press + or – the buttons for 10 seconds. CF04 – Frost protection mode temperature setting Setting of 5°C to 15°C. Default value: 10°C.
CF05 – Type of temperature displayed in AUTO mode
0 | Temperature setting permanent display (default selection) |
1 | Permanent display of the measured room temperature. |
Pressing the + or – button once displays and sets the temperature setting (in ON mode).
CF06 – Regulation time base
15 | 15 minutes (default settings) |
30 | 30 minutes |
45 | 45 minutes |
60 | 60 minutes |
On/Off | On/Off |
CF07 – Modification of the on/off regulation hysteresis Only displayed if menu CF06 = on/off Setting of 0.2°C to 2°C. Default value: 0.4°C CF08 – Anti-seize function The Anti-seize function activates the circulator 1 minute per day to prevent any seizing up during a non-heating period.
0 | Anti-seize disabled |
1 | Anti-seize enabled (default settings) |
CF10 – Return to initial settings
This menu resets all the CF01 to CF09 settings to their default value. By default CF10 = 0. To reset, press + to display 1 and confirm by pressing MODE
COMPATIBLE OPTIONS
Association with a TYDOM home automation box
Your TYBOX 5000 can be used as a connected thermostat, if it is associated with a TYDOM home automation thermostat. Remote control and programming from a tables or smartphone with the TYDOM application.
Association with a door/window magnetic contact (DO / MDO / DOI TYXAL+) If a door/window magnetic contact (e.g. window) is associated with the TYBOX 5000, the heating switches to Frost Protection mode when an open window is detected.
- Press the + and MODE buttons simultaneously until the screen shows for example rF00.
- On the door/window magnetic contact, press the button.
- Check that the screen evolved and shows rF01 on TYBOX 5000.
TROUBLESHOOTING
When you press a button, the screen displays: _ _ _ _ Access to the settings is locked. To unlock, press and hold the + and – buttons for 10 seconds. Important: if you want to lock the device again, refer to the confi guration menu (CF02).
The screen displays the low battery symbol. Replace the batteries The batteries are spent.
Reference
Download Manual:
Delta Dore TYBOX 5000 Room Thermostat Installation Instructions