Danfoss RET & TP Electronic Room Thermostats Data Sheet-FEATURED

Danfoss RET & TP Electronic Room Thermostats Data Sheet

Danfoss-LOGO

Danfoss RET & TP Electronic Room Thermostats

Danfoss-RET-&-TP-Electronic-Room-Thermostats-PRODUCT

INTRODUCTION

Danfoss-TP5001-Electronic-Room-Thermostats-FIG.1

RET & TP room thermostats are used typically in gas boiler and wall-hung radiator heating systems. They can also be used in other heating systems where reference room temperature is used to switch the heat source either directly or via zone valves.
All the products featured in this datasheet include Load Compensation control to gain more acurate temperature control and improved boiler effiency as well as option to select simply on/off control.
Programmable Room Thermostats, TP5001 The TP5001 adds full heating schedule control to the features offered in the RET variants. By selecting a schedule to suit their daily heating demand the user can significantly reduce cost of heating the home and avoid wasting energy when away from the home or at night. The TP5001 can be set to 5-2Day schedule or 24Hr depending on user preference and if required schedule can be deactivated and the device can be used manually like a room thermostat. 4 event times can be selected (2 heating periods) for morning and evening.

Functions

Room Thermostat, RET1001 By turning the dial to the desired setpoint temperature, optimal thermal comfort in the room is achieved. The thermostat setting scale also includes a frost protect setting allowing for minimal energy consumption while avoiding damage from freezing temperatures and a standby/off position. When a temperature is chosen a green LED confirms that the device is powered and operational. The LED turns red when there is a demand for heat and the output relay is on.
Room Thermostats, RET2001
With RET2001, temperature selection is digital from the setting ring that circles the large easy to read backlit display. Like the dial product RET2001 includes frost protection feature as well as holiday mode with setback temperature for energy saving while you are away.

Additional features

  • Max. and min. temperature limit settings
  • User-selectable frost and holiday temperatures
  • RF Wireless control with the receiver (RF variant only)
  • Optimized and Delayed Start
  • Clock in 12-hour or 24-hour format
  • Service Interval Timer (installer feature only)

The RET & TP room thermostats combine modern design with efficient heating control, ease of operation and high-quality construction to help provide reliable home comfort.

Ordering

Product Type Supply voltage Output Code no.
RET1001M Dial Room Thermostat 230 V AC V/F Relay 087N6460
RET2001M  

Digital Room Thermostats

230 V AC V/F Relay 087N6470
RET2001B 3 V DC V/F Relay 087N6471
RET2001RF+RX1-S 3 V DC* 433.92Mhz RF* 087N7474

* For RF variants supply voltage and output above relates to the thermostat. Each device is supplied with a single channel receiver which requires 230 V AC supply voltage and has a V/F Relay output

Technical specifications

Feature RET1001M RET2001M RET2001B RET2001RF
Type Dial with LED indicator LCD display with push buttons
Setting temperature range 5 – 30° C 5 – 35° C
Operating temperature range 0 – 40° C
Fault indication Yes
LCD backlight Yes
Output Volt free RF 433.92Mhz
Max RF Range in building 30m
Switch rating 3 A (1) at 230Vac
Switch type 1x SPDT Type 1B
Battery life Min 2 years
Power consumption tbc tbc tbc tbc
Power supply 230 V AC ±10 %,

50/60 Hz

3 V DC Battery 2 x AA alkaline)
IP class IP30 (installed)
ErP class Class IV (efficiency gain 2%)
Approval CE marking, EN 60730
Control polution situation Degree 2
Rated impulse voltage 2.5kV
Ball pressure test 75oC
Software classification A

Wiring connections

Danfoss-TP5001-Electronic-Room-Thermostats-FIG.2

Ordering

Product Type Supply voltage Output Code no.
TP5001M Digital Programmable Room Thermostats 230 V AC V/F Relay 087N7930
TP5001B 3 V DC V/F Relay 087N7931
TP5001RF+RX1-S 3 V DC* 433.92Mhz RF* 087N7934

* For RF variants supply voltage and output above relates to the thermostat. Each device is supplied with a single channel receiver which requires 230 V AC supply voltage and has a V/F Relay output.

Technical specifications

Feature TP5001M TP5001B TP5001RF RX1-S
Type LCD display with push buttons RF Receiver
Setting temperature range 5 – 35° C
Operating temperature range 0 – 40° C
Fault indication Yes
LCD backlight Yes
Output Volt free RF 433.92Mhz Volt free
Max RF Range in building 30m
Switch rating 3 A (1) at 230Vac 3 A (1) at 230Vac
Switch type 1x SPDT Type 1B 1x SPDT Type 1B
Battery life Min 2 years
Power consumption tbc tbc tbc tbc
Power supply 230 V AC ±10 %,

50/60 Hz

3 V DC Battery 2 x AA alkaline) 230 V AC ±10 %,

50/60 Hz

IP class IP30 (installed)
ErP class Class IV (efficiency gain 2%)
Approval CE marking, EN 60730
Control polution situation Degree 2
Rated impulse voltage 2.5kV
Ball pressure test 75oC
Software classification A

Wiring connections

Danfoss-TP5001-Electronic-Room-Thermostats-FIG.3

Dimensions

Danfoss-TP5001-Electronic-Room-Thermostats-FIG.4 Danfoss-TP5001-Electronic-Room-Thermostats-FIG.5

Danfoss Limited

Heating Segment
heating.danfoss.co.uk
+44 (0)330 808 6888
E-mail: [email protected]

Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are the property of the respective companies. Danfoss and all Danfoss logotypes are trademarks of Danfoss A/S. All rights reserved.

Danfoss-LOGO

Danfoss RET & TP Electronic Room Thermostats Data Sheet


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *