Ctc 43355 PROGRAMMABLE THERMOSTAT

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- pro

Introduction

CONGRATULATIONS
Your new Climate Technology electronic thermostat will provide years of reliable service. By saving energy, your thermostat will pay for itself during its first season of use. Thank you for buying a Climate Technology product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, call Climate Technology Technical Support at 800-676-7861 from 8 a.m. to 5 p.m. Central Time

Read This Before Installing Thermostat 

IMPORTANT
Read the entire installation section of this Owner’s Manual thoroughly before you begin to install or operate your Climate Technology Thermostat.

ARMCHAIR PROGRAMMING
You can program your thermostat before installation by inserting the batteries and following the instructions starting on page 16. This can be done while you relax in your favorite chair and is a very good way to familiarize yourself with all the functions of your Climate Technology Thermostat.

OPERATION

Your Thermostat is designed to operate with most gas, oil, electric or 2-wire hot water heating and air conditioning systems. It will also operate single-stage heat pumps that do not have auxiliary or emergency heat. These have 24-volt or millivolt control systems and represent most central heating, air conditioning, or space heating units in use in the United States.

COMPRESSOR PROTECTION
The thermostat provides a 3.5 minute delay after shutting off the heating or cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. Note that this delay also applies to the heating system control. It does not prevent a rapid compressor restart due to short power outages.

TEMPERATURE RANGE
Your thermostat can be programmed between 45°F and 95°F (4°C and 35°C). However, it will display room temperatures from 32°F to 99°F (0°C and 37°C). “HI” will be displayed if the temperature is higher than 99°F (37°C), and “LO” will be displayed if the temperature is lower than 32°F (0°C). This thermostat will automatically cut off in Heat mode if the temperature rises above 95°F (35°C), and automatically cut off in cool mode if the temperature drops below 45°F (7°C).

POWER FAILURE
Whenever the main power is interrupted or fails, the battery power retains the programs and current time.

AUTO RECOVERY
Your thermostat is set from the factory to gradually recover the room temperature from an energy saving program to your comfort program. Therefore, the thermostat may turn your system on several minutes prior to your programmed time. This operation is normal, but can be turned off. Refer to the Selector Switches information on page 24.

BATTERY WARNING
Fresh alkaline batteries should provide over one year of service. However, when the batteries become drained, the Low Battery indicator will flash on the display. When this message occurs, install 2 new AA batteries. You have approximately 1 minute to

ENERGY STAR® Partner
As an ENERGY STAR® Partner, Climate Technology has determined that this programmable thermostat meets the ENERGY STAR® guidelines for energy efficiency. change the batteries and keep thermostat’s clock and program settings. Once the batteries have become too low to ensure proper operation, your system will be turned Off, and the display will be cleared except for the Low Battery indicator flashing on the LCD display.

FeaturesCtc- 43355- PROGRAMMABLE- THERMOSTAT- 1

INSTALLATION

What You Need
This thermostat includes two #8 screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials. Phillips and Slotted Screwdrivers

Remove Old Thermostat

CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully. WIRES MUST BE LABELED PRIOR TO REMOVAL.
IMPORTANT! Turn off the power to the furnace at the main power panel or at the furnace.

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 2

Wire Labeling 

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 3

IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE SELF-ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A ON

If the code letter on your existing thermostat is then mark the wire with label shown and connect to thermostat terminal shownCtc- 43355- PROGRAMMABLE- THERMOSTAT- 4

Mount Wallplate and Thermostat 

Climate Technology wallplate.

Connect Wires and Mount Thermostat Cover to Wall Plate

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 6

Selector Switches

In order for this Climate Technology thermostat to control your system, the system type must be specified by selector switches on the printed circuit board inside the thermostat.

NOTE: When changing these features after installation, move the HEAT / COOL selector switch to OFF before removing the thermostat from the wall.

System Selector Switches:
Heating system selector (HG – HE switch) The factory position for this switch is in the “HG” position. Leave it in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat and Fan come on as expected. If Fan operation is normal, leave the switch in the “HG” position. If the Fan does not come on within a minute of the thermostat calling for Heat, change the switch position to “HE.” The system selector has no effect in the cooling mode.

NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay

Furnace or Heat Pump selector (STD – HP switch)
The factory position for this switch is in the STD position. Leave it in this position if you have ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat Pump (no auxiliary or emergency heat source), then slide the switch to the HP position.

Auto Recovery selector (DISABLE / ENABLE)
Your thermostat is set from the factory with the Auto Recovery Feature enabled, which complies with the EPA ENERGY STAR® Program. If you prefer to use normal recovery, slide the switch to the ALT position. Refer to page 32 for a complete discussion of the Auto Recovery feature.Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 7

Setting Time and Day

12 HR. / 24 HR. TIME FORMAT
Your thermostat is set from the factory in normal 12 (AM / PM) time format. To change to 24 hour (military) time, press program at any time while the Hour, Minute, or Day is flashing to toggle between the 12 hour and 24 hour formats. The AM / PM indicator will not be displayed in 24 hour mode. Both the current time and all programs will automatically change to the selected format.

Default Programs
Studies conducted by the Department of Energy estimate that setting your thermostat back 10°F (6°C) for two 8-hour periods during winter can reduce your fuel bill by as much as 33%. By setting your thermostat up 5°F (3°C) for two 8-hour periods during summer you can reduce your fuel bill up to 25%. Your Climate Technology thermostat is pre-programmed to meet the ENERGY STAR® guidelines for energy efficiency. The thermostat is pre-programmed for all 7 days of the week as shown below

Temperature in F° (C°)
Program Number Time Heat Cool
1 6:00am 68°F (20°C) 78°F (26°C)
2 8:00am 60°F (16°C) 85°F (29°C)
3 4:00pm 68°F (20°C) 78°F (26°C)
4 10:00pm 60°F (16°C) 82°F (28°C)

Personal Program Schedule
Before programming or changing programs, use this Personal Program Schedule to determine which times and temperature settings will best satisfy both your comfort and energy saving requirements Use a pencil so you can revise your records each time you change your temperature settings.

Heating

Day Prog. 1 Prog. 2 Prog. 3 Prog. 4
Mon. Time Temp Time Temp Time Temp Time Temp
Tues. Time Temp Time Temp Time Temp Time Temp
Wed. Time Temp Time Temp Time Temp Time Temp
Thurs. Time Temp Time Temp Time Temp Time Temp
Fri. Time Temp Time Temp Time Temp Time Temp
Sat. Time Temp Time Temp Time Temp Time Temp
Sun. Time Temp Time Temp Time Temp Time Temp

Cooling

Day Prog. 1 Prog. 2 Prog. 3 Prog. 4
Mon. Time Temp Time Temp Time Temp Time Temp
Tues. Time Temp Time Temp Time Temp Time Temp
Wed. Time Temp Time Temp Time Temp Time Temp
Thurs. Time Temp Time Temp Time Temp Time Temp
Fri. Time Temp Time Temp Time Temp Time Temp
Sat. Time Temp Time Temp Time Temp Time Temp
Sun. Time Temp Time Temp Time Temp Time Temp

Manual Programming

NOTE

Weekday/Weekend Programming

7-Day Programming

Reviewing Programs
You may want to review the programs to confirm that the settings are compatible with your lifestyle.

Reviewing the Current Temperature Setting

Temporary Manual Override

To temporarily change the current set temperature without affecting your program:

To end the Temporary Manual Override:

Permanent Manual Override
To hold your Manual Override for vacation or just an extended period of time:

To end the Permanent Manual Override:

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 23Press again. The thermostat will return to the current hold program, and the HOLD display will be canceled.

Vacation Override (Programmable Hold)

This thermostat can hold a fixed temperature for a selected number of days (up to 30). After the selected number of days, the thermostat will return to normal program operation. This feature allows you to return home to your normal comfort setpoint temperatures.

Home Today

This Climate Technology patented feature allows you to quickly and temporarily override your energy saving program setting on days when you are normally away from home with one key press.

Energy Monitor

The Energy monitor feature measures and stores theamount of time the heating and air conditioning system operates. Usage can be displayed for Today (since 12am), Yesterday, This Week (since Monday), Last Week (last Monday through Sunday), and Total (up to 999 Hrs. 59 Min.). By monitoring your energyusage, you see how much the set-back periods are saving and you can test program adjustment to save even more.

Filter Monitor

Auto Recovery
Climate Technology’s Auto Recovery feature meets the ENERGY STAR® guidelines for energy efficiency by allowing the heating or cooling system to recover gradually from an energy-saving setpoint temperature to a comfort setpoint temperature. Auto Recovery calculates how early to turn your system back On, so that the room temperature is already comfortable by the start of the comfort temperature program period. Auto Recovery works in both Heat and Cool modes.

For example, in Heat mode, you could have the following programs:

The room temperature fell to 60°F overnight. Rather than having the thermostat turning on at 6am, Auto Recovery would note the temperature difference between 60°F and 68°F and turn the Heat on approximately 30 minutes early. Therefore, the room temperature at 6am would be about 68°F instead of 60°F. When the thermostat is in Auto Recovery mode, the display will alternate RECO with time, and the program indicator will flashCtc- 43355- PROGRAMMABLE- THERMOSTAT- 43

Details of Auto Recovery Operation:

SPAN Setting Mode

Your thermostat is set at the factory to cycle at 1°F (0.5°C) above and below the set temperature. (Span = 2) This setting has been designed to provide a comfortable room temperature under most all conditions. However, if you find your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time.

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 9Press to raise the Span to 3. This setting INCREASES the cycle time by allowing your system to run LONGER.
Press to lower the Span to 1. This setting DECREASES the cycle time by causing your system to run SHORTER.

Backlighting (INDIGLO® night-light
Your thermostat has an electroluminescent lamp that backlights the display for easy viewing in the dark. When any key is pressed or the System Switch is changed, the display is illuminated. The display will remain illuminated for 5 seconds after the last key is pressed. This allows the light to stay on if you need to operate several keys

SAFETY FEATURES 

Low Battery Warning

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 45Error Mode 

Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 46

Auto Cut Off
Your thermostat will automatically cut-off in Heat mode if the room temperature rises above 95°F (35°C). It will cut-off in Cool mode if the room temperature drops below 40°F (4°C).

Mechanical Heat Back-Up

This thermostat includes a bi-metal switch that will automatically turn on the Heat when the temperature reaches about 41° F (5°C).

TROUBLESHOOTINGCtc- 43355- PROGRAMMABLE- THERMOSTAT- 47 Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 48

WIRING DIAGRAMSCtc- 43355- PROGRAMMABLE- THERMOSTAT- 49 Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 50 Ctc- 43355- PROGRAMMABLE- THERMOSTAT- 51

REFERENCE:

DOWNLOAD MANUALS:

Ctc 43355 PROGRAMMABLE THERMOSTAT Owner’s Manual

CTC-LOGO

Ctc 43355 PROGRAMMABLE THERMOSTAT Owner’s Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)