Carrier ZONECC2KIT01-B Comfort Zone II Zoning System
Models
Comfort Zone II is a zoning system capable of providing zone control requirements for 2, 4, or 8 living or business areas. This system allows the home or business owner to control the living environment in an individualized and energy efficient way. The Comfort Zone II kit includes the User Interface, Equipment Controller, Remote Sensors, an Outdoor Temperature Sensor, and Leaving Air Temperature (LAT) Sensor. Comfort Zone II is the control center for Comfort Heat.
FEATURES/BENEFITS
The auto changeover User Interface has a backlit display. The home or business owner has the option of programming all zones over a 7-day period by following a few simple, well defined steps. The program allows for period, day, and zone functions to be copied, allowing for easier programming.
There are 4 program periods: Wake, Day, Eve, and Sleep. The desired temperature range spans from 40°F to 90°F and there are separate heating and cooling set points. Fully modulating dampers respond to the program as set by the home or business owner and provide enhanced comfort.
Along with a diagnostic error display the User Interface informs the home or business owner when the HVAC system needs to have a filter change. The indoor humidity is also displayed so that comfort can be maximized.
The home or business owner can also control their indoor humidity depending upon the components in their HVAC system. Optional Smart Sensors allow users to adjust temperature settings from the zone. Optional Wireless Sensors allow for easy retrofit installations.
Model number nomenclature
Dimensions
Product data information
Physical Characteristics
- Dimensions: See drawing
- Appearance: Plastic, eggshell color, textured
Electrical Characteristics
- Input Volts/Amps: 24 vac, Less than 40va
Environmental Requirements:
- Operating Temperature/Relative Humidity:
User interface and all sensor types: 32°F to 104°F, 95% rh non-condensing Equipment Controller and wireless receiver: 32°F to 158°F, 95% rh non-condensing - Storage Temperature/Relative Humidity:
User interface and all sensor types: –40°F to 134°F, 95% rh non-condensing Equipment Controller and wireless receiver: –40°F to 185°F, 95% rh non-condensing
Communication:
- Local: RS-485 communication between system components at 9600 baud.
Applications:
- Up to 2 stages cool/3 stages heat
- Dual fuel (Heat pump with gas furnace backup)
Program Specifications:
- Temperature set point range: 40°F to 90°F
- Separate heat and cool set points
- Programming days: 7 day
- Programming periods: 4-Wake, Day, Eve, Sleep
- Auto changeover (may be disabled)
- Programmable fan (Installer selectable)
- Humidity Sensor Offsets
- Auto Changeover Timer (installer adjustable)
- Smart Recovery (in heating and cooling)
- Clean filter reminder (installer adjustable)
- Hold function
- Copy functions: Copy period, day and zone
- Permanent memory
- Humidity display and control
- Temperature sensor offsets (indoor and outdoor)
Wiring Requirements:
- Power supply: Dedicated 24 vac, 40 va, 60 hz isolated transformer, field supplied.
- Wiring material: Standard thermostat wire 18 to 24 gage.
- Equipment Controller to User Interface: 4 wires
- Equipment Controller to Remote Sensors: 2 wires Equipment Controller to Smart Sensors: 4 wires
- Equipment Controller to Dampers: 3 wires
- Equipment Controller to LAT/HPT Sensor: 2 wires Equipment Controller to Outdoor Temperature Sensor: 2 wires
Comfort Zone II Kit
DESCRIPTION | PART NO. |
Equipment controller, user interface, duct sensor, outdoor temperature sensor, 1 room sensor | ZONECC2KIT01-B |
Equipment controller, user interface, duct sensor, outdoor temperature sensor, 3 room sensors | ZONECC4KIT01-B |
Equipment controller, user interface, duct sensor, outdoor temperature sensor, 7 room sensors | ZONECC8KIT01-B |
OPTIONAL ACCESSORIES
DESCRIPTION | PART NO. |
Wireless Remote Room Sensor | ZONECC0WRS01 |
Wireless Receiver (1 required per wireless application) | ZONECC0WRC01 |
Smart Sensor | ZONECC0SMS01 |
LAT/HPT Sensor (An additional sensor is required for heat pump applications) | ZONEXX0DTS01 |
Multi-Damper Enabler* | ZONEMLTDMPEN |
Must be used with earlier style dampers (Series A, B, or C), or if more than 3 dampers are used in a single zone.
REPLACEMENT ACCESSORIES
DESCRIPTION | PART NO. |
Remote Room Sensor (wired) | ZONECC0RRS01 |
Equipment Controller — 2 Zone | ZONECC2EQC01 |
Equipment Controller — 4 Zone | ZONECC4EQC01 |
Equipment Controller — 8 Zone | ZONECC8EQC01 |
User Interface | ZONECC0USI01-B |
Outdoor Temperature Sensor* | TSTATXXSEN01-B |
Must be used in dual fuel applications, or if automatically adjusting the humidity set points in humidification applications.
Accessories
DAMPERS
DESCRIPTION | PART NO. | |
Round Dampers |
6 in. | DAMPRND06INC |
8 in. | DAMPRND08INC | |
10 in. | DAMPRND10INC | |
12 in. | DAMPRND12INC | |
14 in. | DAMPRND14INC | |
16 in. | DAMPRND16INC | |
Rectangular Dampers |
8 in. X 10 in. | DAMPREC08X10 |
8 in. X 14 in. | DAMPREC08X14 | |
8 in. X 18 in. | DAMPREC08X18 | |
8 in. X 24 in. | DAMPREC08X24 | |
10 in. X 10 in. | DAMPREC10X10 | |
10 in. X 14 in. | DAMPREC10X14 | |
10 in. X 18 in. | DAMPREC10X18 | |
10 in. X 24 in. | DAMPREC10X24 | |
Round Barometric Bypass |
8 in. | DAMPBAR08INC |
10 in. | DAMPBAR10INC | |
12 in. | DAMPBAR12INC | |
14 in. | DAMPBAR14INC | |
16 in. | DAMPBAR16INC | |
Rectangular Barometric Bypass | 8 in. X 14 in. | DAMPBAR08X14 |
8 in. X 24 in. | DAMPBAR08X24 | |
Slip-In Dampers |
Side mount, 8 X 10 | DAMPSLS08X10 |
Bottom mount, 8 X 10 | DAMPSLB08X10 | |
Side mount, 8 X 12 | DAMPSLS08X12 | |
Bottom mount, 8 X 12 | DAMPSLB08X12 | |
Side mount, 8 X 14 | DAMPSLS08X14 | |
Bottom mount, 8 X 14 | DAMPSLB08X14 | |
Side mount, 8 X 16 | DAMPSLS08X16 | |
Bottom mount, 8 X 16 | DAMPSLB08X16 | |
Side mount, 8 X 18 | DAMPSLS08X18 | |
Bottom mount, 8 X 18 | DAMPSLB08X18 | |
Bottom mount, 8 X 20 | DAMPSLB08X20 | |
Bottom mount, 8 X 22 | DAMPSLB08X22 | |
Bottom mount, 8 X 24 | DAMPSLB08X24 | |
Side mount, 10 X 10 | DAMPSLS10X10 | |
Bottom mount, 10 X 10 | DAMPSLB10X10 | |
Side mount, 10 X 12 | DAMPSLS10X12 | |
Bottom mount, 10 X 12 | DAMPSLB10X12 | |
Side mount, 10 X 14 | DAMPSLS10X14 | |
Bottom mount, 10 X 14 | DAMPSLB10X14 | |
Side mount, 10 X 16 | DAMPSLS10X16 | |
Bottom mount, 10 X 16 | DAMPSLB10X16 | |
Side mount, 10 X 18 | DAMPSLS10X18 | |
Bottom mount, 10 X 18 | DAMPSLB10X18 | |
Bottom mount, 10 X 20 | DAMPSLB10X20 | |
Bottom mount, 10 X 22 | DAMPSLB10X22 | |
Bottom mount, 10 X 24 | DAMPSLB10X24 | |
Bottom mount, 14 X 20 | DAMPSLB14X20 | |
Replacement Actuators | 90° for rectangular dampers | DAMPACT90DEG |
45° for round dampers | DAMPACT45DEG |
NOTE: The above dampers are recommended because they use the latest style actuators designed for zoning systems. These actuators are direct-drive and use slightly less power to operate. If using older style dampers with this zoning system (ie., dampers with a crankarm), it is recommended to upgrade the actuator to DAMPACT45DEG, or DAMPACT90DEG.
Copyright 1999 Carrier Corporation • Indianapolis, IN 46231 8-99
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
References:
Download Manual