Danfoss ECtemp 530 Electronic Thermostat
INTRODUCTION
- ECtemp 530/531/532 is a line of simple electronic 15 Amps thermostats with a 2-pole switch for flush-mounted fixing. The thermostats are used to control indoor floor heating systems.
- ECtemp 530 is a 15 Amps thermostat with a wire (floor) sensor, used to control Comfort Floor Heating systems. The thermostat has a dial for adjusting the temperature setting with a numeric scale from
6 (meaning from 5 °C to 45 °C and each step corresponds to approx. 7 °C).
- ECtemp 531 is a 15 Amps thermostat with a built-in air (room) sensor, used to control Direct Floor Heating systems. It has a dial for adjusting the temperature setting with a degree scale from
to 35 °C (meaning from 5 °C to 35 °C).
- ECtemp 532 is a 15 Amps thermostat with a built-in air (room) sensor to control the room temperature and an additional floor (wire) sensor to limit the maximum floor temperature. The thermostat is used to control Direct Heating via Floor systems with the limitation of maximum floor temperature in wooden floors and other heat-sensitive floors. It has a dial for adjusting the room temperature, with a degree scale from to
35 °C (meaning from 5 °C to 35 °C). Adjusting of the maximum floor temperature is provided by a potentiometer placed under the front cover (default 35 °C).
Product specifications
Benefits
• 2-pole safety breaker • Low standby consumption • Sensor failure monitoring • LED indication for fault • Frost protection
Approvals:
Standard compliance • EN/IEC 60730-1 (general) • EN/IEC 60730-2-9 (thermostat) |
Operation voltage | 220 – 240 V, 50/60 Hz |
Standby power consumption | Max. 0,25 W | |
Resistive load | Max 15 A (3450 W) @ 230 V | |
Inductive load | Max. 1 A, cos φ = 0,3 | |
Hysteresis | ± 0,4 °C | |
Sensing unit | NTC 15 kOhm at 25 °C | |
Ambient temperature | -10 °C to +30 °C | |
Frost protection | 5 °C – | |
Cable specification max | 1 x 4 mm2 or 2 x 2,5 mm2 | |
Ball pressure test temperature | 75 °C![]() |
|
Pollution degree | 2 (domestic use) | |
Controller type | 1 C | |
Storage temperature | -20 °C to +65 °C | |
IP class | IP 31 | |
Protection class | Class II – | |
Dimensions (H/W/D) | 85 x 85 x 36 mm | |
Weight | 90 g |
Types
Item no. | Product name | Frame | Temperature range | Sensor type | Marking | EAN no. |
088L0033 | ECtemp 530 | ELKO | 5-45 °C | Wire sensor (3 m, NTC 15 kOhm at 25 °C) | D530 | 5703466128985 |
088L0034 | ECtemp 531 | ELKO | 5-35 °C | Built-in room sensor | D531 | 5703466128992 |
088L0035 |
ECtemp 532 |
ELKO |
5-35 °C room temperature; 20-50 °C floor temperature limiter (default 35 °C) | Built-in room sensor and wire sensor
(3 m, NTC 15 kOhm at 25 °C) |
D532 |
5703466129005 |