Danfoss RET2000 Electronic Digital Thermostat With LCD User Guide

Danfoss-logo

Danfoss RET2000 Electronic Digital Thermostat With LCD

Danfoss-RET2000-Electronic-Digital-Thermostat-With-LCD-PRODUCT

What is a room thermostat?

… an explanation for householders. A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators.
Neither does the setting aff ect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.

The heating system will not work if a timeswitch or programmer has switched it off . The way to set and use your room thermostat is to fi nd the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18°C – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have diff erent temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free fl ow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fi res, televisions, wall or table lamps may prevent the thermostat from working properly.

Display

Danfoss-RET2000-Electronic-Digital-Thermostat-With-LCD-FIG.1

The LCD displays actual room temperature until the Λ or V button is pressed more than once. To activate the unit’s backlight pressthe Λ or V button once, if no further buttons are pressed the backlight will remain on for 6 seconds.

Danfoss-RET2000-Electronic-Digital-Thermostat-With-LCD-FIG.2

Setting the temperature

Press either the Λ or V buttons, the product backlight will come on.
Press either the Λ or V button again within 6 seconds, the display will flash with the current set temperature. While the display is flashing press the Λ arrow to increase the set temperature to the required setting or the V arrow to decrease the set temperature.
If no buttons are pressed the display will return to actual temperature after 4 seconds and the backlight will go out after 6 seconds.

Thermostat status (heat mode only)

A flame symbol will be lit whenever the thermostat is calling for heat.

Thermostat status (cool mode only)

A snowfl ake symbol will be lit whenever the thermostat is calling for cooling. If this is seen to fl ash, the thermostat output is delayed for a short period to prevent compressor damage.

Thermostat standby

To place the thermostat into standby (off ), press the V arrow twice to enter the temperature setting mode. When in heating mode press and hold the V arrow until the set temperaturedisappears and the standby symbol appears. In cooling mode press and hold the Λ arrow until the standby symbol appears. When in standby the thermostat will have no control of the heating or cooling system.
To exit standby press and hold the Λ arrow (V arrow in cooling mode) until the required set temperature is fl ashing on the display.

Low Battery Indications (RET2000B)

For battery powered thermostat (RET2000B) when the batteries require replacement the battery low symbol will fl ash. Batteriesshould be replaced within 15 days, after which the thermostat will turn off the load it is controlling. If the power LED does not illuminate when the dial is turned the batteries may have expired and should be replaced immediately to avoid damage to the thermostat

Danfoss-RET2000-Electronic-Digital-Thermostat-With-LCD-FIG.3

Danfoss Ltd Ampthill Road Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Email: [email protected]